High Voltage Double-Column Centre Break Disconnector
High Voltage Double-Column Centre Break Disconnector image
Get Latest Price Request a quote
Quick Details
Product Details
1. Simple Structure, reliable property, wide usage, economical and long-time life.
2. Complete specification and satisfy user’s different parameters requirements.
3. Connecting terminal and the electric pole is made by casting aluminum-alloy and section bar, having the good property of high-intensity, good flowing and anti-corrosion
4. In the galvanic circle, the section is the combination structure made by screw fix linking, having the good property of stable flowing, high reliability, simple change way and convenient adding volume way.
5. In the galvanic circle, the contact and finger is made by T2Y pure copper tap whose connecting part is coated by 30μ M silver.
6. Finger spring is made by the stainless steel and its design is the inside hiding and outside press structure which is convenient for testing and changing.
7. Bearing block is made by high-intensity casting steel (disposed by hot zinc coating), the height can be adjusted and have the function of damping.
8. All the operating rod and linking rod are supplied by manufacturer, which is convenient for loading, adjusting and testing.
9. Can be supplied as a whole above the ground according to user’s requirement.
No | Item | Technical parameter | |||||
1 | Rated Voltage kV | 72.5 | 123 | 145 | 245 | ||
2 | Rated Current A | 1250 1600 2000 2500 3150 4000 | |||||
3 | Rated Short Time withstand current and Time kA/s | 25~50/4 | |||||
4 | Rated Peak withstand current kA | 63~125 | |||||
5 | 1min power frequency withstand voltage (effective value) kV | To earth | 140 | 230 | 275 | 460 | |
To phase | 140 | 230 | 275 | 460 | |||
Across Isolating DS | 180 | 300 | 315 | 605 | |||
6 | Lightning Impulse wishstand voltage (peak value) kV |
To earth | 325 | 550 | 650 | 1050 | |
To phase | 325 | 550 | 650 | 1050 | |||
Across Isolating DS | 405 | 650 | 750 | 1200 | |||
7 | Rated mechanical terminal load N | Level of lateral load | 750 | 1500 | 1500 | 2000 | |
Level of vertical load | 500 | 1000 | 1000 | 1500 | |||
Vertical | 750 | 1000 | 1000 | 1250 | |||
8 | |||||||
9 | Max Man Operative Moment N. m | 200 | |||||
10 | Motor Drive operating mechanism control voltage V | AC220; DC110, 220 | |||||
11 | Motor Drive operating mechanism motor voltage V | AC220, 380; DC110, 220 |
We are China High Voltage Double-Column Centre Break Disconnector manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Disconnect Switch Products
Hgw9-10 Outdoor High-Voltage Porcelain Disconnect Switch
High Voltage Indoor Disconnect Switch
Switch Disconnect 1 Pole, 15kv, 630A, 50 (60) Hz
Horizontal Knee Type Disconnector (GW17)
High Voltage Horizontal Centre - Break Disconnector
Disconnect Switch V-Type Centre Breaker
Popular Disconnector Products
Interrupteur aé Rien à Commande Manuelle Rocking Disconnectors
High -Voltage Isolate Switch 40.5kv
Gw9 Series 12kv Outdoor High Voltage Disconnect Switch Hv
110kv 1250A Double Earthed Disconnector / Isolator Switch
Gw4 Series Outdoor AC Isolating Switch
Popular hzyddq Products
24kv 33kv High Voltage Dropout Fuse Cutout Switch
Polymer Insulator Surge Arrester
Load Break Disconnect Switch IEC Standard Gw17
Factory Price Surge Over Voltage Protection House for Transformer Substations
Electric Components MOV Varistor ZnO Varisotr
Ceramic Polymeric 36kv Lightning Arrester for Lightning Protection
Popular Insolated Switch Products
Outdoor AC System High-Voltage 252kv 200A to 4000A Disconnector Switch
24kv Outdoor Disconnector Switch Isolator
OEM Outdoor AC High Voltage 126kv 200A to 1000A Isolating Switch
12kv Isolating Switch with Manual Mechanism
Double-Column High Voltage Centre Break Disconnector
3 Phase Vertical Break Disconnector with Motor
Tags: Disconnect Switch, Disconnector, hzyddq, Insolated Switch