Low Voltage Cu/Al Core XLPE Insulated Steel Tape Armored Power Cable
Low Voltage Cu/Al Core XLPE Insulated Steel Tape Armored Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
Low Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Number Of core: 1core to 5 cores, 3+1 cores, 3+2 cores, 4+1 cores
Remarks: Including products for flame retardant, fire resistant and termite-proof
Packing: Export wooden drums
Workshop:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on;Only the halogen free cables shall be generally produced complied with IEC61034 and 60754.
Designing and manufacturing special power cable according to the other standards required by the
1)0.6/1kV, Single Core, Cu or Al/XLPE/PVC Power Cable;
0.6/1kV, Single Core, Cu or Al/XLPE/PVC/AWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Diameter of Al Wires | Nominal Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight | |||||
| Cu Conductor | Al Conductor | |||||||||||
| AWA | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA | |||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
| 1.5 | 1.6 | 0.7 | – | – | 1.4 | – | 5.7 | – | 44 | – | – | – |
| 2.5 | 2.0 | 0.7 | – | – | 1.4 | – | 6.2 | – | 57 | – | – | – |
| 4 | 2.6 | 0.7 | – | – | 1.4 | – | 6.7 | – | 74 | – | – | – |
| 6 | 3.1 | 0.7 | – | – | 1.4 | – | 7.3 | – | 96 | – | – | – |
| 10 | 3.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 7.9 | 12.4 | 134 | 235 | 74 | 175 |
| 16 | 4.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 8.9 | 13.4 | 196 | 307 | 99 | 209 |
| 25 | 6.0 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 10.6 | 15.1 | 289 | 417 | 139 | 267 |
| 35 | 7.1 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 11.7 | 16.2 | 382 | 522 | 172 | 309 |
| 50 | 8.4 | 1.0 | 1.0 | 1.25 | 1.4 | 1.5 | 13.2 | 18.7 | 503 | 710 | 220 | 427 |
| 70 | 10.0 | 1.1 | 1.0 | 1.25 | 1.4 | 1.5 | 15.0 | 20.5 | 702 | 936 | 293 | 522 |
| 95 | 11.7 | 1.1 | 1.0 | 1.25 | 1.5 | 1.5 | 16.8 | 22.4 | 950 | 1209 | 384 | 638 |
| 120 | 13.3 | 1.2 | 1.0 | 1.6 | 1.5 | 1.6 | 18.6 | 25.1 | 1186 | 1531 | 469 | 806 |
| 150 | 14.5 | 1.4 | 1.0 | 1.6 | 1.5 | 1.6 | 20.4 | 26.7 | 1458 | 1820 | 567 | 923 |
| 185 | 16.4 | 1.6 | 1.0 | 1.6 | 1.5 | 1.7 | 22.7 | 29.2 | 1810 | 2219 | 698 | 1105 |
| 240 | 18.7 | 1.7 | 1.0 | 1.6 | 1.6 | 1.8 | 25.4 | 31.9 | 2348 | 2802 | 889 | 1335 |
| 300 | 20.4 | 1.8 | 1.0 | 1.6 | 1.7 | 1.8 | 27.4 | 33.7 | 2917 | 3393 | 1091 | 1568 |
| 400 | 23.2 | 2.0 | 1.2 | 2.0 | 1.8 | 2.0 | 30.9 | 38.5 | 3713 | 4377 | 1379 | 2043 |
| 500 | 26.4 | 2.2 | 1.2 | 2.0 | 1.9 | 2.1 | 34.7 | 42.3 | 4770 | 5512 | 1767 | 2510 |
| 630 | 30.0 | 2.4 | 1.2 | 2.0 | 2.1 | 2.2 | 39.1 | 46.5 | 6105 | 6914 | 2248 | 3058 |
| 800 | 34.0 | 2.6 | 1.4 | 2.5 | 2.2 | 2.4 | 43.6 | 52.6 | 7893 | 9008 | 2867 | 3981 |
| 1000 | 41.4 | 2.8 | 1.4 | 2.5 | 2.3 | 2.5 | 51.6 | 60.8 | 10189 | 11524 | 3690 | 5025 |
Note:
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 800mm2 are compact round condctor.
1000m2 should be compact round segments conductor.
UnAr: Unarmoured/AWA: Aluminum Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(2) 0.6/ 1kV ,Two Cores,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Two Cores,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Two Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight | |||||||||||
| Cu Conductor | Al Conductor | |||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | |||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
| 1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 10.2 | 13.0 | 14.7 | 110 | 227 | 325 | – | – | – |
| 2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.2 | 14.0 | 15.7 | 142 | 270 | 378 | – | – | – |
| 4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.2 | 15.0 | 16.7 | 181 | 321 | 438 | – | – | – |
| 6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.4 | 16.2 | 17.9 | 233 | 386 | 516 | – | – | – |
| 10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.3 | 1.7 | 1.5 | 1.7 | 14.8 | 17.6 | 20.2 | 315 | 483 | 763 | 194 | 363 | 643 |
| 16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.3 | 1.7 | 1.5 | 1.7 | 16.9 | 19.6 | 22.3 | 455 | 646 | 963 | 259 | 450 | 767 |
| 25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 20.2 | 23.0 | 26.3 | 646 | 892 | 1413 | 363 | 591 | 1112 |
| 35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 22.5 | 25.2 | 28.6 | 857 | 1110 | 1682 | 434 | 683 | 1242 |
| 50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.6 | 28.3 | 31.7 | 1123 | 1411 | 2061 | 555 | 838 | 1474 |
| 70 | 10.0 | 1.1 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.9 | 22.7 | 25.6 | 29.1 | 1427 | 1692 | 2295 | 591 | 836 | 1382 |
| 95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.2 | 2.0 | 1.9 | 1.7 | 2.0 | 25.8 | 28.6 | 33.3 | 1935 | 2222 | 3132 | 782 | 1050 | 1914 |
| 120 | 13.3 | 1.2 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 29.2 | 33.6 | 36.7 | 2431 | 3072 | 3777 | 971 | 1573 | 2226 |
| 150 | 14.5 | 1.4 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.2 | 31.9 | 36.5 | 39.3 | 2984 | 3696 | 4450 | 1171 | 1845 | 2545 |
| 185 | 16.4 | 1.6 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.1 | 2.4 | 36.5 | 41.2 | 45.4 | 3721 | 4545 | 5840 | 1461 | 2246 | 3442 |
| 240 | 18.7 | 1.7 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 41.3 | 46.0 | 50.3 | 4841 | 5770 | 7190 | 1924 | 2852 | 4272 |
| 300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.6 | 44.7 | 49.6 | 53.8 | 6023 | 7041 | 8575 | 2363 | 3381 | 4915 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(3)0.6/ 1kV ,Three Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Three Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Three Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight | |||||||||||
| Cu Conductor | Al Conductor | |||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | |||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
| 1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 10.7 | 13.5 | 15.2 | 130 | 253 | 355 | – | – | – |
| 2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.7 | 14.5 | 16.2 | 173 | 308 | 420 | – | – | – |
| 4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.9 | 15.7 | 17.4 | 227 | 374 | 500 | – | – | – |
| 6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 14.1 | 16.9 | 18.6 | 297 | 458 | 596 | – | – | – |
| 10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.7 | 18.4 | 21.1 | 413 | 591 | 886 | 236 | 414 | 709 |
| 16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.9 | 20.7 | 23.3 | 609 | 811 | 1142 | 314 | 517 | 847 |
| 25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.5 | 24.3 | 27.6 | 903 | 1145 | 1691 | 451 | 694 | 1240 |
