Disconnect Switch 33 Kv, 17.5 Ka, 800 - 1250 a Wit, 17.5 Ka, 800 - 1250 a Without Grounding Blade Double Break

China 
                        Disconnect Switch 33 Kv, 17.5 Ka, 800 - 1250 a Wit, 17.5 Ka, 800 - 1250 a Without Grounding Blade Double Break
                      manufacture and supplier

Disconnect Switch 33 Kv, 17.5 Ka, 800 - 1250 a Wit, 17.5 Ka, 800 - 1250 a Without Grounding Blade Double Break image

Get Latest Price Request a quote

Quick Details

Disconnect Switch 33 Kv, 17.5 Ka, 800 – 1250 a Wit, 17.5 Ka, 800 – 1250 a Without Grounding Blade Double Break

GW4-33 GW4D

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

Product Details

Center Break Isolator and double Break Isolator

These disconnectors are , no load switching devices
which physically isolate the lines. They are designed for
horizontal outdoor application and can also be designed
for vertical installation. For earthing and closing of
switchyard portions of the installation, the earthing

7 Material pin bolt   The pin must be made of hot galvanized stainless steel ASTM A 
153) with its key 
8 Finished   They should present a uniform smooth surface in 
All material, hole and bolt pin, free of burr and defects. Hot dip galvanized according to ASTM A153 standard 
9 Standard applied   ASTM C135, ASTM A 153, ASTM A 536
10 Quality certificate   ISO-9001 or recent
11 Certificate of homologation   Attach certificate of 
DN-DS acceptance 
switches are provided on disconnector. If required.

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

We are China Disconnect Switch 33 Kv, 17.5 Ka, 800 - 1250 a Wit, 17.5 Ka, 800 - 1250 a Without Grounding Blade Double Break manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch

Strain Clamps Bolt Type

34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer

Insulator 11kv Pin

ANSI Strain Insulators for Lines

High-Voltage Fuse for The Protection of Power Capacitor

Popular jgtrade1 Products

Polymer Fuse Cutout, Drop out Fuses 27kv 100A

Cutouts Fuses 36kv

T-Connectors for Tubular Bus-Bar Type Mgt

Shackles

Toughened Glass Disc Suspension Electrical Insulator

China Manufacturer Jb-Tl Two Bolts Copper- Aluminium Parallel Groove Clamp 50-240mm2

Popular Rotary Switch Products

Pre-Insulated Bimetal Sleave

High-Voltage Fuse for The Protection of Power Capacitor

IEC Product High Voltage Disconnect Switch Disconnector

PVC Grounding Wire Barrel

Seccionador Disconnector

Gang Insulator 36kv

Popular Switch Disconnector Products

12kv~36kv Load Isolators

Seccionador Disconnector

Fuse Link, - 25 AMP - K

High -Voltage Isolate Switch 24kv 400A

Surge Arrestor 11kv

Outdoor Single Pole Fused Recloser by-Pass Switches 11kv 900A

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.