1.Simple Structure, reliable property, wide usage, economical and long-time life.
2.Complete specification and satisfy user’s different parameters requirements.
3.Connecting terminal and the electric pole is made by casting aluminum-alloy and section bar, having the good property of high-intensity, good flowing and anti-corrosion
4.In the galvanic circle, the section is the combination structure made by screw fix linking, having the good property of stable flowing, high reliability, simple change way and convenient adding volume way.
5.In the galvanic circle, the contact and finger is made by T2Y pure copper tap whose connecting part is coated by 30μ M silver.
6.Finger spring is made by the stainless steel and its design is the inside hiding and outside press structure which is convenient for testing and changing.
7.Bearing block is made by high-intensity casting steel (disposed by hot zinc coating), the height can be adjusted and have the function of damping.
8.All the operating rod and linking rod are supplied by manufacturer, which is convenient for loading, adjusting and testing.
9.Can be supplied as a whole above the ground according to user’s requirement.
No | Item | Technical parameter | |||||
1 | Rated Voltage kV | 72.5 | 123 | 145 | 245 | ||
2 | Rated Current A | 1250 1600 2000 2500 3150 4000 | |||||
3 | Rated Short Time withstand current and Time kA/s | 25~50/4 | |||||
4 | Rated Peak withstand current kA | 63~125 | |||||
5 | 1min power frequency withstand voltage (effective value) kV | To earth | 140 | 230 | 275 | 460 | |
To phase | 140 | 230 | 275 | 460 | |||
Across Isolating DS | 180 | 300 | 315 | 605 | |||
6 | Lightning Impulse wishstand voltage (peak value) kV |
To earth | 325 | 550 | 650 | 1050 | |
To phase | 325 | 550 | 650 | 1050 | |||
Across Isolating DS | 405 | 650 | 750 | 1200 | |||
7 | Rated mechanical terminal load N | Level of lateral load | 750 | 1500 | 1500 | 2000 | |
Level of vertical load | 500 | 1000 | 1000 | 1500 | |||
Vertical | 750 | 1000 | 1000 | 1250 | |||
8 | |||||||
9 | Max Man Operative Moment N.M | 200 | |||||
10 | Motor Drive operating mechanism control voltage V | AC220;DC110, 220 | |||||
11 | Motor Drive operating mechanism motor voltage V | AC220, 380;DC110, 220 |
Drawing:
We are China Outdoor Electric Switch Disconnector manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Disconnect Switch Products
15kv Outdoor Distribution Systems Disconnect Switch
Outdoor AC System High-Voltage 252kv 200A to 4000A Disconnector Switch
High -Voltage Isolate Switch 15kv 600A
Outdoor Single Pole Fused Recloser by-Pass Switches 15kv
Disconnect Switch 33kv High Voltage Outdoor Isolator Switch
Popular Disconnector Products
145kv Gw4 Outdoor Hv Disconnector/Disconnecting Switch
3 Poles Three Phase Isolators Switch
Manufacturer Supply Disconnector Switch 132kv Isolator
Single Pole Fused Recloser by-Pass Switches 15kv 600A
Gw38 High Voltage Disconnect Switch
Popular hzyddq Products
Jw-126 Outdoor Mounted Three - Poles High Voltage Isolating Switch
Thunder Arrester Polymeric Housed Gapless Lightning Arrestor up to 550kv
2016 New High Voltage Polymer Surge Arrestor
MOV Zinc Oxide Varistor Block for Hv Surge Arrester
Medium Voltage 3 Phase Isolating Switches
AC System Disconnect Switch for Power System
Popular Insolated Switch Products
12kv Isolating Switch with Manual Mechanism
24kv Outdoor Disconnector Switch Isolator
Outdoor AC System High-Voltage 252kv 200A to 4000A Disconnector Switch
Outdoor 3 Phase Isolating Switch of High Voltage
Medium Voltage 3 Phase Isolating Switches
Double-Column High Voltage Centre Break Disconnector
Tags: Disconnect Switch, Disconnector, hzyddq, Insolated Switch