Copper Core Medium Voltage XLPE Insulated Power Cable

China 
                        Copper Core Medium Voltage XLPE Insulated Power Cable
                      manufacture and supplier

Copper Core Medium Voltage XLPE Insulated Power Cable image

Get Latest Price Request a quote

Quick Details

Copper Core Medium Voltage XLPE Insulated Power Cable

xlpe cable

Henan Jiapu

ISO, CE, SABS

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Underground

0.6/1 Kv 3.6/6 Kv

1-5 Cores

IEC60502 IEC60331 DIN BS

90 Degrees

250 Degrees

Jiapu

Wooden Drum or Wooden&Steel Drum

IEC ASTM BS DIN, Any standard

Henan, China

8544601200

Product Details

 Copper Core Medium Voltage XLPE Insulated Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:

Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 2.5 0.12 1.5 17.6 0.34 0.49 1.2000 0.7270
35 7.0 2.5 0.12 1.5 18.5 0.39 0.60 0.8680 0.5240
50 8.3 2.5 0.12 1.6 20.0 0.46 0.74 0.6410 0.3870
70 9.7 2.5 0.12 1.6 21.5 0.55 0.96 0.4430 0.2680
95 11.3 2.5 0.12 1.7 23.3 0.66 1.23 0.3200 0.1930
120 13 2.5 0.12 1.7 24.8 0.77 1.48 0.2530 0.1530
150 14.6 2.5 0.12 1.8 26.4 0.87 1.77 0.2060 0.1240
185 15.9 2.5 0.12 1.8 28.1 1.01 2.13 0.1640 0.0991
240 18.3 2.6 0.12 1.9 30.9 1.23 2.71 0.1250 0.0754
300 20.4 2.8 0.12 2.0 33.6 1.48 3.32 0.1000 0.0601
400 23.2 3.0 0.12 2.1 37.0 1.81 4.16 0.0778 0.0470
500 26.4 3.2 0.12 2.2 41.1 2.24 5.27 0.0605 0.0366
630 30.1 3.2 0.12 2.3 45.0 2.73 6.62 0.0469 0.0283

2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 3.4 0.12 1.5 19.4 0.40 0.55 1.2000 0.7270
35 6.9 3.4 0.12 1.6 20.5 0.45 0.66 0.8680 0.5240
50 8.2 3.4 0.12 1.6 21.8 0.52 0.80 0.6410 0.3870
70 9.7 3.4 0.12 1.7 23.5 0.62 1.03 0.4430 0.2680
95 11.3 3.4 0.12 1.7 25.1 0.73 1.30 0.3200 0.1930
120 12.8 3.4 0.12 1.8 26.8 0.85 1.56 0.2530 0.1530
150 14.2 3.4 0.12 1.8 28.2 0.95 1.85 0.2060 0.1240
185 15.9 3.4 0.12 1.9 30.1 1.10 2.22 0.1640 0.0991
240 18.3 3.4 0.12 2.0 32.7 1.33 2.80 0.1250 0.0754
300 20.4 3.4 0.12 2.0 34.8 1.54 3.39 0.1000 0.0601
400 23.2 3.4 0.12 2.2 38.0 1.87 4.22 0.0778 0.0470
500 26.4 3.4 0.12 2.2 41.5 2.26 5.29 0.0605 0.0366
630 30.1 3.4 0.12 2.4 45.6 2.78 6.67 0.0469 0.0283

3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 4.5 0.12 1.6 21.8 0.48 0.63 1.2000 0.7270
35 6.9 4.5 0.12 1.7 22.9 0.54 0.75 0.8680 0.5240
50 8.2 4.5 0.12 1.7 24.2 0.61 0.89 0.6410 0.3870
70 9.7 4.5 0.12 1.8 25.9 0.72 1.13 0.4430 0.2680
95 11.3 4.5 0.12 1.8 27.5 0.84 1.40 0.3200 0.1930
120 12.8 4.5 0.12 1.9 29.2 0.96 1.67 0.2530 0.1530
150 14.2 4.5 0.12 1.9 30.6 1.06 1.96 0.2060 0.1240
185 15.9 4.5 0.12 2.0 32.5 1.22 2.34 0.1640 0.0991
240 18.3 4.5 0.12 2.1 35.1 1.46 2.93 0.1250 0.0754
300 20.4 4.5 0.12 2.1 37.2 1.68 3.52 0.1000 0.0601
400 23.2 4.5 0.12 2.2 40.2 2.00 4.35 0.0778 0.0470
500 26.4 4.5 0.12 2.3 43.9 2.43 5.45 0.0605 0.0366
630 30.1 4.5 0.12 2.4 47.8 2.93 6.83 0.0469 0.0283

4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25                  
35 6.9 5.5 0.12 1.7 24.9 0.62 0.83 0.8680 0.5240
50 8.2 5.5 0.12 1.8 26.4 0.70 0.98 0.6410 0.3870
70 9.7 5.5 0.12 1.8 27.9 0.80 1.21 0.4430 0.2680
95 11.3 5.5 0.12 1.9 29.7 0.94 1.50 0.3200 0.1930
120 12.8 5.5 0.12 1.9 31.2 1.05 1.77 0.2530 0.1530
150 14.2 5.5 0.12 2.0 32.8 1.17 2.07 0.2060 0.1240
185 15.9 5.5 0.12 2.0 34.5 1.33 2.45 0.1640 0.0991
240 18.3 5.5 0.12 2.1 37.1 1.57 3.04 0.1250 0.0754
300 20.4 5.5 0.12 2.2 39.4 1.81 3.66 0.1000 0.0601
400 23.2 5.5 0.12 2.3 42.4 2.14 4.49 0.0778 0.0470
500 26.4 5.5 0.12 2.4 46.1 2.58 5.61 0.0605 0.0366
630 30.1 5.5 0.12 2.4 49.8 3.10 6.99 0.0469 0.0283

5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25                  
35                  
50 8.2 8.0 0.12 2.0 31.8 0.95 1.23 0.6410 0.3870
70 9.7 8.0 0.12 2.0 33.3 1.07 1.47 0.4430 0.2680
95 11.3 8.0 0.12 2.1 35.1 1.21 1.78 0.3200 0.1930
120 12.8 8.0 0.12 2.1 36.6 1.34 2.05 0.2530 0.1530
150 14.2 8.0 0.12 2.2 38.2 1.47 2.37 0.2060 0.1240
185 15.9 8.0 0.12 2.2 39.9 1.64 2.76 0.1640 0.0991
240 18.3 8.0 0.12 2.3 42.5 1.90 3.37 0.1250 0.0754
300 20.4 8.0 0.12 2.4 44.8 2.16 4.01 0.1000 0.0601
400 23.2 8.0 0.12 2.4 47.6 2.52 4.87 0.0778 0.0470
500 26.4 8.0 0.12 2.5 51.3 2.98 6.01 0.0605 0.0366
630 30.1 8.0 0.12 2.6 55.2 3.54 7.43 0.0469 0.0283

6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 2.5 0.1 2.0 34.6 1.13 1.58 1.2000 0.7270
35 6.9 2.5 0.1 2.1 36.8 1.29 1.92 0.8680 0.5240
50 8.2 2.5 0.1 2.2 39.8 1.51 2.36 0.6410 0.3870
70 9.7 2.5 0.1 2.3 43.2 1.81 3.04 0.4430 0.2680
95 11.3 2.5 0.1 2.4 46.9 2.17 3.87 0.3200 0.1930
120 12.8 2.5 0.1 2.4 50.1 2.53 4.69 0.2530 0.1530
150 14.2 2.5 0.1 2.5 53.3 2.90 5.60 0.2060 0.1240
185 15.9 2.5 0.1 2.6 57.2 3.40 6.77 0.1640 0.0991
240 18.3 2.6 0.1 2.8 63.2 4.12 8.55 0.1250 0.0754
300 20.4 2.8 0.1 3.0 69.0 4.89 10.46 0.1000 0.0601
400 23.2 3.0 0.1 3.4 76.7 6.10 13.18 0.0778 0.0470
500 26.4 3.2 0.1 3.6 85.7 8.10 16.55 0.0605 0.0366

7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 3.4 0.1 2.1 38.7 1.30 1.75 1.2000 0.7270
35 6.9 3.4 0.1 2.2 40.9 1.47 2.22 0.8680 0.5240
50 8.2 3.4 0.1 2.3 43.9 1.70 2.50 0.6410 0.3870
70 9.7 3.4 0.1 2.4 47.3 2.02 3.25 0.4430 0.2680
95 11.3 3.4 0.1 2.5 51.0 2.42 4.12 0.3200 0.1930
120 12.8 3.4 0.1 2.6 54.4 2.79 4.95 0.2530 0.1530
150 14.2 3.4 0.1 2.7 57.6 3.17 5.87 0.2060 0.1240
185 15.9 3.4 0.1 2.8 61.5 3.69 7.06 0.1640 0.0991
240 18.3 3.4 0.1 2.9 66.9 4.38 8.82 0.1250 0.0754
300 20.4 3.4 0.1 3.1 71.8 5.11 10.68 0.1000 0.0601
400 23.2 3.4 0.1 3.3 78.3 6.24 13.32 0.0778 0.0470
500 26.4 3.4 0.1 3.5 86.4 7.63 16.50 0.0605 0.0366

