Copper Core PVC Insulated and Sheathed VV Power Cable
Copper Core PVC Insulated and Sheathed VV Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Unarmoured |
Armoured |
||||||||
|
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
Thickness of Bedding |
Thickness of Al Tape |
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
|||||
|
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||||
|
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
|
1.5 |
1 |
0.8 |
1.4 |
5.8 |
– |
51 |
– |
– |
– |
– |
– |
– |
|
2.5 |
1 |
0.8 |
1.4 |
6.2 |
– |
64 |
– |
– |
– |
– |
– |
– |
|
4 |
1 |
1 |
1.4 |
7.1 |
– |
88 |
– |
– |
– |
– |
– |
– |
|
6 |
7 |
1 |
1.4 |
7.8 |
78 |
114 |
– |
– |
– |
– |
– |
– |
|
10 |
7 |
1 |
1.4 |
8.6 |
96 |
159 |
1 |
0.5 |
1.8 |
13.4 |
234 |
295 |
|
16 |
7 |
1 |
1.4 |
9.6 |
123 |
222 |
1 |
0.5 |
1.8 |
14.4 |
274 |
370 |
|
25 |
7 |
1.2 |
1.4 |
11.2 |
172 |
328 |
1 |
0.5 |
1.8 |
16 |
344 |
496 |
|
35 |
7 |
1.2 |
1.4 |
12.2 |
209 |
428 |
1 |
0.5 |
1.8 |
17 |
393 |
606 |
|
50 |
19 |
1.4 |
1.4 |
13.9 |
271 |
565 |
1 |
0.5 |
1.8 |
18.7 |
478 |
764 |
|
70 |
19 |
1.4 |
1.5 |
15.9 |
356 |
818 |
1 |
0.5 |
1.8 |
20.5 |
582 |
1020 |
|
95 |
19 |
1.6 |
1.5 |
18 |
471 |
1041 |
1 |
0.5 |
1.8 |
22.6 |
717 |
1291 |
|
120 |
37 |
1.6 |
1.6 |
19.6 |
563 |
1307 |
1 |
0.5 |
1.8 |
24 |
822 |
1545 |
|
150 |
37 |
1.8 |
1.6 |
21.3 |
684 |
1592 |
1 |
0.5 |
1.8 |
25.4 |
952 |
1857 |
|
185 |
37 |
2 |
1.7 |
23.9 |
840 |
1985 |
1 |
0.5 |
1.8 |
27.9 |
1136 |
2236 |
|
240 |
61 |
2.2 |
1.8 |
27 |
1071 |
2533 |
1 |
0.5 |
1.9 |
31 |
1404 |
2877 |
|
300 |
61 |
2.4 |
1.9 |
29.6 |
1317 |
3162 |
1.2 |
0.5 |
2.1 |
34.3 |
1722 |
3551 |
|
400 |
61 |
2.6 |
2 |
33.2 |
1666 |
4120 |
1.2 |
0.5 |
2.2 |
37.6 |
2114 |
4488 |
|
500 |
61 |
2.8 |
2.2 |
37.5 |
2089 |
5163 |
1.2 |
0.5 |
2.3 |
42.1 |
2592 |
5683 |
|
630 |
61 |
2.8 |
2.3 |
41.2 |
2581 |
6447 |
1.4 |
0.5 |
2.4 |
46.3 |
3184 |
7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
|
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|
|
Al Conductor |
Cu Conductor |
||||||
|
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
Three Cores |
3×35 |
16 |
1.2 |
1.8 |
21.9 |
601 |
1280 |
|
3×50 |
18 |
1.4 |
1.8 |
26.5 |
829 |
1732 |
|
|
3×70 |
18 |
1.4 |
1.9 |
29.2 |
1067 |
2367 |
|
|
3×95 |
36 |
1.6 |
2 |
32.9 |
1409 |
2317 |
|
|
3×120 |
36 |
1.6 |
2.1 |
36.2 |
1705 |
3983 |
|
|
3×150 |
36 |
1.8 |
2.2 |
38.8 |
2045 |
4872 |
|
|
3×185 |
36 |
2 |
2.4 |
44.8 |
2596 |
6077 |
|
|
3×240 |
60 |
2.2 |
2.6 |
51.5 |
3353 |
7953 |
|
|
3×300 |
60 |
2.4 |
2.7 |
54.9 |
6069 |
9820 |
|
|
Four Cores with Reduced Neutral |
3×35+16 |
16-7 |
1.2-1 |
1.8 |
25.5 |
764 |
1107 |
|
3×50+25 |
18-16 |
1.4-1.2 |
1.9 |
28.7 |
982 |
1410 |
|
|
3×70+35 |
18-16 |
1.4-1.2 |
2.0 |
32 |
1278 |
1733 |
|
|
3×95+50 |
36-18 |
1.6-1.4 |
2.2 |
37.8 |
1711 |
2656 |
|
|
3×120+70 |
36-18 |
1.6-1.4 |
2.3 |
40.5 |
2065 |
3137 |
|
|
3×150+70 |
36-18 |
1.8-1.4 |
2.4 |
44.8 |
2480 |
3660 |
|
|
3×185+95 |
36-36 |
2-1.6 |
2.6 |
49.7 |
3086 |
4345 |
|
|
3×240+120 |
60-36 |
2.2-1.6 |
2.8 |
56 |
3894 |
5441 |
|
|
3×300+150 |
60-36 |
1.4-1.8 |
2.9 |
60.3 |
4834 |
6494 |
|
|
Four Cores |
4×25 |
16 |
1.2 |
1.8 |
22.5 |
644 |
1286 |
|
4×35 |
16 |
1.2 |
1.8 |
24.6 |
799 |
1696 |
|
|
4×50 |
18 |
1.4 |
1.8 |
28.6 |
1071 |
2275 |
|
|
4×70 |
18 |
1.4 |
2 |
31.6 |
1387 |
3120 |
|
|
4×95 |
36 |
1.6 |
2.1 |
35.9 |
1850 |
4262 |
|
|
4×120 |
36 |
1.6 |
2.2 |
38.8 |
2209 |
5247 |
|
|
4×150 |
36 |
1.8 |
2.3 |
43.1 |
2714 |
6483 |
|
|
4×185 |
36 |
2 |
2.5 |
48.7 |
3403 |
8045 |
|
|
4×240 |
60 |
2.2 |
2.7 |
53.6 |
4290 |
10422 |
|
|
4×300 |
60 |
2.4 |
2.9 |
58.8 |
5302 |
12969 |
|
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
|
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||
|
Al Conductor |
Cu Conductor |
|||||||
|
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
|
Three Cores |
3×10 |
7 |
1 |
1.8 |
16.6 |
281 |
465 |
|
|
3×16 |
7 |
1 |
1.8 |
18.7 |
387 |
679 |
||
|
3×25 |
7 |
1.2 |
1.8 |
22.2 |
536 |
996 |
||
|
3×35 |
7 |
1.2 |
1.8 |
24.4 |
665 |
1311 |
||
|
3×50 |
19 |
1.4 |
1.9 |
28.1 |
863 |
1729 |
||
|
3×70 |
19 |
1.4 |
2 |
32.3 |
1153 |
2480 |
||
|
3×95 |
19 |
1.6 |
2.1 |
37.1 |
1563 |
3301 |
||
|
3×120 |
37 |
1.6 |
2.3 |
40.4 |
1850 |
4040 |
||
|
3×150 |
37 |
1.8 |
2.4 |
43.9 |
2258 |
5000 |
||
|
3×185 |
37 |
2 |
2.5 |
49.2 |
2819 |
6151 |
||
|
3×240 |
61 |
2.2 |
2.8 |
55.9 |
3577 |
8040 |
||
|
3×300 |
61 |
2.4 |
3 |
62.1 |
4413 |
9955 |
||
|
3×400 |
61 |
2.6 |
3.2 |
69.3 |
5512 |
12705 |
||
|
Four Cores |
4×10 |
7 |
1 |
1.8 |
18.1 |
343 |
589 |
|
|
4×16 |
7 |
1 |
1.8 |
20.5 |
487 |
874 |
||
|
4×25 |
7 |
1.2 |
1.8 |
24.3 |
677 |
1291 |
||
|
4×35 |
7 |
1.2 |
1.8 |
26.8 |
821 |
1681 |
||
|
4×50 |
19 |
1.4 |
2 |
31.2 |
1118 |
2273 |
||
|
4×70 |
19 |
1.4 |
2.1 |
35.8 |
1494 |
3264 |
||
|
4×95 |
19 |
1.6 |
2.3 |
41.2 |
1993 |
4312 |
||
|
4×120 |
37 |
1.6 |
2.4 |
44.8 |
2370 |
5291 |
||
|
4×150 |
37 |
1.8 |
2.5 |
48.7 |
2959 |
6615 |
||
|
4×185 |
37 |
2 |
2.7 |
54.7 |
3601 |
8044 |
||
|
4×240 |
61 |
2.2 |
3 |
62.1 |
4596 |
10547 |
||
|
4×300 |
61 |
2.4 |
3.2 |
69.1 |
5614 |
13004 |
||
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||||||
|
STA |
SWA |
|||||||||||||
|
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||
|
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
|
Three Cores |
||||||||||||||
|
3×35 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
24.7 |
28.2 |
912 |
1591 |
1447 |
2126 |
|
|
3×50 |
18 |
1.4 |
1 |
0.2 |
46/1.6 |
1.9 |
2 |
29.3 |
32.8 |
1202 |
2105 |
1842 |
2745 |
|
|
3×70 |
18 |
1.4 |
1.2 |
0.2 |
41/2.0 |
2.0 |
2.2 |
32.5 |
37.1 |
1520 |
2820 |
2475 |
3775 |
|
|
3×95 |
36 |
1.6 |
1.2 |
0.5 |
46/2.0 |
2.1 |
2.3 |
36.5 |
40.8 |
2241 |
4049 |
2989 |
4797 |
|
|
3×120 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.2 |
2.4 |
39.8 |
44.1 |
2617 |
4895 |
3435 |
5713 |
|
|
3×150 |
36 |
1.8 |
1.2 |
0.5 |
43/2.5 |
2.3 |
2.5 |
42.4 |
47.8 |
3019 |
5846 |
4258 |
7085 |
|
|
3×185 |
36 |
2 |
1.4 |
0.5 |
50/2.5 |
2.5 |
2.7 |
48.8 |
54.2 |
3783 |
7264 |
5219 |
8700 |
|
|
3×240 |
60 |
2.2 |
1.6 |
0.5 |
58/2.5 |
2.8 |
2.9 |
56 |
61.3 |
4790 |
9390 |
6444 |
11044 |
|
|
3×300 |
60 |
2.4 |
1.6 |
0.5 |
61/2.5 |
2.9 |
3.1 |
59.3 |
64.7 |
5594 |
11345 |
7458 |
13209 |
|
|
Four Cores with Reduced Neutral |
||||||||||||||
|
3×35+16 |
16-7 |
1.2-1 |
1 |
0.2 |
43/1.6 |
1.9 |
2 |
28.5 |
31.3 |
1107 |
1528 |
1705 |
2469 |
|
|
3×50+25 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
40/2.0 |
2.0 |
2.1 |
32.2 |
36.1 |
1410 |
2044 |
2326 |
3388 |
|
|
3×70+35 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
44/2.0 |
2.0 |
2.2 |
35.2 |
39.3 |
1733 |
2801 |
2762 |
4285 |
|
|
3×95+50 |
36-18 |
1.6-1.4 |
1.2 |
0.5 |
41/2.5 |
2.3 |
2.5 |
42.5 |
46.3 |
2656 |
3820 |
3816 |
5925 |
|
|
3×120+70 |
36-18 |
1.6-1.4 |
1.4 |
0.5 |
45/2.5 |
2.4 |
2.6 |
45.6 |
49.4 |
3137 |
4777 |
4391 |
7103 |
|
|
3×150+70 |
36-18 |
1.8-1.4 |
1.4 |
0.5 |
49/2.5 |
2.6 |
2.7 |
49.9 |
53.6 |
3660 |
5709 |
5043 |
8272 |
|
|
3×185+95 |
36-36 |
2-1.6 |
1.4 |
0.5 |
55/2.5 |
2.6 |
2.9 |
54.5 |
58.5 |
3445 |
7171 |
5902 |
9987 |
|
|
3×240+120 |
60-36 |
2.2-1.6 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3.1 |
