Factory Price Duplex Service Drop Cable ABC Cable 4AWG Cairn
Factory Price Duplex Service Drop Cable ABC Cable 4AWG Cairn image
Get Latest Price Request a quote
Quick Details
Product Details
Applications
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
Standard
ANSI/ICEA S-76-474, NF C 33-209, AS3560-1-2000, IEC 60228, and ect.
Specification
| Duplex service drop | |||||||||
| Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | |||||
| Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | ||
| Bare | OD | ||||||||
| AAC | |||||||||
| Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
| Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
| Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
| Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
| Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
| Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
| Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
| Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | – | 56.5 | 233.6 | 158 |
| Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| AAAC | |||||||||
| Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
| VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
| Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
| Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
| Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
| Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| ACSR | |||||||||
| Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
| Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
| Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
| Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
| Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
| Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
| Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
| Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 |
| Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
| Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
| DESCRIPTION | INSULATED PHASE CONDUCTORS | Average Insulation Thickness | ||||
| Type | Nominal cross-section area | Wire Number in the conductor | Max. resistance at 20 o C | Average diameter of conductors | Rated Strength | |
| mm 2 | Number | Ohm/km | Mini mm Max. mm | Mini KN | mm | |
| PHASE, NEUTRAL, and PUBLIC LIGHTING |
16 | 7 | 1.910 | 4.6 5.1 | 1.9 | 1.2 |
| 25 | 7 | 1.200 | 5.8 6.3 | 3.0 | 1.4 | |
| 35 | 7 | 0.868 | 6.8 7.3 | – | 1.6 | |
| 50 | 7 | 0.641 | 7.9 8.4 | – | 1.6 | |
| 70 | 12 | 0.443 | 9.7 10.2 | – | 1.8 | |
| 95 | 19 | 0.320 | 11.0 12.0 | – | 1.8 | |
| 120 | 19 | 0.253 | 12.0 13.1 | – | 1.8 | |
| 150 | 19 | 0.206 | 13.9 15.0 | – | 1.7 | |
| PORTER | 54.6 | 7 | 0.630 | 9.2 9.6 | 16.6 | 1.6 |
| 70 | 7 | 0.500 | 10.0 10.2 | 20.5 | 1.5 | |
| 95 | 19 | 0.343 | 12.2 12.9 | 27.5 | 1.6 | |
We are China Factory Price Duplex Service Drop Cable ABC Cable 4AWG Cairn manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable 4AWG Cairn Products
Popular Duplex 4AWG Cairn Cable Products
Popular Factory Price Duplex Service Drop Products
Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Retriever
Factory Price Duplex Service Drop Cable ABC Cable 1/0 AWG Basset
Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Setter
Factory Price Duplex Service Drop Cable ABC Cable 2 AWG Chow
Factory Price Duplex Service Drop Cable ABC Cable 4AWG Spaniel
Factory Price Duplex Service Drop Cable ABC Cable 2AWG Doberman
Popular huatongcable Products
ASTM A475 Ehs Grade Zinc Coated Steel Wire Gsw Stay Wire 5/16" 3/16" 5/8" Inch
High Quality Galvanized Steel Wire with ASTM A475
Aerial Bundled Cable XLPE Insulated 4*25mm2 - AS/NZS 3560.1
Bare Conductor Cable ACSR ASTM Standard Al/St ACSR Conductor
Overhead Triplex Service Drop Cyclops Aerial Bundled Cable for Transmission Line
Aerial Bundled ABC Cable XLPE Insulated 4*95mm2 - AS/NZS 3560.1
Tags: Cable 4AWG Cairn, Duplex 4AWG Cairn Cable, Factory Price Duplex Service Drop, huatongcable