8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 4.5 0.1 2.3 43.9 1.57 2.02 0.9270 0.7270
35 6.9 4.5 0.1 2.4 46.0 1.75 2.38 0.6680 0.5240
50 8.2 4.5 0.1 2.4 48.8 2.00 2.85 0.4936 0.3870
70 9.7 4.5 0.1 2.5 52.3 2.34 3.57 0.3420 0.2680
95 11.3 4.5 0.1 2.6 55.9 2.75 4.45 0.2464 0.1930
120 12.8 4.5 0.1 2.7 59.4 3.16 5.32 0.1955 0.1530
150 14.2 4.5 0.1 2.8 62.6 3.57 6.27 0.1587 0.1240
185 15.9 4.5 0.1 2.9 66.4 4.07 7.45 0.1271 0.0991
240 18.3 4.5 0.1 3.1 72.0 4.82 9.25 0.0976 0.0754
300 20.4 4.5 0.1 3.3 77.0 5.71 11.28 0.0778 0.0601
400 23.2 4.5 0.1 3.4 83.2 6.78 13.86 0.0615 0.0470
500 26.4 4.5 0.1 3.5 91.1 8.20 17.32 0.0487 0.0366

9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm2 mm mm kg/m kg/m Ω/km Ω/km
25                
35 6.9 5.5 0.1 2.4 50.3 2.00 2.63 0.8680 0.6680
50 8.2 5.5 0.1 2.5 53.3 2.26 3.11 0.6410 0.4936
70 9.7 5.5 0.1 2.6 56.8 2.62 3.85 0.4430 0.3420
95 11.3 5.5 0.1 2.8 60.6 3.07 4.77 0.3200 0.2464
120 12.8 5.5 0.1 2.9 64.1 3.49 5.65 0.2530 0.1955
150 14.2 5.5 0.1 3.0 67.3 3.91 6.61 0.2060 0.1587
185 15.9 5.5 0.1 3.1 71.2 4.44 7.81 0.1640 0.1271
240 18.3 5.5 0.1 3.3 76.8 5.21 9.64 0.1250 0.0976
300 20.4 5.5 0.1 3.3 81.3 6.10 11.66 0.1000 0.0778
400 23.2 5.5 0.1 3.5 87.7 7.20 14.28 0.0778 0.0615
500 26.4 5.5 0.1 3.8 96.0 9.15 17.80 0.0605 0.0487

10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25                  
35                  
50 8.2 8.0 0.1 2.9 64.9 3.02 3.87 0.6410 0.4936
70 9.7 8.0 0.1 3.0 68.4 3.42 4.65 0.4430 0.3420
95 11.3 8.0 0.1 3.1 72.0 3.89 5.59 0.3200 0.2464
120 12.8 8.0 0.1 3.3 75.7 4.39 6.54 0.2530 0.1955
150 14.2 8.0 0.1 3.3 78.7 4.85 7.55 0.2060 0.1587
185 15.9 8.0 0.1 3.4 82.6 5.42 8.79 0.1640 0.1271
240 18.3 8.0 0.1 3.5 88.0 6.22 10.66 0.1250 0.0976
300 20.4 8.0 0.1 3.7 92.9 7.20 12.77 0.1000 0.0778
400 23.2 8.0 0.1 3.9 99.3 8.38 15.46 0.0778 0.0615
500 26.4 8.0 0.1 4.2 107.6 10.15 18.85 0.0605 0.0487

We are China Copper Core Medium Voltage XLPE Insulated Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular jpcable99 Products

300mm2 Steel Tape Armoured Power Cable

Low Voltage PVC Insulated 4 Core Power Cable

High Performance Electrical Wire for House Use

Aluminum Conductor Triplex Service Drop Aerial Bundled Cable

Icea Approved Aluminum Conductor XLPE Insulated Wire ABC Cable

High Quality 1/11kv XLPE Insulated Steel Wire Armoured Cable

Popular Power Cable Products

70mm 95mm 120mm XLPE Insulated PVC Sheathed Copper Power Wire

Building Wire, Flexible Cable, Cable

4 Core 185 Sqmm with Earth 95 mm2 1kv Armoured Electrical Cable Steel Tape Armord XLPE Copper Cable

3 Core Copper Conductor Low Voltage XLPE Insulated Power Cable

0.6/1kv Copper Conductor XLPE Insulated PVC Sheathed Power Cable

35sqmm 50sqmm 70sqmm Ml XLPE Insulated Power Cable

Popular XLPE Insulated Power Cable Products

Cu Core XLPE Insulated Steel Wire Armored Power Cable

1kv Copper Conductor XLPE Insulated 3X2.5mm2 Power Cable

3+1-Core Cu/Al XLPE Insulation PVC Sheath Power Cable

XLPE /PVC (Cross-linked polyethylene) Insulated Electric Power Cable

Medium Voltage Power Cable, Swa Armour Cable 3X240mm2

0.6/1kv XLPE Insulated PVC Sheath Swa Power Cable

Popular XLPE Power Cable Products

Power Cable XLPE Insulated Suitable for 15kw Generator

Kable Na2xs (F) 2y N2xseyby N2xsyry Medium Voltage Power Cable N2xy Cable

XLPE/PVC Insulated, PVC Sheathed, Aluminum/Copper Power Cable for Construction

Copper Aluminum Conductor XLPE/PVC Insulated Electric Power Cable

Underground Cable Steel Wire/Type Armoured Copper Power Cable

PVC Insulation Stainless Steel Tape Armoured Electrical Cable One Core Low Voltage Aluminum Cable