Flexible Copper Conductor H05V-V H05V-R H05V-K Building Electrical Wire with PVC Sheathed

China 
                        Flexible Copper Conductor H05V-V H05V-R H05V-K Building Electrical Wire with PVC Sheathed
                      manufacture and supplier

Flexible Copper Conductor H05V-V H05V-R H05V-K Building Electrical Wire with PVC Sheathed image

Get Latest Price Request a quote

Quick Details

Flexible Copper Conductor H05V-V H05V-R H05V-K Building Electrical Wire with PVC Sheathed

Electric Wire

Rmjt

ISO9001, CE, CCC

Home or Building

Round Wire

PVC

PVC

Copper

Building or Constrction

Solid or Stranded

Insulated

300/500V,450/750V

IEC, JIS, BS, Asin, DIN and So on

Required

RMJT

Rolls or According to Cusotmers′ Reques

1.5-240mm2

China

8544492100

Product Details

Electric wire: Copper or aluminum conductor, pvc insulated wire
Electric wire: THW wire, the cable, H07V-U, H05V-U,H07V-R
The conductor type of electric wire: Solid core and stranded core
Cores of electric wire: single core, two cores, three cores

Section area of electric wire
300/500v:0.5mm2,0.75mm2m1.0mm2 
450/750v 1.5mm2,2.5mm2,4mm2,6mm2,10mm2,16mm2,25mm2,35mm2,50mm2,70mm2,95mm2,
120mm2,150mm2,185mm2,240mm2,300mm2m400mm2
300/500v; 2×0.75, 2×1.0, 2×1.5, 2×2.5, 2×4, 5×6, 2×10, 3×0.75, 3×1, 3×1.5, 3×2.5, 3×4, 3×6, 3x10mm2

 

Application
PVC Wire is used for lighting, electronic equipment, instument and communication equipment with rated voltage 450/750V or less

Specification
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.

Type & Name:
 BV         copper core PVC insulated power wire
 BVR      copper core PVC insulated flexible  power wire
 BLV       aluminum core PVC insulated power wire
 BVVB    copper core PVC insulated PVC sheathed parallel power wire
 BLVVB   aluminum core PVC insulated , PVC sheathed wire
 RVS        copper core PVC insulated twisted fexible wire
 RVVB     copper core PVC insulated sheath flat flexible wire

Technical Parameters:

AWG/MCM mm2 Conductor Insulation Shealth Total Weight
    Single Wire OD. PVC Nylon  
    No. Dia.   thick min min OD. Thick mils mm OD.  
      mm mm mil mm mm mil mm mm mil mm mm kg/km
16 1.31 1 1.29 1.29 15 0.38 0.51 14 0.36 2.05 4 0.1 2.25 16.73
14 2.08 1 1.626 1.626 15 0.38 0.51 14 0.36 2.386 4 0.1 2.586 24.53
12 3.29 1 2.048 2.048 15 0.38 0.51 14 0.36 2.808 4 0.1 3.008 36.61
10 5.26 1 2.589 2.589 20 0.51 0.64 19 0.48 3.609 4 0.1 3.809 58
16 1.67 7 0.551 1.653 15 0.38 0.51 14 0.36 2.413 4 0.1 2.613 21.5
14 2.08 7 0.615 1.845 15 0.38 0.51 14 0.36 2.605 4 0.1 2.805 25.84
12 3.30 7 0.775 2.325 15 0.38 0.51 14 0.36 3.085 4 0.1 3.285 38.51
10 5.26 7 0.978 2.934 20 0.51 0.64 19 0.48 3.954 4 0.1 4.154 60.82
9 6.63 7 1.098 3.294 20 0.51 0.64 19 0.48 4.314 5 0.13 4.574 75.34
8 8.32 7 1.23 3.69 30 0.76 0.9 28 0.71 5.21 5 0.13 5.47 98.69
7 10.47 7 1.38 4.14 30 0.76 0.9 28 0.71 5.66 5 0.13 5.92 120.76
6 13.21 7 1.55 4.65 30 0.76 0.9 28 0.71 6.17 5 0.13 6.43 148.58
5 16.65 7 1.74 5.22 30 0.76 0.9 28 0.71 6.74 6 0.15 7.04 183.78
4 21.12 7 1.96 5.88 40 1.02 1.1 35 0.89 7.92 6 0.15 8.22 235.76
2 33.54 7 2.47 7.41 40 1.02 1.1 35 0.89 9.45 6 0.15 9.75 359.83
16 1.23 19 0.287 1.435 15 0.38 0.51 14 0.36 2.195 4 0.1 2.395 16.72
14 2.04 19 0.37 1.85 15 0.38 0.51 14 0.36 2.61 4 0.1 2.81 25.35
12 3.30 19 0.47 2.35 15 0.38 0.51 14 0.36 3.11 4 0.1 3.31 38.27
10 5.19 19 0.59 2.95 20 0.51 0.64 19 0.48 3.97 4 0.1 4.17 59.86
9 6.50 19 0.66 3.3 20 0.51 0.64 19 0.48 4.32 5 0.13 4.58 73.64
8 8.17 19 0.74 3.7 30 0.76 0.9 28 0.71 5.22 5 0.13 5.48 95.16
7 10.53 19 0.84 4.2 30 0.76 0.9 28 0.71 5.72 5 0.13 5.98 120.74
6 13.19 19 0.94 4.7 30 0.76 0.9 28 0.71 6.22 5 0.13 6.48 145.02
5 16.45 19 1.05 5.25 30 0.76 0.9 28 0.71 6.77 6 0.15 7.07 180.78
4 21.13 19 1.19 5.74 40 1.02 1.1 35 0.89 7.78 6 0.15 8.08 229.38
3 26.40 19 1.33 6.45 40 1.02 1.1 35 0.89 8.49 6 0.15 8.79 280.88
2 33.58 19 1.5 7.26 40 1.02 1.1 35 0.89 9.3 6 0.15 9.6 350.23
1 42.12 19 1.68 8.15 50 1.27 1.38 45 1.14 10.69 7 0.18 11.05 447.22
1/0 53.30 19 1.89 9.14 50 1.27 1.38 45 1.14 11.68 7 0.18 12.04 555.15
2/0 67.07 19 2.12 10.3 50 1.27 1.38 45 1.14 12.84 7 0.18 13.2 687.52
3/0 84.53 19 2.38 11.6 50 1.27 1.38 45 1.14 14.14 7 0.18 14.5 854.27
4/0 107.18 19 2.68 13 50 1.27 1.38 45 1.14 15.54 7 0.18 15.9 1068.65
250 125.72 37 2.08 14.2 60 1.52 1.67 55 1.4 17.24 8 0.2 17.64 1272.29
300 151.06 37 2.28 15.5 60 1.52 1.67 55 1.4 18.54 8 0.2 18.94 1512.81
350 177.29 37 2.47 16.8 60 1.52 1.67 55 1.4 19.84 8 0.2 20.24 1761.4
400 202.53 37 2.64 17.9 60 1.52 1.67 55 1.4 20.94 8 0.2 21.34 1999.42
500 252.89 37 2.95 19.7 60 1.52 1.67 55 1.4 22.74 8 0.2 23.14 2470.99
600 304.24 61 2.52 22 70 1.78 1.94 65 1.65 25.56 9 0.23 26.02 2998.91
650 328.87 61 2.62 22.9 70 1.78 1.94 65 1.65 26.46 9 0.23 26.92 3231.59
750 378.30 61 2.81 24.6 70 1.78 1.94 65 1.65 28.16 9 0.23 28.62 3697.59
1000 506.04 61 3.25 28.4 70 1.78 1.94 65 1.65 31.96 9 0.23 32.42 4896.32

3.Specification:
H05V-U Specification

300/500V,Copper Conductor PVC Insulated Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 0.5 1 0.8 0.6 2.00 8.16
1 X 0.75 1 0.97 0.6 2.17 10.71
1 X 1.0 1 1.13 0.6 2.33 13.48
300/500V, Copper Conductor Heat Resistant PVC Insulated Connecting Wire at 90ºC
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 0.5 1 0.8 0.6 2.00 8.16
1 X 0.75 1 0.97 0.6 2.17 10.71
1 X 1.0 1 1.13 0.6 2.33 13.48
1 X 1.5 1 1.38 0.7 2.78 19.70
1 X 2.5 1 1.78 0.8 3.38 31.20

H05V-R  Specification

300/500V,Copper Conductor PVC Insulated Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. mm mm mm kg/km
1 X 0.75 7 0.37 0.6 2.31 11.3
1 X 1.0 7 0.43 0.6 2.49 14.2

H05V-K Specification  

300/500V,Copper Conductor PVC Insulated Flexible Connecting Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 0.5 28 0.15 0.6 2.16 8.65
1 X 0.75 40 0.15 0.6 2.40 11.22
1 X 1.0 32 0.20 0.6 2.54 14.32
300/500V, Copper Conductor Heat Resistant PVC Insulated Connecting Wire at 90ºC
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 0.5 28 0.15 0.6 2.16 8.65
1 X 0.75 40 0.15 0.6 2.40 11.22
1 X 1.0 32 0.20 0.6 2.54 14.32
1 X 1.5 30 0.25 0.7 3.00 20.58
1 X 2.5 49 0.25 0.8 3.70 32.24

H07V-R Specification

450/750V,Copper Conductor PVC Insulated Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 1.5 7 0.52 0.7 2.96 20.4
1 X2.5 7 0.67 0.8 3.61 32.3
1 X4.0 7 0.85 0.8 4.15 47.8
1 X6.0 7 1.04 0.8 4.72 67.7
1 X10 7 1.35 1.0 6.05 113.1
1 X 16 7 1.70 1.0 7.1 170.9
1 X 25 7 2.14 1.2 8.82 268.5
1 X 35 7 2.52 1.2 9.96 362.8
1 X 50 19 1.78 1.4 11.7 492.2
1 X 70 19 2.14 1.4 13.5 694.2
1 X 95 19 2.52 1.6 15.8 959.2
1 X 120 37 2.03 1.6 17.41 1197.1
1 X 150 37 2.25 1.8 19.35 1472.9
1 X 185 37 2.52 2.0 21.64 1846.1
1 X 240 61 2.25 2.2 24.65 2416.5
1 X 300 61 2.52 2.4 27.48 3023.6
1 X 400 61 2.85 2.6 30.85 3851.7

 
H07V-K Specification

450/750V,Copper Conductor PVC Insulated Flexible Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 1.5 30 0.25 0.7 3.00 20.6
1 X2.5 49 025 0.8 3.70 32.2
1 X4.0 56 0.30 0.8 4.21 48.
1 X6.0 84 0.30 0.8 5.57 71.2
1 X10 84 0.40 1.0 7.30 124.4
1 X 16 126 0.40 1.0 8.00 175.8
1 X 25 196 0.40 1.2 10.10 272.5
1 X 35 276 0.40 1.2 11.87 373.9
1 X 50 396 0.40 1.4 13.93 532.8
1 X 70 360 0.50 1.4 16.12 737.9
1 X 95 475 0.50 1.6 19.24 978.1
1 X 120 608 0.50 1.6 19.95 1222.5
1 X 150 756 0.50 1.8 23.34 1529.7
1 X 185 925 0.50 2.0 25.54 1870.1
1 X 240 1221 0.50 2.2 27.85 2443.4
1 X 300 1525 0.50 2.4 32.49 3032.9
1 X 400 2013 0.50 2.6 35.35 3958.6

HO3VV-F and AO3VV-F Specification

Rated Voltage Copper Conductor PVC Insulated PVC Sheathed Round Flexible Connecting Wire
Nominal Cross Section Conductor Construction Insulation Thickness PP Tape Sheath Thickness Overall Diameter Approx. Net Weight
mm2 No./mm mm No./mm mm mm kg/km
300/300V 2 X0.5 16/0.20 0.5 1/0.05 0.6 5.87 34.80
2 X 0.75 24/0.20 0.5 1/0.05 0.6 6.50 43.40
3 X 0.5 16/0.20 0.5 1/0.05 0.6 6.22 44.01
3 X 0.75 24/0.20 0.5 1/0.05 0.6 6.90 55.64
300/500V 2 X 0.5 16/0.20 0.6 1/0.05 0.7 5.78 36.69
2 X 0.75 24/0.20 0.6 1/0.05 0.8 6.78 47.02
2 X 1.0 32/0.20 0.6 1/0.05 0.8 6.78 54.79
2 X 1.5 30/0.25 0.7 1/0.05 0.8 7.71 72.31
2 X 2.5 49/0.25 0.8 1/0.05 0.8 9.51 111.90
3 X 0.5 16/0.20 0.6 1/0.05 0.7 6.11 46.72
3 X 0.75 24/0.20 0.6 1/0.05 0.8 6.74 59.71
3 X 1.0 32/0.20 0.6 1/0.05 0.8 7.17 71.03
3 X 1.5 30/0.25 0.7 1/0.05 0.8 8.17 95.26
3 X 2.5 49/0.25 0.8 1/0.05 1.2 10.48 156.81
3 X 4.0 50/0.30 0.8 1/0.05 1.2 11.38 199.81
4 X 1.0 32 X 0.20          
4 X 1.5 48 X 0.20          
4 X 2.5 77 X 0.20          
4 X 4.0 56 X 0.30          
4 X 6.0 84 X 0.30          
4 X 10 84 X 0.40          
4 X 16 126 X 0.40          
5 X 1.5 48 X 0.20          
5 X 2.5 77 X 0.20          
5 X 4.0 56 X 0.30          
5 X 6.0 84 X 0.30          
5 X 10 84 X 0.40          
5 X 16 126 X 0.40          

