Pre-Insulated Bimetal Sleave

China 
                        Pre-Insulated Bimetal Sleave
                      manufacture and supplier

Pre-Insulated Bimetal Sleave image

Get Latest Price Request a quote

Quick Details

Pre-Insulated Bimetal Sleave

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

OEI Power

Wooden Case

IEC IEEE

China Nanyang

8535309000

Product Details

Center Break Isolator and double Break Isolator

 

These disconnectors are , no load switching devices
which physically isolate the lines. They are designed for
horizontal outdoor application and can also be designed
for vertical installation. For earthing and closing of
switchyard portions of the installation, the earthing
switches are provided on disconnector. If required.

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Switch
Switch Box
Time Switch
Air Switch
Voltage Switch
Level Switch
View More 

We are China Pre-Insulated Bimetal Sleave manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

Gw9-12kv Outdoor Disconnect Switch Isolating Break Switch

High and Low Voltage Electroscope

High -Voltage Isolate Switch 12kv 600A

Iacm Switch Disconnector 100A - 36kv with Socket and Command

Gw4 Outdoor High Voltage 33kv 35kv 400A 630A 1000A 1250A Three Phase Isolator

Disconnect Switch 145 Kv, 40 Ka, 3150 a with Grounding Blades

Popular jgtrade1 Products

High -Voltage Isolate Switch 40.5kv

Fjz Square Frame Spacers Dampers

Jla-3 Special Grounding Wire for Power Plant

100% Polyester

Fuse Cutout, Drop out Fuses 24kv 200A 10ka

High Voltage Henging Cable Cleat

Popular Rotary Switch Products

Low Voltage Test Pen

Factory Price High Voltage AC 12kv Outdoor Disconnect Switch

34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer

33kv Air Break Switch

Substation Disconnector Double Break Switch

36kv 400A Load Isolators

Popular Switch Disconnector Products

Cutouts Fuses 34.5kv

12kv 400A Load Isolators

Suspension Clamp

34.5/0.433kv, 500kVA Ground Mounted Distribution Transformer

75kv Isolator Switch Images Vertical Break Disconnector and Isolator

Preformed Guy Grip 7/8 Swg Dead Ends

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION