High Voltage Substation Lightning Arresters Manufacturers of 66kV Surge Arrester
0.25kV~750kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Surge Arresters’ Technical Parameters:
| Type | Y10W5-66/176 |
| Rated voltage———kV | 66 |
| MCOV —————-kV | 52.8 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 221 |
| 8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
| 1mA D.C reference voltage (kV) | 96 |
| Line discharge level | 1 |
| 2mS long duration impulse current A | 400 |
| 4/10μS High current impulse kA | 100 |
| Lightning impulse withstand kV | 325 |
| Power frequency voltage withstand(dry/wet)kV | 140 |
| 0.1S TOV————–kV | 79.2 |
| 1S TOV—————-kV | 75.9 |
| 10S TOV—————kV | 72.6 |
| 1200S TOV————-kV | 66 |
| Creepage distance —-mm | 2500 |
| Material employed in series non-linear resistor | Zinc Oxide |
| Working condition: | Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | ||||||||
| 48HZ<Rated frequency<62HZ | ||||||||
| Power frequency voltage should not be more than continuous running voltage | ||||||||
| Max wind speed should be less than 35m/s | ||||||||
| Earthquake intensity should be less than 7 degree | ||||||||
| If used in contamination area, should be noted in advance. | ||||||||
Lightning Arresters Production:
We are China Insulator Surge Protector Surge Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Arrester Products
Good Quality Line Distribution Lightning Surge Arrester
11kv 20ka-40ka DC500V Solar Surge Arrester
Electrical Item List Composite Polymeric Housed MOV Arrester
Transformer Substation High Voltage 200 Ka Lightning Arrester Symbol
High Voltage Polymer Surge Arrestor Lightning Arrester Price
110kv Metal Oxide Lightning Arrester
Popular hzyddq Products
18kv/20kv Innvoation Electrical Substation Class Surge Arrester Lightning
Medium Voltage 3-36kv Silicone Mcov 17kv Lightning Diverter with Disconnector
Electric Appliance Components ZnO Varisotr Block
252kv 3 Pole High Voltage Disconnectors
Surge Protection Surge Arrester Suppressor
China Manufacturer Outdoor 5ka Polymeric Gapless Surge Arresters
Popular Surge Arrester Products
Polymer Housed Transformer Protector Arrestor Lightning
Protective Equipments, Live Part Cover&Animal Protectors
Hy5wz-10/27 Zinc-Oxide Arrester
5ka Yh10W 12kv Silicon Rubber Surge Arrester
Popular Surge Protector Products
132kv Transmission Line Composite Polymer Silicone Zinc Oxide Arresters
Transmission Line Type Coaxial Lightning Current Metal-Oxide Surge Arrestor
Rated Voltage 27kv Discharge Class 1 Lightning Arrester for Substation
Fuyang Electrical Equipment Supplies Moa 132kv Metal Oxide Arrester
132kv Silicone ZnO Surge Protector for 500kv Transmission Lines
Outdoor High Voltage Electrical Equipment Supplies Porcelain ZnO Surge Arrestor
Tags: Arrester, hzyddq, Surge Arrester, Surge Protector