Insulator 500kv 12.5kn_DSC3521--1

China 
                Insulator 500kv 12.5kn_DSC3521--1
              manufacture and supplier

Insulator 500kv 12.5kn_DSC3521--1 image

Get Latest Price Request a quote

Basic Info.

Standard
IEC IEEE

Transport Package
Cartons Pallets Wooden Case

Specification
IEC282-2 IEEEc37-41

Trademark
OEIpower

Origin
China Nanyang

HS Code
85351000

Production Capacity
100000

Product Description


DESIGN EXPULSION FUSEGEAR

 
The complete assemblies shall be rated 105°C for normal circuit conditions.  Further they shall meet the following electrical test requirements.

A.   Performance Characteristics
 
1.      Voltage
 
a. BIL:  170kV, 1.2 x 50 microsecond wave.
 
b.         AC Withstand: 70kV, 50Hz, 1 minute; dry and wet.
 
2.      Current
 
a. Continuous Operation:  100A minimum
 
b.         Rated interrupting current of Expulsion fusegear:
 
Prospective RMS symmetrical amperes: 4000A, i.e. 6 tests of test Series No. 1 from total series of 16 tests per Table IVA IEC 602822 at 4,000 amperes RMS symmetrical.
 
3.      Low Current Interruption
 
The Expulsion fusegear shall meet the requirements of IEC 602822 Clause 13, and shall be tested to interrupt down to 15 amperes applied to a 6K fuse link.
 
4.      Fuse Link Range and Class
 
The Expulsion fusegear shall be suitable in all respects for fuse links within the range 1 to 100 amps per IEC and NEMA standards.
 
B.   Interchangeability
 
The fuse holder (tube) of a fuse isolator shall be dimensionally compatible with a universal fuse link of corresponding rating and with a universal fuse tube.(e.g. fuse links manufactured by Hubbell Power Systems and S&C Electric Company of North America)
 
C.   Insulators
 
The insulators shall be of solid glazed porcelain type and be birdproof.  They shall meet the electrical and mechanical characteristics as shown in IEC Standard Publication 60383.  Insulators shall be based on rated voltage of 33kV.
 

 

1.         The support insulators must withstand dry and wet test voltages at 50Hz, sustained for one minute of not less than:
 
a.         70kV to earth and between poles and
b.         80kV across the isolating distances, re IEC 600602, Section 3
 
The Supplier shall also give the following information in the schedule.
 
c.         The minimum dry flashover voltage value
d. The minimum wet flashover voltage value
e. The puncture voltage at 50Hz.
 
2.      Radio Interference Voltage
 
The maximum radio interference voltage shall be 250 microvolts measured in accordance with IEC 60437.
 
D.   Clearance
 
The Supplier shall give the following information in the schedule:
 
1.      Minimum phase/phase clearance
 
2.      Minimum phase/earth clearance.
 
E.    Creepage Distance
 
Minimum leakage distance to ground shall be 900mm.
 
F.    Construction
 
1.      Main assembly
 
a.         The main assembly may be mounted on a 2 insulator channel base arrangement.  The insulators shall be porcelain and bird proof.
 
Top and bottom contact subassemblies and mounting fitting shall be potted into the porcelain insulators.  The upper fixed contacts shall positively latch.  (See Figures 1 and 2).
 
b.         All contacts shall be designed to give permanent current carrying capacity at rated current after exposure to marine climate for up to 20 years.  All current carrying components shall be of copper or copper alloy.  Terminals shall be suitable for conductor up to 265mm2 Al/Cu.
 

c.         Contacts shall be heavily silver clad on each side of each interface.  Embossed surfaces with wiping action are preferred.
 
d.         Ferrous components shall be stainless steel or galvanised.  The Supplier shall state weight/thickness of zinc coating on the attached Schedule.
 
e.         The Expulsion Fusegear shall be provided with a permanently fitted loadbreak device.                       
                                                               
f.          The assembly shall be designed such that the fuse tube can be closed without using undue care even when the closing force is applied from an angle.
 
g.         The angle of fuse tube relative to the vertical shall be filled in on the attached schedule.
 
h.         The insulator shall preferably be marked with the rated voltage and the minimum basic insulation level
 
IEEE/NEMA brackets shall be provided.
 
2.      Fuse Tube Assembly
 
a.         The fuse tube shall be capable of accepting IEC/NEMA fuse links up to a maximum continuous current rating of 100 amperes.
 
b.         The toggle mechanism shall provide locking action to protect the fuse link from shock.  A spring assisted flipper shall assist arc interruption by withdrawal of the fuse tail.
 
c.         The fuse tube cap may be the expendable type.
 
d.         A lifting eye shall be provided on the fuse tube and designed for use with hookstick.
 
e.         The fuse tube shall be permanently marked with the following:  Supplier/Manufacturer; model; maximum continuous current rating; rated maximum voltage phase to phase; rated symmetrical amperes interrupting per IEC requirements.
 
G.   Operating Gear
 
For Single Pole Units operation will be by means of the Purchaser’s standard operating hot-stick, and loadbreak tool to ensure existing practice can continue.      
 

We are China Insulator 500kv 12.5kn_DSC3521--1 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Chave Fusivel Polimerica Products

Fuse Link, 30 AMP - K

Design Expulsion Fuse (PRW-15)

_DSC3521--1

Popular Insulator 500kv 12.5kn_DSC3521--1 Products

  • No related articles
  • Popular jgtrade1 Products

    D-Iron Complete with Bolt&Nut

    Outdoor Expulsion Drop-out Polymer Distribution Fuse Cutout 27-36kv

    Spacers for Two-Bundle Conductor Type Mrj, Suitable for Large Cross-Sectional Conductor

    Disconnector Switch 12kv

    220kv Polymer Sation Post Insulators

    Zinc Oxide Varistor Metal Oxide Varistor ZnO Blocks Zinc Oxide Discs Metal Oxide Discs MOV Moa Surge Arrester Lightning Arrester D42 D45 D46 D48 D52 D60

    Popular Loadbreak Cutout Products

    High -Voltage Fuse Cutout 36kv

    Polymer Cutouts Porcelain Cutouts 12-36kv

    Terminal Connectors for Double Large Cross-Sectional Conductors Type SL, Bolted Type

    Switch Disconnector Fuse Holder, 15 Kv - 200 AMP, Without Arc Chute

    Best Price36kv 100A Ceramic Types Drop out Fuses Cutout/Cut out Fuse

    Top Sales Safe Outdoor High Voltage Switches Porcelain Fuse Cutout

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION