Quick Details

Disconnect Switch 33 Kv, 17.5 Ka, 800 – 1250 a Wit, 17.5 Ka, 800 – 1250 a Without Grounding Blade Double Break

GW4-33 GW4D

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

Product Details

Center Break Isolator and double Break Isolator

These disconnectors are , no load switching devices
which physically isolate the lines. They are designed for
horizontal outdoor application and can also be designed
for vertical installation. For earthing and closing of
switchyard portions of the installation, the earthing

7 Material pin bolt   The pin must be made of hot galvanized stainless steel ASTM A 
153) with its key 
8 Finished   They should present a uniform smooth surface in 
All material, hole and bolt pin, free of burr and defects. Hot dip galvanized according to ASTM A153 standard 
9 Standard applied   ASTM C135, ASTM A 153, ASTM A 536
10 Quality certificate   ISO-9001 or recent
11 Certificate of homologation   Attach certificate of 
DN-DS acceptance 
switches are provided on disconnector. If required.

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

We are China Disconnect Switch 33 Kv, 17.5 Ka, 800 - 1250 a Wit, 17.5 Ka, 800 - 1250 a Without Grounding Blade Double Break manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

High-Voltage Disconnector Switch 36kv

High-Voltage Disconnector Switch 24kv

Disconnecor Switch 33kv

Stay Rodassemblm16conventiona

36kv 400A Load Isolators

Load Break Switch 11kv Rh-B

Popular jgtrade1 Products

U-Bolts

Outdoor Single Pole Fused Recloser by-Pass Switches 24kv

220kv Polymer Sation Post Insulators

Nxj-Dr-1500 Aerial Insulation Wedge Tension Clamp

Shackles

Load Break Switch 15kv

Popular Rotary Switch Products

Single Pole Switch Isolator

Lug, 2 Hole - 350mcm

High and Low Voltage Electroscope

24kv 3 Phase Outdoor Switch Disconnector

Electroscope (with aluminum box and sail bag)

Electroscope

Popular Switch Disconnector Products

Lug, 2 Hole - 350mcm

Three Phase Pre -Payment Split Energy Meter-RF Communication

Suspension Clamp100mm2

1lkv 33kv off-Load Isolator

High -Voltage Isolator /Earth Switch 12kv 400A

High -Voltage Isolate Switch 20kv

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION