Flexible XLPE PVC Insulated Electric Aerial Bundle Overhead Quadruplex Duplex Aluminum ABC Cable
Flexible XLPE PVC Insulated Electric Aerial Bundle Overhead Quadruplex Duplex Aluminum ABC Cable image
Get Latest Price Request a quote
Basic Info.
Packaging & Delivery
Product Description
LUOYANG SANWU CABLE GROUP with registered capital of 100 million RMB, is a high-tech development company for scientific research, industry producing and trading, offering a diverse selection of quality wires and cables to industrial customers in more than 50 countries worldwide. The leading products are ACSR, Overhead ABC cables, Conductor, AAAC, AAC, power cable etc.
In terms of quality, it is highly controlled by our company to ensure that all the products we sell meet your requirements and give you reassurance with excellent after-sale service.In terms of service, we are focusing on your need, we concern what you concern and request what you request to provide a more satisfied service.
Product Description
ASTM BS CSA Standard Overhead Aluminium Conductor Aerial Bundle Cable
ABC Cable Application
This production is suitable for electric cable below 10KV AC, which will be mainly used for city power grid transmission line. It is simple structure,
safety and stable and is of good mechanism physical and electricity function. And also it has good function of proof track, creepage
discharge, and air. Compared with naked wire, it has small gap so that can save wire route and decrease voltage drop. What is the
most important is that it will decrease the accident in power supplying and make people safe.
Specific Property for ABC Cable
1) the min. temperature of laying cable is not lower than 20°C.
2) the Max. temperature of HDPE insulated cable is 150°C, and that of the XLPE insulated cable is 250°C when short circuit (5 seconds ).
3) the Max. long-time working temperature of conductor of the HDPE insulated cable is 75°C,and that of the XLPE insulated cable is 90°C.
4) every fault time of single-phase earth shall be less than one minute. And that also shall be less than 8 hours per time and be less than 125hours every year.
5) the permissible curving radius of single-core cable should be not less than 20(D±d) ±5%mm, and that of the multi-core cable should be not less than 15(D±d) ±5%mm.
ABC cable sketch structure as follows:
Executive Standard:IEC
Phas e | Neutral | Phas e | Neutral |
Approx. Overall Diam eter |
Max. D.C. Res is tance of Conductor at 20ºC |
||||
AAC+UV-XLPE | AAAC | Com pact Conductor | UV-XLPE Ins ulation | Conductor | |||||
No.X Norm al Cr os s Section of Cores |
No.X Norm al Cr os s Section of Cores |
No.of Al.Wire | Overall Dia. | Norm al Thick nes s | Min. | No./Dia. of Al Alloy Wire | Phas e | Neutral | |
No. X m m 2 | No. X m m 2 | – | m m | m m | Min. | No./m m | m m | ohm /k m | ohm /k m |
1 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.3 | 1.91 | 2.217 |
1 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 14.7 | 1.2 | 1.393 |
1 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 17.3 | 0.868 | 1.007 |
1 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.1 | 0.641 | 0.744 |
1 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.1 | 0.443 | 0.514 |
1 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.3 | 0.32 | 0.371 |
1 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 30.2 | 0.253 | 0.294 |
1 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 |
1 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 37.7 | 0.164 | 0.19 |
1 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0.125 | 0.145 |
2 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 |
2 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 16.63 | 1.2 | 1.393 |
2 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 19.51 | 0.868 | 1.007 |
2 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 |
2 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25.7 | 0.443 | 0.514 |
2 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.32 | 0.371 |
2 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 33.41 | 0.253 | 0.294 |
2 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 |
2 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 41.69 | 0.164 | 0.19 |
2 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0.125 | 0.145 |
3 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 |
3 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.2 | 1.393 |
3 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 |
3 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 |
3 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 |
3 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.32 | 0.371 |
3 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 37.87 | 0.253 | 0.294 |
3 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 |
3 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 47.25 | 0.164 | 0.19 |
3 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0.125 | 0.145 |
Phas e | Neutral | Phas e | Neutral |
Approx. Overall Diam eter |
Max. D.C. Res is tance of Conductor at 20ºC |
||||
AAC+UV-XLPE | AAAC | Com pact Conductor | UV-XLPE Ins ulation | Conductor | |||||
No.X Norm al Cr os s Section of Cores |
No.X Norm al Cr os s Section of Cores |
No.of Al.Wire | Overall Dia. | Norm al Thick nes s | Min. | No./Dia. of Al Alloy Wire | Phas e | Neutral | |
No. X m m 2 | No. X m m 2 | – | m m | m m | Min. | No./m m | m m | ohm /k m | ohm /k m |
1 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.3 | 1.91 | 2.217 |
1 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 14.7 | 1.2 | 1.393 |
1 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 17.3 | 0.868 | 1.007 |
1 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.1 | 0.641 | 0.744 |
1 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.1 | 0.443 | 0.514 |
1 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.3 | 0.32 | 0.371 |
1 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 30.2 | 0.253 | 0.294 |
1 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 |
1 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 37.7 | 0.164 | 0.19 |
1 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0.125 | 0.145 |
2 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 |
2 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 16.63 | 1.2 | 1.393 |
2 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 19.51 | 0.868 | 1.007 |
2 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 |
2 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25.7 | 0.443 | 0.514 |
2 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.32 | 0.371 |
2 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 33.41 | 0.253 | 0.294 |
2 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 |
2 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 41.69 | 0.164 | 0.19 |
2 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0.125 | 0.145 |
3 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 |
3 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.2 | 1.393 |
3 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 |
3 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 |
3 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 |
3 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.32 | 0.371 |
3 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 37.87 | 0.253 | 0.294 |
3 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 |
3 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 47.25 | 0.164 | 0.19 |
3 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0.125 | 0.145 |
Phase | Neutral | Service Connection | Phase | Neutral | Service Connection | Approx. Overall Diameter of Bundled Cable |
|||||
AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No. of Al. Wire | Overall Dia. | Normal | No./Dia. of Al. Wire | Normal | No. of Al. Wire | Overall Dia. | Normal | |
Thickness | Thickness | Thickness | |||||||||
No. X mm2 | No. X mm2 | No. X mm2 | – | mm | mm | mm | mm | No./mm | mm | mm | mm |
3 X 16 | 1 X 50 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 1 X 16 | 7/2.24 | 6 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 1 X 16 | 7/2.58 | 7 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 1 X 16 | 7/3.00 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 1 X 16 | 19/2.15 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 1 X 16 | 19/2.58 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 1 X 16 | 18/3.00 | 13 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 44.2 |
3 X 16 | 1 X 50 | 2 X 16 | 7/1.70 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 2 X 16 | 7/2.24 | 6 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 2 X 16 | 7/2.58 | 7 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 2 X 16 | 7/3.00 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 2 X 16 | 19/2.15 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 2 X 16 | 19/2.58 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 2 X 16 | 18/3.00 | 13 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 44.2 |
Executive Standard:ASTM
Code Word | AWG or k cm il | Bare neutral Mes s enger | Phas e conductor | Weight (k g/k m ) | ||
AAAC s trading and w ires dia(m m ) |
Rated Strength (lbs ) |
AAC s trading and w ires dia(m m ) |
ins ulation thick nes s (m m ) | |||
Bay | 3*6AWG+ 1*30.58 | 7/ 1.68 | 1110 | 1/4.11 | 1.14 | 207 |
French Coach | 3*6AWG+ 1*30.58 | 7/ 1.68 | 1110 | 7/ 1.56 | 1.14 | 2 13 |
German Coach | 3*4AWG+ 1*48.69 | 7/2. 12 | 1760 | 1/5.1 9 | 1.14 | 309 |
Arabian | 3*4AWG+ 1*48.69 | 7/2. 12 | 1760 | 7/ 1.96 | 1.14 | 316 |
Belgian | 3*2AWG+ 1*77.47 | 7/2.67 | 2800 | 7/2.47 | 1.14 | 476 |
Shet land | 3*1/0AWG+ 1*123.3 | 7/3.37 | 4460 | 19/ 1.89 | 1.52 | 768 |
Thoroughbred | 3*2/0AWG+ 1*155.4 | 7/3.78 | 5390 | 19/2.13 | 1.52 | 945 |
Trotter | 3*2/0AWG+ 1*195.7 | 7/4.25 | 6790 | 19/2.39 | 1.52 | 1166 |
Walking | 3*4/0AWG+ 1*246.9 | 7/4.77 | 8560 | 19/2.68 | 1.52 | 1442 |
Executive Standard:NFC
Des cr iption |
Nom inal cros s -s ection aera |
Wire num ber in Conductor | Max res is tance at 20 | Average diam eter of conductor |
Rated Strength | Average ins ulation thick nes s | |
m m 2 | No. | Ohm /k m | Min(m m ) | Max(m m ) | KN | m m | |
PHASE, NEUTRAL, |
16 | 7 | 1.91 | 4.6 | 5.1 | 1.9 | 1.2 |
25 | 7 | 1.2 | 5.8 | 6.3 | 1.4 | ||
35 | 7 | 0.868 | 6.8 | 7.3 | 1.6 | ||
50 | 7 | 0.641 | 7.9 | 8.4 | 1.6 | ||
70 | 12 | 0.443 | 9.7 | 10.2 | 1.8 | ||
95 | 19 | 0.32 | 11 | 12 | 1.8 | ||
120 | 19 | 0.253 | 12 | 13.1 | 1.8 | ||
150 | 19 | 0.206 | 13.9 | 15 | 1.7 | ||
PORTER | 54.6 | 7 | 0.63 | 9.2 | 9.6 | 1.6 | |
70 | 7 | 0.5 | 10 | 10.2 | 1.5 | ||
95 | 19 | 0.343 | 12.2 | 12.9 | 27.5 | 1.6 |
Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997 (equivalent to IEC 60889:1987)
2) The zinc coated steel wire used for ACSR confirms to IEC 60888:1987
3) Production can be arranged according to customers’ requirement such as material standard etc.
4) We can also produce products according to the Standard of BS215, ASTM B232, and DIN48204.Technical characteristics
Certifications
ISO9001:2008, OHSAS, CCC, TUV Certifications.
Package&Shipping:
For Package: Support to pack as rolls, or with wooden drum or wooden steel drums.
Shipment terms:
By FOB, CFR or CIF by sea.
By DHL, UPS, Fedex express etc are also available.
Our Services
Luoyang Asian Sun Industrial Group Co., Ltd, a professional wires and cables manufacturer for 6 years in China. Asian Sun attends International Exhibitions every year, we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) and solar pv cables etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 200,081 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC, CQC, ISO9001:2008;
4. Payment terms: T/T, L/C, O/A;
5. Guarantee: 20 years;
6. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.
Customers Visiting:
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Flexible XLPE PVC Insulated Electric Aerial Bundle Overhead Quadruplex Duplex Aluminum ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Conductor Products
Bare Conductor for Overhead Conductor Acar 1300 Mcm ASTM Standard
ACSR, Aluminium Conductors Steel Reinforced (DIN 48204)
ACSR Conductor Swan for Tender
Copper Conductor/Bare Conductor Rod
High Quality Aluminum Conductors Steel Reinforced ACSR Cable
All Aluminum Alloy Conductor for Sell
Popular dycable Products
High Quality AAC Conductor From Experienced Manufacturer
Overhead Conductor ACSR Rabbit Conductor Price
Aluminum Conductor Twisted Aerial Bundle Cable ABC Cable
0.6/1kv PVC XLPE Insulated Aluminum Wire 4X50 mm2 ABC Cable
Hot Selling Black Solar DC Cable DC Power Cable 6mm2
ASTM B399 AAAC Cable All Aluminium Alloy Conductors
Popular Flexible XLPE PVC Insulated Electric Aerial Bundle Overhead Quadruplex Duplex Aluminum ABC Cable Products
Popular Wire Cable Products
0.6/1kv Multicore Power Electric Wire Cable for Power Transmission
3*6AWG Aluminum Alloy Conductor XLPE Insulation Sheath Concentric Cable Overhead
High Quality French Standard ABC Cable Widely Used in Rural Electrification
0.6/1.0kv Aluminum Conductor XLPE PE PVC Insulation Cable Overhead 4*120sqmm ABC Cable
Rmjt Insulated Export Drums or Roll Overhead Electrical Lines Aerial Bundle Cable Size
0.6/1kv Aluminum Conductor XLPE/PE Insulated Duplex Service Drop 1*25+25 (Bare) Overhead ABC Cable
Tags: Conductor, dycable, Flexible XLPE PVC Insulated Electric Aerial Bundle Overhead Quadruplex Duplex Aluminum ABC Cable, Wire Cable