Hx Series AC Arc Furnaces
Hx Series AC Arc Furnaces image
Get Latest Price Request a quote
Basic Info.
Product Description
Applications
HX series steelmaking DC arc furnaces are used for melting quality carbon steel and kinds of alloy steel. Their
normal capacities are from 3t to 100t.
Features
According to its power matching, HX series steelmaking AC arc furnaces can be divided into OP, HP and UHP;
According to its operation form, it can be divided into left and right operations. The type of roof is a kind of
spinning to add material. The whole apparatus is of a reasonable design, reliable operation and excellent
performance.
Description
· Furnace body
Tapping manners: Spout and EBT
Tubular water-cooled and traditional roof are available
· Tilting mechanism
· Electrode lifting mechanism
It can be realized by bogie movement lifting. And common copper tube arm or advanced water-cooled
conducting arm are available.
· Roof lifting mechanism
Integrated or separated foundation designs for your choice.
· Cooling-water monitoring and alarming system
· Hydraulic station and control valves system.
· Electric control system:
Automatic regulator of electrode lifting can be VVVF controlled or computer controlled. The later can equipped
with CRT displayer. The acting of all parts and interlooks is controlled by PLC.
Most advanced technologies of steelmaking arc furnace can be provided as request:
· Single-electrode A. C powering technology
· 50% less electrode consumption
· 50% less electric energy consumption
· Less flicker an disturbance on power network
· More uniform heating of liquid steel
· Electromagnetic stirring of liquid steel
· Copper-steel composite conductive electrode arm
· Tubular water-cool wall
· Tubular water-cool roof
· Eccentric bottom tapping (EBT)
· Microcomputer controller-motor type electrode regulator
· VVVF-motor type electrode regulator
· Energy-saving high current circuit
· Large section water-cooled cable
· Oxv-fuel burnel systems
Technical Data:
Model | Shell Ld (mm) | Steel Capacity (t) |
Transformer rated capacity (KVA) |
Premier Voltage (Kv) |
Secondary Voltage (Kv) |
Electrode diameter (mm) |
Electode Circle Diameter (mm) |
Cooling water consumption (m/h) |
Equipment weight (t) |
HX-0.5 | 2100 | 0.5 | 320 | 6 10 | 200-98 | φ150 | φ450 | 8 | 5 |
HX-1.5 | 2500 | 1.5 | 1250 | 6 10 | 210-104 | φ200 | φ650 | 14 | 9 |
HX-3 | 3000 | 3 | 2200 | 6 10 | 220-110 | φ250 | φ750 | 15 | 24 |
HX-5 | 3400 | 5 | 3200 | 6 10 | 240-121 | φ300 | φ850 | 15 | 34 |
HX-10 | 3500 | 10 | 5000 8000 | 10 | 260-139 | φ350 | φ950 | 20 | 74 |
HX-15 | 3800 | 15 | 8000 | 10 | 260-139 | φ350 | φ1000 | 25 | 85 |
HX-20 | 4200 | 20 | 10000 12500 | 35 | 280-100 314-116 | φ400 | φ1050 | 25 | 98 |
HX-30 | 4600 | 30 | 12500 16000 25000 | 35 110 | 314-116 353-137 | φ450 | φ1150 | 53 | 178 |
HX-40 | 5000 | 40 | 20000 31500 | 35 110 | 292-158 489-201 | φ500 | φ1250 | 80 | 205 |
HX-50 | 5200 | 50 | 25000 31500 40000 | 35 110 | 436-184 547-223 | φ500 | φ1300 | 133 | 224 |
HX-60 | 5500 | 60 | 40000 50000 | 35 110 | 547-223 610-250 | φ550 | φ1350 | 150 | 252 |
HX-75 | 5800 | 75 | 50000 63000 | 35 110 | 610-250 673-277 | φ600 | φ1400 | 180 | 274 |
HX-100 | 6400 | 100 | 50000 63000 80000 | 35 110 | 673-277 760-310 | φ600 | φ1450 | 230 | 294 |
HX-125 | 6800 | 125 | 63000 80000 1000000 | 35 110 | 760-310 880-330 | φ650 | φ1500 | 260 | 330 |
Our Best Service For You
1. | Pre sale service |
a. | make technical solution |
b. | send quotation, technical data sheet and drawing |
c. | prepare power transmission plan, testing plan and shipment plan |
2. | In sale service |
a. | supervise the manufacturing schedule totally in accordance with the plan |
b. | send photos to customer during every manufacturing process(hold point) |
c. | inform the customer one week before testing. |
3. | After sale service |
a. | installation and commissioning, training the workers |
b. | quick response within 12 hours any time |
c. | provide 12 months guarantee period normally. |
FAQ For You
1. Q: | What is your delivery time ? |
A: | Depend on the type of transformer. |
2. Q: | What is your payment term? |
A: | 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
3. Q: | What kind of standard you follow? |
A: | IEC, ANSI, GB, etc |
4. Q: | What kind of supporting documentation you can provide normally |
A: | Quotation, outline drawing, manufacturing plan, quality control plan testing plan, financial report, type test report(KEMA, CESI),reference list, etc |
5. Q: | What is your normal warranty period? |
A: | 12 months after transformer operation. |
6. Q: | Can u do installation and commission in user’s site? |
A: | Yes, we can send our installation team to user’s country for service. |
7. Q: | Do you have any experience in this kind of transformer? |
A: | Yes, we can provide reference list for check. |
Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Hx Series AC Arc Furnaces manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular cnville Products
Bwy Series Oil Temperature Indicator for Oil-Immersed Transforer
Ring Main Unit Metal-Clad Switchgear
Tap Changer /Transformer off Circuit Tap Changer /Transformer Load Switch
Lw36-126 (W) /T3150-40 High Voltage Sf6 Circuit Breaker
Bwr-04 Transformer Winding Temperature Thermometer Controller
Voltage Transformer for Gis Gas-Insulated Voltage Transformer