Electrical Distribution System Moa/ 10ka Gapless Surge Arrester up to 500kv
Electrical Distribution System Moa/ 10ka Gapless Surge Arrester up to 500kv image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | Y10W5-66/176 |
Rated voltage———kV | 66 |
MCOV —————-kV | 52.8 |
Nominal Current——-kA | 10 |
Residual voltage of steep impulse—-at 5kA(kV) | 221 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
1mA D.C reference voltage (kV) | 96 |
Line discharge level | 1 |
2mS long duration impulse current A | 400 |
4/10µS High current impulse kA | 100 |
Lightning impulse withstand kV | 325 |
Power frequency voltage withstand(dry/wet)kV | 140 |
0.1S TOV————–kV | 79.2 |
1S TOV—————-kV | 75.9 |
10S TOV—————kV | 72.6 |
1200S TOV————-kV | 66 |
Creepage distance —-mm | 2500 |
Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Electrical Distribution System Moa/ 10ka Gapless Surge Arrester up to 500kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Export 33kv Lightning Arrester Zinc Oxide Varistor
High Quality Lightning Sound Arrester
High Voltage Equipment Metal Silicone Polymer Arrester with Ceramic Insulator
110kv Ploymer Housed Surge Arrestor with Leave Device
Kema Lighting Arrest Surge Lightning Arrester for Substation
Pd1 33-36kv Porcelain Fuse Cutout Drop-out Fuse Cutout
Popular Lightning Arrester Products
Hangzhou OEM Lightning Protection Systems 30-220kv ZnO Surge Arrestor
0.22kv to 220kv Polymer Housed Metal Oxide Surge Arrester (Series YH)
220kv Polymeric Lightning Surge Arrester
Popular Surge Arrester Products
Polymer Fuse Cutout, Drop out Fuses 2kv 200A
48kv Silicone Polymer Housing Composite Metal Oxide Surge Arrester
Polymer Housed Metal Oxide Surge Arrester Without Gaps
0.25kv~765kv Silicon Rubber (Ceramic) Housed Metal Oxide Gapless Surge Arrester
Power Transmission Type 110kv 10ka ZnO Surge Protector Moa Surge Diverters
High Voltage Surge Arrestors Silicon Metal-Oxide Lightning Arrester Price
Popular Surge Arresters Products
Metal Oxide Polymeric Lightning Arresters
21kv 10ka Polymer Housed Surge Arrester
200kv Metal Oxide Surge Diverters for Electric Station
10ka/ 5ka Gapless Lighting Arrest 21kv Moa Surge Diverter
220kv Substation All Types of Zinc-Oxide Lighting Arrester up to 500kv
Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters