High Voltage 66kv Sofy-Dry Type Outdoor Termination

China 
                High Voltage 66kv Sofy-Dry Type Outdoor Termination
              manufacture and supplier

High Voltage 66kv Sofy-Dry Type Outdoor Termination image

Get Latest Price Request a quote

  • Overview
  • Company Profile
  • FAQ

Overview

Basic Info.

Model NO.
YJZWRG

Material
Silicone Rubber

Color
Grey

Usage
Connect Cable

Standard
IEC60502

Transport Package
Wooden Case

Specification
240-1600mm2

Trademark
9V

Origin
China

HS Code
8535900090

Production Capacity
50000sets/Year

Packaging & Delivery

Package Size
1100.00cm * 1100.00cm * 1100.00cm

Package Gross Weight
200.000kg

Product Description

66-220kV High Voltage Cable Accessories

Our company provides the voltage level of 48/66kV, 64/110kV, 127/220kV and other series of cable accessories are all in accordance with IEC 60502, IEC 60840, IEC 62067, IEC 60859, IEC 62271-209, GB/T 11017, GB/T 18890, GB/T 12706, GB 311, GB 772, DL508, DL509, JB/T8144 and other standards, and have passed the stringent factory test, type test, pre-qualification test.

Soft dry type outdoor termination
Scope of application


For cross linked polyethylene insulated power cables 240-3000mm2.

Suitable for large-scale chemical industry, iron and steel, power substations, coastal areas.

Features

Terminal for the whole prefabricated size of the umbrella skirt structure plus streamline cone shape, has a Good anti-fouling flash, weather resistance, anti-leakage marks, anti-electro-etching and water-repellent ability.

The stress cone is made of imported liquid silicone rubber injection molding, with a long and stable holding force and electric field uniformity.

Compact structure, small size, light weight, easy to install.

Flexible installation position, can be installed vertically and inclined, anti-vibration, good explosion-proof.

Structure & Size

1,the pole

2,equalizing cover

3,core insulation

4,prefabricated body  

5,stress cone  

6,tail pipe

7,cable

Size / mm 38/66kV 50/66kV 64/110kV 76/132kV
L 1140 1140 1460 1620
A 1700 1700 2000 2320

Test Specification
All test classifications and codes:

No.# Test Name Code
1 Routine test R
2 Sample test S
3 Type test T
4 Pre-qualification test P
5 Additional test A

The following routine tests are performed on stress cones, epoxy bushings of GIS terminals and prefabricated intermediate joints of each product at 66kV and above.

Item Voltage
38/66kV 50/66kV 64/110kV 76/132kV 127/220kV
Partial discharge 54kV, no detectable local discharge over background 72kV, no detectable local discharge over background 96kV, no detectable local discharge over background 114kV, no detectable local discharge over background 190kV, no detectable local discharge over background
The power frequency withstand voltage 90kV/30min 125kV/30min 160kV/30min 190kV/30min 318kV/30min
Sealing Seal fittings, porcelain bushings, composite bushings for 0.25±0.01MPa/1h, no leakage
The epoxy casing was subjected to 0.6~0.7MPa/1h with no leakage.
Appearance The products are free of damage, cracks, and other defects that may affect the quality and appearance of the products.

66-220kV Main Test Parameters

Item Standard Test Category Product Category
48/66kV 64/110kV 127/220kV Porcelain Sleeve Terminal Composite Sleeve Terminal GIS terminal Straight / Insulated Joint flexible terminal
Sealing Fittings, Porcelain, Composite Sleeves 0.25±0.01MPa/1h, no leakage R yes yes yes
Epoxy Sleeve 0.6~0.7MPa/1h, no leakage
Partial discharge of prefabricated parts 72kV 96kV 190kV R yes yes yes yes yes
Detects no more than background discharge
Frequency withstand voltage of prefabricated parts  120kV 160kV 318kV R yes yes yes yes yes
30min,no flashover, no breakdown
Partial discharge at room temperature 72kV 96kV 190kV T yes yes yes yes yes
Detects no more than background discharge
Thermal cycling voltage test 96kV 128kV 254kV T yes yes yes yes yes
20 cycles, no flashover, no breakdown
Partial discharge test at high temperature 72kV 96kV 190kV T yes yes yes yes yes
Detects no more than background discharge
Lightning impact test and subsequent frequency withstand voltage test 450kV 550kV 1050kV T yes yes yes yes yes
10 times for each positive and negative polarity
120kV 160kV 318kV
15min, no flashover, no breakdown
Directly buried joint outer protective layer immersion voltage test Two ends impact among the 60/75kV,an end of hit 30/37.5kV Two ends impact among the 60/95kV,an end of hit 30/47.5kV T yes
Sealing test after assembly of accessories 0.25±0.01MPa/1h, no leakage T yes yes yes yes yes
Outdoor terminal rain frequency voltage test 140kV 185kV 460kV T yes yes yes
1min, no flashover, no breakdown
Pillar insulator voltage test 20kV/1min, no flashover, no breakdown T yes yes
Radio interference test for outdoor terminals 61kV 81kV 140kV A yes yes yes
1MHz radio interference, voltage ≤ 450μV 1MHz radio interference, voltage ≤ 500μV
Accessory specimen test Visual inspection of accessory systems containing cables with no signs of deterioration that could affect the normal operation of the system T yes yes yes yes yes
DC voltage test / No breakdown between conductor and metal shield in connector, 20kV/1min. T yes
Performance test of crimped connectors for conductor connecting rods The total area after crimping is not more than 1.2 times the resistance of an equal length of conductor of the same cross-section. T yes yes yes yes yes

 

Company Profile

 

FAQ

 

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China High Voltage 66kv Sofy-Dry Type Outdoor Termination manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular High Voltage 66kv Sofy-Dry Type Outdoor Termination Products

  • No related articles
  • Popular jiuweielectric Products

    Wholesale PVC Customized Electrical Tape

    Flame-Retardant Adhesive Medium Wall Heat Shrink Tubing

    1~35kv Vmph Insulation Protection Box Busbar Cover

    Hot Sale PVC Heat Shrink Electrical Insulation Tape

    Direct Sale Heat Shrink Bus Bar Tubing Various Specs Heat Shrinkable Cable Sleeve

    Corrosion Resistant Cable Protection Sleeve Heat Shrinkable Cable Repair Sleeves

    Popular Outdoor Termination Products

    38/66kv Cable Accessory Composite Bushing Outdoor Termination

    110kv Porcelain Bushing Outdoor Termination

    132kv Composite Bushing Outdoor Termination

    127/220kv Porcelain Bushing Outdoor Termination

    132kv Porcelain Bushing Outdoor Termination

    138kv Soft Dry Type Outdoor Termination Cable Accessory

    Popular Soft Dry Type Products

    38/66kv Soft Dry Type Outdoor Termination

    76/132kv Soft Dry Type Outdoor Termination

    138kv Soft Dry Type Outdoor Termination

    66kv Soft Dry Type Outdoor Termination

    66kv Cable Accessory Soft Dry Type Outdoor Termination

    64/110kv Soft Dry Type Outdoor Termination

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION