Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge image
Get Latest Price Request a quote
Basic Info.
Packaging & Delivery
Product Description
Product Description
At present, the process of overhead insulation below 10KV in urban and rural areas is very fast. However, in the distribution transformer area on the pole, there are many connection parts such as switches, arresters, connecting clips, and pillars, which bring many operating fault points, poor insulation and safety protection conditions, complicated installation and maintenance. There are a series of problems such as difficulty, high cost, and poor live working conditions. In order to deal with the above problems, it is necessary to transform some equipment and line connection methods of the distribution transformer system on the pole, so that it can achieve the purpose of simplifying the device and further increasing the operation safety. HY5WBG type synthetic jacketed zinc oxide arrester device has the function of strut, arrester, puncture and electrification, and grounding function. It has a multi-purpose structure. The use of this device can also reduce one arrester cross-arm (because of the use of the originally required pillar cross-arm), can reduce the three insulators used for fixing the sag, that is, seven peeling points, reduce construction time, and reduce six If the fault point is located, the purpose of simplifying the line device, further increasing the safety and reliability of operation, and making the line more concise and beautiful. This device integrates a variety of functions, and insulates the insulation that originally required seven peeling points into one.The design of the shield is reasonable and can truly achieve the whole insulation, creating favorable conditions for safety and live operation
Model Description
Product technical parameters
Product Structural features and scope of use
1. The core body and jacket of the arrester are molded into a compact whole without a cavity, which eliminates the moisture absorption caused by breathing and fundamentally eliminates the accident caused by the damping of the arrester chip.
2. The inside of the arrester adopts a special strengthening structure, which makes it have good mechanical properties and can also be used as an insulator
3. The synthetic jacket of the arrester is made of silicone rubber material, which makes it have strong anti-pollution performance and good explosion-proof performance. In addition, light weight and long service life
4. The arresters are designed and produced according to the class III heavy pollution resistance. The minimum creepage ratio of the insulating jacket is 25mm/KV, and the creepage distance is 320mm.
5. The overall structure of the arrester is optimized and has a combined function.
a. It has both grounding stems, which can meet the needs of electricity inspection and grounding, and can simplify the tower installation
b. The special reinforcement structure makes it have good mechanical properties and can double as a pillar insulator
c. The connection terminal block can segment the cable fault, reduce the power failure range, and has the function of breaking the knife switch
d. The use of full insulation design can effectively avoid the occurrence of accidents such as external force damage
6. The arrester device has the function of supporting pillars, connecting terminal busbar wiring, and electrical inspection and grounding. The connecting terminal busbar can segment cable faults, reduce the scope of power outages, and has the function of segmenting a knife switch.
Product Specifications and Production Process
Product implementation standards and user notices
The production standard of the product is GB11032-2000 (eqv IEC60099-4:1991) “AC No-gap Metal Oxide Surge Arrester”, JB/8952-2005 “Composite Jacket No-gap Metal Oxide Surge Arrester for AC System”
1. The arrester should be stored in a clean and dry room before installation and use. Must not be corroded by corrosive gases or liquids.
2. Before the arrester is put into operation, a preventive test should be carried out. After being put into operation, it should also be regularly (10KV and below arrester once every 5 years, 35KV and above arrester once every 2 years)
Do the following test and compare with the data before operation with reference to the attached table:
a. Measure the insulation resistance of the arrester
b. Measure the DC 1mA voltage of the arrester
c. Measure the leakage current of 0.75 times DC 1mA
Product details
Products real shot
A corner of the production workshop
Product packaging
Product application case
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular cnkcele Products
Jbtl 16-240mm^2 98*50*50mm Aluminum Parallel Trench Wire Clip
Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
Mgt 50-250mm Vertical Terminal Connectors Tubular Bus-Bar T-Connectors Clamp Substation Fitting
Popular High Voltage Fuse Products
Fuse Links Mv Type J Slotted (400 AMPS)
RW11 100A/200A Composite Slicone Rubber Dropout Fuse/High Voltage Fuse Cutout
33kv Drop out Fuse Assembly 100A /200A Porcelain Fuse Cut-out
Cowhide Split Leather Welding Gloves
Popular Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge Products
Popular Outdoor Drop out Fuse Products
Rn Series 3-40.5kv 50ka 2023 New Type Indoor Medium and High Voltage Fuses Made in China
RW11-10f 12/24kv Outdoor AC High Voltage Protection Switch Drop Fuse with Arc Extinguishing Cover
Hrw 12/35kv Outdoor High Voltage Protection AC Drop-out Fuse
RW11 Series 12kv 100/200A Outdoor High Voltage Protection Switch Drop-out Fuse
Hrw 12kv 24kv 100A 200A High Voltage Composite Drop-out Type Fuse Cutout Fuse Link
Tags: cnkcele, High Voltage Fuse, Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge, Outdoor Drop out Fuse