Iraq Underground Cable 3X150mm2 18/30kv Power Cable
Iraq Underground Cable 3X150mm2 18/30kv Power Cable image
Get Latest Price Request a quote
Basic Info.
Product Description
Product Description
Standards of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
The cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.
Application of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial re-place of PVC insulation or XLPE power cable.
Type & Designation of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Type | Description | Applications |
N2XY/N2XSEY NA2XY/NA2XSEY |
Cu or AL conductor XLPE insulated PVC sheathed power cables. | For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts. |
N2X2Y/N2XSE2Y NA2X2Y/NA2XSE2Y |
Cu or AL conductor XLPE insulated PE sheathed power cables. | |
N2XBY/N2XSEBY NA2XBY/NA2XSEBY |
Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. | For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit. |
N2XB2Y/N2XSEB2Y NA2XB2Y/NA2XSEB2Y |
Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables. | |
N2XRY/N2XSERY NA2XRY/NA2XSERY |
Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. | For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces. |
N2XR2Y/N2XSER2Y NA2XR2Y/NA2XSER2Y |
Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables. |
Cable Properties of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
Special features which we can offer for LV and MV cables:
* Watertight construction (both radial and longitudinal).
* Resistant to heavy vibration.
* Available in long delivery lengths to reduce number of joints.
* Corrosion-free screen area.
* Copper or aluminum conductor up to 2500mm².
* Different options for outer PE jackets (LDPE, MDPE & HDPE).
* Different options for PVC, LSF, LSZH & FRPVC, being anti-termite or UV resistant as per
BS 7835, IEC 60332 etc.
* Strippable insulation screen.
* Increased armour conductivity by insertion of hard drawn copper wires in armour.
The maximum rated temperature of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
XLPE insulated,the maximum operating temperature of conductor shall exceed 90ºCwhen the cable is used for long not period. The temperature of conductor shall not exceed 250ºC at short circuit for 5 seconds.
PVC insulated,the maximum operating temperature of conductor shall exceed 90ºC or 70 ºC when the cable is used for long not period. PVC insulated the temperature of conductor shall not exceed 160ºC at short circuit for 5 seconds.
Installation requirement of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
The installation of cable is not limited by the difference of elevation along the route. The ambient temperature should not be below 0ºC during installation. The permissible bending radius for cable shall be complied with the following regulations:
For single-core: R>20(D+d) +/-5%
For multi-core: R>15(D+d) +/-5%
Where:R-bending radius (mm) , D-overall diameter of the cable (mm) , d-diameter of conductor (mm).
Single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducs.
Rated voltage, No. of core and range of sectional area
Rate Voltage(kv): 0.6/1kV 1.8/3kV 3.6/6kV 6/10kV 8.7/15kV 12/20kV
18/30kV 21/35kV
Equivalent to : 0.6/1kV 1.9/3.3kV 3.8/6.6kV 6.35/11kV 8.7/15kV 12.7/22kV
19/33kV 21/35kV
No. of core and sectional area(mm2):
1 Core 1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200
50-1200
2 Core 1.5-185 25-185
3 Core 1.5-400 25-400 25-400 25-400 35-400 50-400 50-400
50-400
4 Core 2.5-400 25-400
5 Core 2.5-400 25-400
We are China Iraq Underground Cable 3X150mm2 18/30kv Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
Cu / Mica / XLPE / PVC 0.6/1kv 4X240mm2 Fire Resistant Cable XLPE Electricity Power Cable
2000V 600 Kcmil Photovoltaic System Sunlight Resistant Solar Power PV Solar Cable
DC Voltage Drop Installed ABC Cable
0.6/1.0kv Aluminum Conductor XLPE/PE Insulated 3*16sqmm Overhead Electric Cable ABC Cable
0.5mm2 Electrical Cable Wire PVC Armoured Instrumentation Zr-Kvvp Control Cable
Popular Iraq Underground Cable 3X150mm2 18/30kv Power Cable Products
Popular jpcable99 Products
High Quality Duplex Service Drop AAC-Aluminum Conductor (ABC Cable)
Turkey ACSR Aluminum Conductor ASTM B 232 Cable
Stranded Aluminum Clad Steel Wire (ACS)
Mv Voltage XLPE Insulated Swa Armoured Electric Cable, Power Cable
High Quality Low Voltage 0.6 / 1kv XLPE Insulated Power Cable
Popular Power Cable Products
Electrical Cable BV BVV Wire 450/750V Solid Copper Conductor Building Wire
ACSR Dog Conductor/ACSR Power Cable/AAC Electric Wire
6/10kv Aluminum Medium Voltage Power Cable 3 Cores Cables
Copper Wire PVC Insulation Nyy Power Cable
Tags: Cable, Iraq Underground Cable 3X150mm2 18/30kv Power Cable, jpcable99, Power Cable