Electrical Distribution System Moa/ 10ka Gapless Surge Arrester up to 500kv
Electrical Distribution System Moa/ 10ka Gapless Surge Arrester up to 500kv image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Y10W5-66/176 |
| Rated voltage———kV | 66 |
| MCOV —————-kV | 52.8 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 221 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
| 1mA D.C reference voltage (kV) | 96 |
| Line discharge level | 1 |
| 2mS long duration impulse current A | 400 |
| 4/10µS High current impulse kA | 100 |
| Lightning impulse withstand kV | 325 |
| Power frequency voltage withstand(dry/wet)kV | 140 |
| 0.1S TOV————–kV | 79.2 |
| 1S TOV—————-kV | 75.9 |
| 10S TOV—————kV | 72.6 |
| 1200S TOV————-kV | 66 |
| Creepage distance —-mm | 2500 |
| Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Electrical Distribution System Moa/ 10ka Gapless Surge Arrester up to 500kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Power Operating Mechanism for Disconnector
Electrical Switch Isolator Isolation Switch (gw1)
High Voltage Equipments 220kv Polymer Lightning Arrester
245kv Centre Break Disconnector (GW4-245/2500)
Low Voltage Price Drop out Fuse Fusible Cutout for Transformer
Electronics Component High Voltage Resistors Used for Surge Arrestors
Popular Lightning Arrester Products
Yh5w-66, 66kv 10ka Surge Arrester
108kv Metal Oxide Lightning Arrester for Overvoltage Protection
220kv Silicon Type Surge Arrester CMA10CX-90/260
Power Station Type Rated Voltage 108kv Porcelain Housed Lighting Arrester
Suspension Clamps (Trunnion Type)
Popular Surge Arrester Products
6kv Silicon Type Surge Arrester Cmr5CD-7.6/27
11kv-36kv Polymer Housed Metal Oxide Lightning Arrester / Surge Arrester
24-27kv Lightning Arrester with Rain Gap
30kv 5ka Surge Arrester Ceramic Housing Lightning Arrester in Fuyang
High Quality 18kv Composite Coat Polymeric Lightning Arrester
Popular Surge Arresters Products
(3-36KV) Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
Rated Current 5ka Polymeric Housed Station Class Surge Diverters with Counter
Polymeric Housed Zinc Oxide Lightning Surge Arresters Series Surge Protector
Innvoation Electrical Station Class Porcelain Surge Arrestors
Kema Tested High Voltage ZnO Surge Arresters with Factory Price
60kv Metal-Oxide Polymer Class3 Station Type Lightning Surge Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters