Insulated Wire PVC Electric Insulated Double Insulated Wire PVC Insulated Wire Winding Wire Electric
Insulated Wire PVC Electric Insulated Double Insulated Wire PVC Insulated Wire Winding Wire Electric image
Get Latest Price Request a quote
Quick Details
Product Details
Application
A. It can be applied to be installation and connection for electrical device, equipment power device, domestic appliance, instrument,lighting circuit, and automation device.
B. The feature of flame retardant cable is not easy to be fired and can control the flame into certain restriction and slow the fire speed after fire. So it can be applied to the occasion with high request of flame retardant.
C. Flame cable can be divided into 4 grade: A,B,C,D and the Grade A is the best flame retardant grade.
D. Beside the cable can transfer power at the normal condition, it can also keep a period of safe operation under fire. It can be applied for the occasion with request of fire resistance.
Pruduct Structure
Reference Data of the Product Structure: IEC 60227
1. 01(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (/km) |
Minumum Insulation Resistance at 70ºC (M·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
1.5 | 1 | 2.82 | 2.6 | 3.2 | 19.70 | 12.1 | 0.011 | 18 |
1.5 | 2 | 3.00 | 2.7 | 3.3 | 20.31 | 12.1 | 0.010 | 18 |
2.5 | 1 | 3.43 | 3.2 | 3.9 | 31.20 | 7.41 | 0.010 | 25 |
2.5 | 2 | 3.69 | 3.3 | 4.0 | 32.82 | 7.41 | 0.009 | 25 |
4 | 1 | 3.90 | 3.6 | 4.4 | 46.08 | 4.61 | 0.0085 | 33 |
4 | 2 | 4.20 | 3.8 | 4.6 | 47.45 | 4.61 | 0.0077 | 33 |
6 | 1 | 4.41 | 4.1 | 5.0 | 65.71 | 3.08 | 0.0070 | 42 |
6 | 2 | 4.77 | 4.3 | 5.2 | 67.19 | 3.08 | 0.0065 | 42 |
10 | 1 | 5.65 | 5.3 | 6.4 | 109.09 | 1.83 | 0.0070 | 58 |
10 | 2 | 6.13 | 5.6 | 6.7 | 113.07 | 1.83 | 0.0065 | 58 |
16 | 2 | 7.18 | 6.4 | 7.8 | 170.90 | 1.15 | 0.0050 | 78 |
25 | 2 | 8.92 | 8.1 | 9.7 | 268.52 | 0.727 | 0.0050 | 105 |
35 | 2 | 10.06 | 9.0 | 10.9 | 362.82 | 0.524 | 0.0043 | 130 |
50 | 2 | 11.81 | 10.6 | 12.8 | 492.15 | 0.387 | 0.0043 | 155 |
70 | 2 | 13.61 | 12.1 | 14.6 | 694.19 | 0.268 | 0.0035 | 200 |
95 | 2 | 15.93 | 14.1 | 17.1 | 959.23 | 0.193 | 0.0035 | 250 |
120 | 2 | 17.54 | 15.6 | 18.8 | 1197.15 | 0.153 | 0.0032 | 290 |
150 | 2 | 19.49 | 17.3 | 20.9 | 1472.95 | 0.124 | 0.0032 | 335 |
185 | 2 | 21.80 | 19.3 | 23.3 | 1846.14 | 0.0991 | 0.0032 | 390 |