H03VVH2-F Specification

300/500V,Copper Conductor PVC Insulated PVC Sheathed Flat Wire
Nominal Cross Section Conductor Construction Insulation Thickness Sheath Thickness Overall Diameter Approx. Net Weight
mm2 No./mm mm mm mm x mm kg/km
2 X 0.75 1/0.97 0.6 0.9 3.97 x 6.14 39.0
2 X 1.0 1/1.13 0.6 0.9 4.13 x6.46 45.6
2 X1.5 1/1.37 0.7 0.9 4.57×7.34 60.5
2 X2.5 1/1.76 0.8 1.0 5.36×8.72 89.9
2 X4 1/2.24 0.8 1.0 5.84×9.68 123.5
2 X4 7/0.85 0.8 1.0 6.15×10.30 130.6
2 X6 1/2.74 0.8 1.1 6.54×10.88 169.4
2 X6 7/1.04 0.8 1.1 6.92×11.64 179.2
2 X10 7/1.35 1.0 1.2 9.45×14.50 286.5
2 X16 7/1.70 1.0 1.2 9.50×16.60 412.3
3 X0.75 1/0.97 0.6 0.9 3.97×8.31 55.2
3 X1.0 1/1.13 0.6 0.9 4.13×8.79 65.0
3 X1.5 1/1.38 0.7 0.9 4.58×10.14 87.7
3 X2.5 1/1.76 0.8 1.0 5.36×12.08 129.9
3 X4 1/2.24 0.8 1.1 6.04×13.72 184.7
3 X 4 7/0.85 0.8 1.1 6.35×14.65 195.4
3 X6 1/2.74 0.8 1.1 6.54×15.22 247.7
3 X 6 7/1.04 0.8 1.1 6.92×16.36 262.0
3 X10 7/1.35 1.0 1.2 8.45×20.55 420.8

 

Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires no/mm Lower Limit mm Upper Limit mm
0.75 24/0.20 0.6 0.8 6.0 7.6 63
1.0 32/0.20 0.6 0.8 6.4 8.0 73
1.25 40/0.20 0.7 0.8 7.0 8.6 84
1.5 30/0.25 0.7 0.8 7.4 9.0 95
2.5 50/0.25 0.8 1.0 8.9 11.0 145

4.Package:
Packing in plastic reel, paper reel ,wooden drum or as customer’s requirement.

5.Our factory:
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. 

Customer Visit
We have a professional sales team with each of them has engaged in this job for 3-10 years,
so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service,till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

 

FAQ:

I didn’t find the cable which I need in this page?
If you didn’t find the species of cables you need, please contact us directly, we will reply you quickly.

Are you a trading company or manufacture?
RMJT is a professional manufacturer in Henan, China.

What is the MOQ?
Mostly we sell from stock for normal items, you can buy any quantity unless its customed-made.

Can you offer me a free sample?
Yes, after price confirmation, you can require for samples to check our quality.sample is free but the freight charge should be paid.

How long get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days

How is your package?
Normally packed with coils and cartons, and wooden/steel wooden drums, other ways can be done according you.

How is the payment?
T/T, L/C is accepted.

What is the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.

We are China Flexible Copper Conductor H05V-V H05V-R H05V-K Building Electrical Wire with PVC Sheathed manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Building Wire Products

H05VV-F 2x6mm2 300/500 V PVC Insulated Multi-core Cables With Flexible Copper Conductor

12/2 Solid Cu Nm-B

UL83 Listed AWG 10 12 14 Thhn Thwn Building Wire

#4AWG XHHW-2 Annealed Copper Conductor XLPE Insulation Cable 600 Volts

Nmd90 14/2AWG 300 Volts Flat Nmd90 Copper Wire Cable

Copper Flat Hebei Huatong Cables Soft Packing, or as Your Request 300V Canada Wire

Popular H05V-V Products

  • No related articles
  • Popular PVC Sheathed Wire Products

    Na2xy Ce Approved Wire XLPE Insulation PVC Sheathed Wire, Power Cable

    Popular renmincable Products

    PVC Sheath Electrical Power Cable with XLPE Insulation

    Factory Price ACSR Conductor with ACSR Moose

    Nylon Jacket Electrical Cable Building Wire Thhn

    15kv Aluminium Wire Three Cores XLPE Power Cable

    ABC Cable Aluminum Conductor Covered Line Wire

    2*2.5mm PVC Insulated Twin Flat Rvs Twisted Electric Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION