Load Break Fuse 30kv

China 
                        Load Break Fuse 30kv
                      manufacture and supplier

Load Break Fuse 30kv image

Get Latest Price Request a quote

Quick Details

Load Break Fuse 30kv

PRW-30KV

IEC IEEE

Fuse Link

T K

Circle

High Voltage

Distribution

High

OEIpower

Cartons Pallets Wooden Case

IEC282-2 IEEEc37-41

China Nanyang

85351000

Product Details

CUT-OUT

Gama 20 kV a 36 kV

– Circuito Principal 200 A
– Ith 8 kA.
– Montaje Vertical
– Tubo Fusible de 100 A
– Norma CEI 282-2

– Tubo Fusible compatible con los
estándar norteamericanos.
– Este modelo permite el montaje
de la Autoválvula directamente
sobre la escuadra de fijación.
– Eslabones fusible:
de 2 Amp. a 100 Amp.
– Porcelana de color gris, efecto
Antivandálico.

— Montaje sencillo gracias a sus
tornillos de fijación anti-giro.
– No es necesaria ninguna
herramienta para cambiar el
eslabón

La base cortacircuitos en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.
Incorpora un tubo fusible con capacidad para eslabones de hasta 100A
, y es totalmente intercambiable con los modelos de una columna y
modelos de otros fabricantes.
El interior del tubo portafusible está constituido por un recubrimiento
vegetal lo que le confiere un poder de extinción superior a otros
modelos (según fabricante).

El Seccionalizador en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.

Gama:
15 , 24 y 36 kV
12 – 25 – 40 – 63 -100 – 140 A
Número de Defectos: 1 , 2 (Estándar) , 3.
Tiempo de Regeneración : Min. 30s.

Principales Características :
Dispositivo Autoalimentado. Utilización conjunta con Interruptores automáticos.
Importante reducción en los costes derivados de mano de obra y sustitución de fusible de los Cut-Out
convencionales derivados de fallos transitorios, ocasionados por tormentas eléctricas , accidentes
vegetales , etc…
Ausencia de Arcos y desgaste en los contactos.
Reutilización del equipo tras su rearme manual y acoplamiento en su base.

TYPE "OEI" "PRW" STANDARD CUTOUT DISTRIBUTION TECHNICAL SPECIFICATION
The Fuse Cutout type DHE was developed to operate in overhead distribution systems rated at 12-15 kV and 15-27,kV or 27-38 kV grounded systems with 100 or 200 A nominal currents.
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI PRW can be applied on all three-phase system rated at or below the maximum operational rating of the cutout. In highly polluted environments or environments with high levels of salinity, a cutout may be used with a higher nominal rating than
that of the system where it is being installed, where the insulator will have a greater leakage distance to ground, allowing for
increased safety against discharge. For an even better protection against abrasions, the hardware may be supplied in stainless

steel. The fuse cutout type OEI PRW has attachment hooks in aluminum.
The Fuseholder has a stainless steel flipper, which associated with a spring doesn’t allow the fuse link to be subject to traction
forces of over 3 Kgf, especially during closing. This me chanism also allows for high speed fuse link separation. The fuse cutout
type OEI PRW allows for the insertion of the fuse tube in a precise man ner and always in perfect alignment, due to the large distance
between the grunion pocket. Lower contact, silver-to-silver, provide du el current path, independent of hinge pivot. Stainless-steel
back-up springs prevent arcing when tube rises in hinge during recoil. The fuse cutout type OEI PRW may be transformed into a DICONNECT up to 300 A, by simply changing the fuse tube for an electrolytic copper blade.
The DHE Fuse Cutouts conform to ANSI and IEC standards, with independent tests performed At:
CPRI Always use quality fuse links. Only they can assure excellent performance.

We are China Load Break Fuse 30kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Cut out Products

Outdoor Expulsion Drop-out Polymer Distribution Fuse Cutout

Cutout Fuse 27kv (PRW-38)

Clevis, Ball; Steel; Hot-DIP Galvanized.

Pull Hoop

Copper Flexible Stud Connectors Type Mst

Drop out Fuses13kv

Popular Fuse Products

RW-15 High Voltage Fuse Cutout Power Tool

15-35kv Polymer Composite Dropout Fuse Cutout

Fprw-11 Drop-out Fuse Cutout;

Fsc-1 Medium Voltage Protection Porcelain Dropout Fuse Cut out

Enclosed Type Composite Polymer Drop-out Fuse Cut out Fuse

High Voltage Dropout Fuse or Fuse Cutout (Vc-12) , Silicon Fuse Cutout, Fuse Cutout

Popular Interrupter Products

Cable Distribution Box

27kv Load Break Cutout Fuse

Switch Disconnector Fuse Holder, 21 Kv - 200 AMP, Without Arc Chute

Line Tap Connector Split Bolt 100mm ² (MO-5/8)

_DSC3518

Los Cortacircuitos De Expulsió N Cut-out

Popular jgtrade1 Products

Load Break Cut Outfuse 33kv

Yh10W-192, 192kv 10ka Surge Arrester

Eye Bolt and Nut M20 X 350

Strain Clamps for Aacsr Hydraulic Compression Type

Gw High Voltage Isolation Disconnecting Outdoor Type Disconnector Switch

Safety Rope

Tags: , , ,