Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Harrier
Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Harrier image
Get Latest Price Request a quote
Quick Details
Product Details
Applications
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
Standard
ANSI/ICEA S-76-474, NF C 33-209, AS3560-1-2000, IEC 60228, and ect.
Specification
Duplex service drop | |||||||||
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | |||||
Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | ||
Bare | OD | ||||||||
AAC | |||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | – | 56.5 | 233.6 | 158 |
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
AAAC | |||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
ACSR | |||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 |
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
DESCRIPTION | INSULATED PHASE CONDUCTORS | Average Insulation Thickness | ||||
Type | Nominal cross-section area | Wire Number in the conductor | Max. resistance at 20 o C | Average diameter of conductors | Rated Strength | |
mm 2 | Number | Ohm/km | Mini mm Max. mm | Mini KN | mm | |
PHASE, NEUTRAL, and PUBLIC LIGHTING |
16 | 7 | 1.910 | 4.6 5.1 | 1.9 | 1.2 |
25 | 7 | 1.200 | 5.8 6.3 | 3.0 | 1.4 | |
35 | 7 | 0.868 | 6.8 7.3 | – | 1.6 | |
50 | 7 | 0.641 | 7.9 8.4 | – | 1.6 | |
70 | 12 | 0.443 | 9.7 10.2 | – | 1.8 | |
95 | 19 | 0.320 | 11.0 12.0 | – | 1.8 | |
120 | 19 | 0.253 | 12.0 13.1 | – | 1.8 | |
150 | 19 | 0.206 | 13.9 15.0 | – | 1.7 | |
PORTER | 54.6 | 7 | 0.630 | 9.2 9.6 | 16.6 | 1.6 |
70 | 7 | 0.500 | 10.0 10.2 | 20.5 | 1.5 | |
95 | 19 | 0.343 | 12.2 12.9 | 27.5 | 1.6 |
We are China Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Harrier manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable 6 AWG Vizsla Products
Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Vizsla
Popular Duplex 4 AWG Harrier Cable Products
Popular Factory Price Duplex Service Drop Products
Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Whippet
Factory Price Duplex Service Drop Cable ABC Cable 4AWG Cairn
Factory Price Duplex Service Drop Cable ABC Cable 4AWG Spaniel
Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Setter
Factory Price Duplex Service Drop Cable ABC Cable 1AWG Airedale
Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Chihuahua
Popular huatongcable Products
Factory Price Duplex Service Drop Cable ABC Cable 6AWG Pekingese
11kv 15kv 33kv Cable 400mm 185mm2 240mm2 50mm2 Cable
Electronic Galvanized Rion Wire 7/10 Swg Stay Wire
Aerial Bundled ABC Cable XLPE Insulated 4*50mm2 - AS/NZS 3560.1
XLPE Power Cable 70mm 95mm 120mm 150mm 185mm 240mm 300mm
Cheap Copper Stranded Wire PVC Coated Electric Copper Wire
Tags: Cable 6 AWG Vizsla, Duplex 4 AWG Harrier Cable, Factory Price Duplex Service Drop, huatongcable