61.6 |
65.3 |
5441 |
9272 |
7174 |
12552 |
|
|
3×300+150 |
60-36 |
1.4-1.8 |
1.6 |
0.5 |
67/2.5 |
3.8 |
3.2 |
65.9 |
69.6 |
6494 |
11546 |
8355 |
15067 |
|
|
Four Cores |
||||||||||||||
|
4×25 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
25.3 |
28 |
934 |
1576 |
1450 |
2092 |
|
|
4×35 |
16 |
1.2 |
1 |
0.2 |
41/1.6 |
1.8 |
1.9 |
27.4 |
30.2 |
1120 |
2017 |
1681 |
2578 |
|
|
4×50 |
18 |
1.4 |
1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.6 |
35.6 |
1454 |
2658 |
2336 |
3540 |
|
|
4×70 |
18 |
1.4 |
1.2 |
0.5 |
43/2.0 |
2.1 |
2.2 |
36.3 |
39 |
2183 |
3916 |
2840 |
4573 |
|
|
4×95 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.4 |
40.6 |
44.1 |
2748 |
5160 |
3545 |
5957 |
|
|
4×120 |
36 |
1.6 |
1.4 |
0.5 |
42/2.5 |
2.4 |
2.5 |
43.9 |
47.2 |
3237 |
6214 |
4334 |
7372 |
|
|
4×150 |
36 |
1.8 |
1.4 |
0.5 |
48/2.5 |
2.5 |
2.6 |
48.3 |
52 |
3853 |
7622 |
5148 |
8917 |
|
|
4×185 |
36 |
2 |
1.6 |
0.5 |
54/2.5 |
2.7 |
2.8 |
54.3 |
57.6 |
4756 |
9323 |
6132 |
10774 |
|
|
4×240 |
60 |
2.2 |
1.6 |
0.5 |
59/2.5 |
2.9 |
3 |
59.2 |
62.9 |
5774 |
11906 |
7374 |
13506 |
|
|
4×300 |
60 |
2.4 |
1.6 |
0.5 |
65/2.5 |
3 |
3.2 |
64.3 |
68.1 |
6922 |
14589 |
8624 |
16291 |
|
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|||||
|
STA |
SWA |
||||||||||||
|
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||
|
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
Three Cores |
|||||||||||||
|
3×10 |
7 |
1 |
1 |
0.2 |
35/1.25 |
1.8 |
1.8 |
19.4 |
21.5 |
494 |
679 |
988 |
1172 |
|
3×16 |
7 |
1 |
1 |
0.2 |
32/1.6 |
1.8 |
1.8 |
21.5 |
24.3 |
604 |
895 |
1051 |
1343 |
|
3×25 |
7 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.8 |
25 |
27.9 |
791 |
1252 |
1329 |
1790 |
|
3×35 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
950 |
1595 |
1551 |
2196 |
|
3×50 |
19 |
1.4 |
1.1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.3 |
35.2 |
1213 |
2079 |
2128 |
2994 |
|
3×70 |
19 |
1.4 |
1.2 |
0.5 |
45/2.0 |
2.1 |
2.2 |
35.6 |
40.1 |
1567 |
2894 |
2678 |
4005 |
|
3×95 |
19 |
1.6 |
1.3 |
0.5 |
42/2.5 |
2.3 |
2.4 |
42 |
46.2 |
2449 |
4188 |
3689 |
5428 |
|
3×120 |
37 |
1.6 |
1.3 |
0.5 |
45/2.5 |
2.4 |
2.5 |
45.3 |
49.6 |
2823 |
5014 |
4174 |
6364 |
|
3×150 |
37 |
1.8 |
1.4 |
0.5 |
49/2.5 |
2.5 |
2.7 |
48.9 |
53.2 |
3327 |
6069 |
4795 |
7537 |
|
3×185 |
37 |
2 |
1.5 |
0.5 |
56/2.5 |
2.7 |
2.8 |
54.5 |
58.7 |
4038 |
7371 |
5686 |
9019 |
|
3×240 |
61 |
2.2 |
1.6 |
0.5 |
63/2.5 |
2.9 |
3.1 |
61.4 |
65.2 |
4994 |
9457 |
6862 |
11325 |
|
3×300 |
61 |
2.4 |
1.7 |
0.5 |
70/2.5 |
3.2 |
3.3 |
67.9 |
71.7 |
6022 |
11564 |
8101 |
13643 |
|
3×400 |
61 |
2.6 |
1.9 |
0.5 |
62/3.15 |
3.4 |
3.6 |
75.4 |
80.5 |
7350 |
14543 |
10535 |
17728 |
|
Four Cores |
|||||||||||||
|
4×10 |
7 |
1 |
1 |
0.2 |
39/1.25 |
1.8 |
1.8 |
20.9 |
23 |
552 |
798 |
1073 |
1319 |
|
4×16 |
7 |
1 |
1 |
0.2 |
35/1.6 |
1.8 |
1.8 |
23.3 |
26.1 |
723 |
1110 |
1213 |
1601 |
|
4×25 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
959 |
1573 |
1559 |
2173 |
|
4×35 |
7 |
1.2 |
1 |
0.2 |
37/2.0 |
1.9 |
2 |
29.7 |
33.6 |
1140 |
2000 |
2006 |
2866 |
|
4×50 |
19 |
1.4 |
1.2 |
0.2 |
44/2.0 |
2.1 |
2.2 |
34.6 |
38.4 |
1524 |
2679 |
2541 |
3696 |
|
4×70 |
19 |
1.4 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.3 |
40.5 |
43.7 |
2338 |
4107 |
3187 |
4956 |
|
4×95 |
19 |
1.6 |
1.2 |
0.5 |
46/2.5 |
2.4 |
2.6 |
45.9 |
50.2 |
2955 |
5274 |
4325 |
6644 |
|
4×120 |
37 |
1.6 |
1.4 |
0.5 |
51/2.5 |
2.6 |
2.7 |
50 |
54.2 |
3466 |
6387 |
4568 |
7888 |
|
4×150 |
37 |
1.8 |
1.4 |
0.5 |
55/2.5 |
2.7 |
2.8 |
53.8 |
58.1 |
4144 |
7800 |
5772 |
9428 |
|
4×185 |
37 |
2 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3 |
60.2 |
64.5 |
4987 |
9430 |
6822 |
11266 |
|
4×240 |
61 |
2.2 |
1.6 |
0.5 |
70/2.5 |
3.1 |
3.3 |
67.7 |
71.5 |
6161 |
12111 |
8233 |
14184 |
|
4×300 |
61 |
2.4 |
1.6 |
0.5 |
61/3.15 |
3.4 |
3.5 |
74.7 |
78.8 |
7346 |
14735 |
10305 |
17694 |
We are China Copper Core PVC Insulated and Sheathed VV Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Copper Core VV Cable Products
Popular jpcable99 Products
High Quality Good Price Copper Flat Wire
ACSR "Hare" Conductor Bare Cable
120mm2 Rubber Sheathed Best Sales Welding Cable
Hot Seller Quadruplex Service Drop Wire
Medium Voltage XLPE Insulated Swa Armoured Power Cable
Popular VV Cable Products
0.6/1kv Copper Low Voltage Wire VV Power Cable
Popular VV Power Cable Products
High Quality Low Voltage Power Cable Outdoor Lighting Wire
PVC Insulated Sheath Electrical Cables
Electrical Cables VV Cable Wire Strap in Cable Wire
VV Copper Core PVC Insulated PVC Sheathed Power Cable
0.6/1kv Electrical Cable VV Cable Power Cable
0.6/1kv Copper Low Voltage Wire VV Power Cable
Tags: Copper Core VV Cable, jpcable99, VV Cable, VV Power Cable