240 | 2 | 24.83 | 22.0 | 26.6 | 2416.54 | 0.0754 | 0.0032 | 470 |
300 | 2 | 27.67 | 24.5 | 29.6 | 3023.55 | 0.0601 | 0.0030 | 540 |
400 | 2 | 31.06 | 27.5 | 33.2 | 3851.72 | 0.0470 | 0.0028 | 635 |
2.02(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
1.5 | 5 | 3.00 | 2.8 | 3.4 | 20.30 | 13.3 | 0.010 | 18 |
2.5 | 5 | 3.64 | 3.4 | 4.1 | 31.59 | 7.98 | 0.009 | 25 |
4 | 5 | 4.21 | 3.9 | 4.8 | 47.54 | 4.95 | 0.0070 | 33 |
6 | 5 | 4.81 | 4.4 | 5.3 | 67.42 | 3.3 | 0.0060 | 42 |
10 | 5 | 6.28 | 5.7 | 6.8 | 118.00 | 1.81 | 0.0056 | 58 |
16 | 5 | 7.20 | 6.7 | 8.1 | 169.44 | 1.21 | 0.0046 | 78 |
25 | 5 | 10.10 | 8.4 | 10.2 | 269.71 | 0.78 | 0.0044 | 105 |
35 | 5 | 11.23 | 9.7 | 11.7 | 364.35 | 0.554 | 0.0038 | 130 |
50 | 5 | 13.75 | 11.5 | 13.9 | 522.86 | 0.386 | 0.0037 | 155 |
70 | 5 | 15.40 | 13.2 | 16.0 | 720.89 | 0.272 | 0.0032 | 200 |
95 | 5 | 18.15 | 15.1 | 18.2 | 953.89 | 0.206 | 0.0032 | 250 |
120 | 5 | 19.70 | 16.7 | 20.2 | 1199.28 | 0.161 | 0.0029 | 290 |
150 | 5 | 21.10 | 18.6 | 22.5 | 1485.62 | 0.129 | 0.0029 | 335 |
185 | 5 | 24.03 | 20.6 | 24.9 | 1824.52 | 0.106 | 0.0029 | 390 |
240 | 5 | 26.70 | 23.5 | 28.4 | 2389.69 | 0.0801 | 0.0028 | 470 |
3.05(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
0.5 | 1 | 2.04 | 1.9 | 2.3 | 8.16 | 36.0 | 0.015 | 9 |
0.75 | 1 | 2.21 | 2.1 | 2.5 | 10.71 | 24.5 | 0.012 | 12 |
1 | 1 | 2.37 | 2.2 | 2.7 | 13.48 | 18.1 | 0.011 | 14 |
4.06(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
0.5 | 5 | 2.18 | 2.1 | 2.5 | 8.58 | 39.0 | 0.013 | 9 |
0.75 | 5 | 2.43 | 2.2 | 2.7 | 11.50 | 26.0 | 0.011 | 12 |
1 | 5 | 2.52 | 2.4 | 2.8 | 14.00 | 19.5 | 0.010 | 14 |
5.10(BVV)Cable
Core No.×Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BVV | Minimum | Maximum | BVV | |||||
2×1.5 | 1 | 9.36 | 7.6 | 10.0 | 98.94 | 12.1 | 0.011 | 18 |
2×1.5 | 2 | 9.72 | 7.8 | 10.5 | 103.09 | 12.1 | 0.010 | 18 |
2×2.5 | 1 | 10.56 | 8.6 | 11.5 | 130.99 | 7.41 | 0.010 | 25 |
2×2.5 | 2 | 11.08 | 9.0 | 12.0 | 138.55 | 7.41 | 0.009 | 25 |
2×4 | 1 | 11.50 | 9.6 | 12.5 | 171.31 | 4.61 | 0.0085 | 33 |
2×4 | 2 | 12.10 | 10.0 | 13.0 | 179.24 | 4.61 | 0.0077 | 33 |
2×6 | 1 | 12.52 | 10.5 | 13.5 | 218.41 | 3.08 | 0.0070 | 42 |
2×6 | 2 | 13.24 | 11.0 | 14.0 | 227.77 | 3.08 | 0.0065 | 42 |
2×10 | 1 | 15.64 | 13.0 | 16.5 | 361.55 | 1.83 | 0.0070 | 65 |
2×10 | 2 | 16.70 | 13.5 | 17.5 | 384.71 | 1.83 | 0.0065 | 65 |
2×16 | 2 | 18.80 | 15.5 | 20.0 | 532.01 | 1.15 | 0.0052 | 87 |
2×25 | 2 | 22.64 | 18.5 | 24.0 | 798.61 | 0.727 | 0.0050 | 110 |
2×35 | 2 | 25.72 | 21.0 | 27.5 | 1055.97 | 0.524 | 0.0044 | 140 |
3×1.5 | 1 | 9.8 | 8.0 | 10.5 | 124.61 | 12.1 | 0.011 | 15 |
3×1.5 | 2 | 10.19 | 8.2 | 11.0 | 129.71 | 12.1 | 0.010 | 15 |
3×2.5 | 1 | 11.10 | 9.2 | 12.0 | 168.94 | 7.41 | 0.010 | 21 |
3×2.5 | 2 | 11.66 | 9.4 | 12.5 | 178.67 | 7.41 | 0.009 | 21 |
3×4 | 1 | 12.12 | 10.0 | 13.0 | 228.20 | 4.61 | 0.0085 | 28 |
3×4 | 2 | 12.76 | 10.5 | 13.5 | 238.21 | 4.61 | 0.0077 | 28 |
3×6 | 1 | 13.62 | 11.5 | 14.5 | 307.47 | 3.08 | 0.0070 | 36 |
3×6 | 2 | 14.40 | 12.0 | 15.5 | 319.96 | 3.08 | 0.0065 | 36 |
3×10 | 1 | 16.52 | 14.0 | 17.5 | 476.74 | 1.83 | 0.0070 | 56 |
3×10 | 2 | 17.67 | 14.5 | 19.0 | 507.40 | 1.83 | 0.0065 | 56 |
3×16 | 2 | 20.34 | 16.5 | 21.5 | 726.41 | 1.15 | 0.0052 | 74 |
3×25 | 2 | 24.05 | 20.5 | 26.0 | 1074.22 | 0.727 | 0.0050 | 98 |
3×35 | 2 | 27.31 | 22.0 | 29.0 | 1431.17 | 0.524 | 0.0044 | 120 |
4×1.5 | 1 | 10.51 | 8.6 | 11.5 | 159.43 | 12.1 | 0.011 | 15 |
4×1.5 | 2 | 10.95 | 9.0 | 12.0 | 165.62 | 12.1 | 0.010 | 15 |
4×2.5 | 1 | 11.96 | 10.0 | 13.0 | 216.48 | 7.41 | 0.010 | 21 |
4×2.5 | 2 | 12.59 | 10.0 | 13.5 | 228.55 | 7.41 | 0.009 | 21 |
4×4 | 1 | 13.49 | 11.5 | 14.4 | 296.50 | 4.61 | 0.0085 | 28 |
4×4 | 2 | 14.22 | 12.0 | 15.0 | 309.46 | 4.61 | 0.0077 | 28 |
4×6 | 1 | 15.13 | 12.5 | 16.0 | 398.92 | 3.08 | 0.0070 | 36 |
4×6 | 2 | 15.99 | 13.0 | 17.0 | 414.94 | 3.08 | 0.0065 | 36 |
4×10 | 1 | 17.93 | 15.5 | 19.0 | 594.97 | 1.83 | 0.0070 | 56 |
4×10 | 2 | 19.20 | 16.0 | 20.5 | 633.59 | 1.83 | 0.0065 | 56 |
4×16 | 2 | 22.14 | 18.0 | 35.5 | 916.62 | 1.15 | 0.0052 | 74 |
4×25 | 2 | 27.09 | 22.5 | 28.5 | 1414.08 | 0.727 | 0.0050 | 98 |
4×35 | 2 | 28.84 | 24.5 | 32.0 | 1826.39 | 0.524 | 0.0044 | 120 |
5×1.5 | 1 | 11.31 | 9.4 | 12.0 | 191.08 | 12.1 | 0.011 | 15 |
5×1.5 | 2 | 11.79 | 9.8 | 12.5 | 198.39 | 12.1 | 0.010 | 15 |
5×2.5 | 1 | 12.93 | 11.0 | 14.0 | 260.97 | 7.41 | 0.010 | 21 |
5×2.5 | 2 | 13.63 | 11.0 | 14.5 | 275.46 | 7.41 | 0.009 | 21 |
5×4 | 1 | 15.00 | 12.5 | 16.0 | 370.96 | 4.61 | 0.0085 | 28 |
5×4 | 2 | 15.81 | 13.0 | 17.0 | 387.08 | 4.61 | 0.0077 | 28 |
5×6 | 1 | 16.37 | 13.5 | 17.5 | 482.44 | 3.08 | 0.0070 | 36 |
5×6 | 2 | 17.34 | 14.5 | 18.5 | 501.42 | 3.08 | 0.0065 | 36 |
5×10 | 1 | 19.50 | 17.0 | 21.0 | 725.11 | 1.83 | 0.0070 | 56 |
5×10 | 2 | 20.94 | 17.5 | 22.0 | 771.84 | 1.83 | 0.0065 | 56 |
5×16 | 2 | 24.57 | 20.5 | 26.0 | 1142.09 | 1.15 | 0.0052 | 74 |
5×25 | 2 | 29.61 | 24.5 | 31,5 | 1732.02 | 0.727 | 0.0050 | 98 |
5×35 | 2 | 33.09 | 27.0 | 35.0 | 2272.06 | 0.524 | 0.0044 | 120 |
Notes: Conductor Types–1st type is solid conductor;2nd type is stranded conductor;5th type is stranded soft conductor;
which are suitable for different applications.
We are China Insulated Wire PVC Electric Insulated Double Insulated Wire PVC Insulated Wire Winding Wire Electric manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 450/750V Cable Products
Ho7z-R 450/750V Low Smoke Cable
450/750V Electric Wires VV Model Building Flexible Electrical Wires
BV/BVVB/BVV PVC Insualted Electrical Wire (Housing Electrical Wire)
0.5-6.0mm PVC Insulated Copper Core BV Electric Wire Cable for Home and Office
Cu/PVC 450/750V Cable Electrical Wire Roll Length 100m From Shandong Newluxing Cable Factory
Plastic Insulation Control Cable 300/500V
Popular Cable Products
SWA Cable - BS6724 Steel Wire Armoured LSZH
Nylon Sheath Thhn Thwn Thwn-2 2 AWG Electrical Wire
Low Voltage Aluminum Conductor XLPE PE PVC Insulation Overhead Service ABC Cable
3 Core 300mm2 XLPE Power Cable Medium Voltage Yjv 8.7-15kv
Professional 450/750V PVC Insulated Electrical Wire Prices
3.6/6kv Rubber Insulated and Sheathed Mining Cable
Popular Power Cable Products
Factory Supply Underground Cable and Lshf Cable Fire Resistant Cable
Flexible Electrical 1mm Copper Wire Insulated Power Cable PVC Round Wire
IEC ASTM DIN CSA British Standard Aluminum Wire Armoured Middle Voltage Power Cable (YJV72 26/35KV)
XLPE Insulation Power Cable with Aluminum Alloy Interlocked Armor
Copper Aluminum Conductor PVC Sheathed Electrical Wire Power Cable
Copper Core XLPE Insulated PVC Sheathed Power Cable, Hv XLPE Cable, Wires, Cross-Linked 1*500mm2
Popular wuhancable Products
Overhead Aluminium Bare ACSR Conductor for Transmission Line
Yjv Yjv22 Yjv32 XLPE/Armoured Cable with Low Voltage
AAAC Conductor All Aluminium Alloy Conductor ASTM Standard 1/0
19 No 5AWG Aluminium Clad Steel Wire Strand Acs
Aluminum Conductor Steel Reinforced. ACSR Conductor, Power Transmission Line
Power/Copper/Control/ABC/PVC Cable
Tags: 450/750V Cable, Cable, Power Cable, wuhancable