| 35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 23.9 | 26.7 | 30.0 | 1187 | 1456 | 2068 | 550 | 814 | 1413 |
| 50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 27.3 | 30.2 | 33.6 | 1563 | 1881 | 2571 | 712 | 1025 | 1701 |
| 70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 1.9 | 26.4 | 29.4 | 33.9 | 2097 | 2403 | 3321 | 849 | 1133 | 1981 |
| 95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 2.0 | 2.2 | 29.8 | 34.6 | 37.6 | 2834 | 3517 | 4238 | 1111 | 1751 | 2420 |
| 120 | 13.3 | 1.2 | 1.3 | 1.4 | 0.5 | 2.5 | 2.0 | 2.0 | 2.3 | 33.2 | 38.2 | 42.4 | 3560 | 4332 | 5510 | 1377 | 2105 | 3226 |
| 150 | 14.5 | 1.4 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 37.9 | 42.5 | 46.9 | 4406 | 5247 | 6577 | 1693 | 2492 | 3762 |
| 185 | 16.4 | 1.6 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.5 | 42.9 | 47.8 | 52.1 | 5491 | 6476 | 7960 | 2109 | 3050 | 4473 |
| 240 | 18.7 | 1.7 | 1.5 | 1.5 | 0.5 | 2.5 | 2.4 | 2.4 | 2.6 | 48.0 | 53.1 | 57.4 | 7144 | 8261 | 9914 | 2707 | 3779 | 5368 |
| 300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 52.5 | 57.5 | 61.8 | 8903 | 10119 | 11914 | 3337 | 4508 | 6235 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(4)0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable | |||||||||||
| Cu Conductor | Al Conductor | ||||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km | ||||
| mm2 | mm | mm | mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
| 1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.5 | 14.3 | 16.0 | 156 | 288 | 398 | – | – | – |
| 2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.7 | 15.4 | 17.2 | 211 | 355 | 478 | – | – | – |
| 4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 13.9 | 16.7 | 19.3 | 279 | 438 | 704 | – | – | – |
| 6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.4 | 18.1 | 20.8 | 370 | 544 | 831 | – | – | – |
| 10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.1 | 19.8 | 22.5 | 527 | 720 | 1036 | 286 | 479 | 795 |
| 16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 19.5 | 22.3 | 25.6 | 778 | 999 | 1509 | 386 | 607 | 1116 |
| 25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 22.6 | 25.4 | 28.7 | 1064 | 1318 | 1890 | 514 | 769 | 1340 |
| 35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.6 | 27.4 | 30.7 | 1340 | 1617 | 2241 | 610 | 883 | 1509 |
| 50 | 8.4 | 1.0 | 25 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 28.4 | 31.4 | 34.7 | 1808 | 2139 | 2870 | 807 | 1134 | 1851 |
| 70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 2.0 | 29.7 | 32.6 | 37.3 | 2446 | 2789 | 3831 | 988 | 1309 | 2280 |
| 95 | 11.7 | 1.1 | 50 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 33.7 | 38.1 | 41.1 | 3313 | 4049 | 4865 | 1307 | 2000 | 2764 |
| 120 | 13.3 | 1.2 | 70 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.3 | 36.3 | 40.9 | 43.9 | 4223 | 5033 | 5913 | 1631 | 2396 | 3223 |
| 150 | 14.5 | 1.4 | 70 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.1 | 2.4 | 41.3 | 46.0 | 50.2 | 5061 | 5993 | 7415 | 1940 | 2826 | 4190 |
| 185 | 16.4 | 1.6 | 95 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 46.6 | 51.4 | 55.6 | 6400 | 7446 | 9076 | 2453 | 3454 | 4983 |
| 240 | 18.7 | 1.7 | 120 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.7 | 52.4 | 57.3 | 61.8 | 8291 | 9484 | 11337 | 3137 | 4284 | 6032 |
| 300 | 20.4 | 1.8 | 150 | 1.5 | 1.5 | 0.5 | 2.5 | 2.7 | 2.6 | 2.8 | 58.0 | 63.0 | 67.1 | 10322 | 11659 | 13632 | 3864 | 5155 | 7058 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(5)0.6/ 1kV ,Four Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Four Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Four Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable | |||||||||||
| Cu Conductor | Al Conductor | |||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km | |||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
| 1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.5 | 14.3 | 16.0 | 156 | 288 | 398 | – | – | – |
| 2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.7 | 15.4 | 17.2 | 211 | 355 | 478 | – | – | – |
| 4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 13.9 | 16.7 | 19.3 | 279 | 438 | 704 | – | – | – |
| 6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.4 | 18.1 | 20.8 | 370 | 544 | 831 | – | – | – |
| 10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.1 | 19.8 | 22.5 | 527 | 720 | 1036 | 286 | 479 | 795 |
| 16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 19.5 | 22.3 | 25.6 | 778 | 999 | 1509 | 386 | 607 | 1116 |
| 25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 23.6 | 26.4 | 29.7 | 1161 | 1427 | 2025 | 559 | 825 | 1423 |
| 35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.8 | 26.3 | 29.1 | 32.6 | 1533 | 1828 | 2519 | 690 | 981 | 1658 |
| 50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 2.0 | 1.7 | 1.6 | 1.9 | 30.1 | 33.0 | 37.3 | 2029 | 2379 | 3410 | 890 | 1235 | 2243 |
| 70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.8 | 1.7 | 2.1 | 30.7 | 35.2 | 38.5 | 2764 | 3443 | 4222 | 1104 | 1739 | 2467 |
| 95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 2.0 | 2.2 | 35.3 | 40.1 | 43.1 | 3746 | 4551 | 5417 | 1454 | 2212 | 3026 |
| 120 | 13.3 | 1.2 | 1.3 | 1.4 | 0.5 | 2.5 | 2.0 | 2.0 | 2.4 | 38.0 | 43.0 | 47.4 | 4697 | 5578 | 6942 | 1790 | 2624 | 3890 |
| 150 | 14.5 | 1.4 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 43.8 | 48.4 | 52.9 | 5816 | 6785 | 8368 | 2203 | 3126 | 4609 |
| 185 | 16.4 | 1.6 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.6 | 48.2 | 53.1 | 57.5 | 7239 | 8342 | 10050 | 2734 | 3791 | 5395 |
| 240 | 18.7 | 1.7 | 1.5 | 1.5 | 0.5 | 2.5 | 2.4 | 2.4 | 2.8 | 53.9 | 59.0 | 63.6 | 9424 | 10676 | 12612 | 3514 | 4718 | 6545 |
| 300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.5 | 3.0 | 61.5 | 66.6 | 71.2 | 11782 | 13205 | 15361 | 4366 | 5742 | 7824 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(6)0.6/ 1kV ,4C+E Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,4C+E Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,4C+E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable | |||||||||||
| Cu Conductor | Al Conductor | ||||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | ||||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
| 1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | – | – | – |
| 2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | – | – | – |
| 4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | – | – | – |
| 6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | – | – | – |
| 10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
| 16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
| 25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.9 | 27.7 | 31.0 | 1337 | 1618 | 2255 | 621 | 901 | 1539 |
| 35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 27.4 | 30.4 | 33.7 | 1709 | 2028 | 2733 | 753 | 1068 | 1759 |
| 50 | 8.4 | 1.0 | 25 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 2.0 | 31.8 | 34.8 | 39.4 | 2313 | 2681 | 3808 | 1009 | 1372 | 2476 |
| 70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 33.2 | 37.6 | 40.7 | 3129 | 3857 | 4653 | 1340 | 2127 | 3000 |
| 95 | 11.7 | 1.1 | 50 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.3 | 37.6 | 42.2 | 45.2 | 4226 | 5064 | 5975 | 1755 | 2658 | 3616 |
| 120 | 13.3 | 1.2 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.1 | 2.4 | 42.3 | 47.0 | 51.1 | 5402 | 6356 | 7786 | 2244 | 3291 | 4882 |
| 150 | 14.5 | 1.4 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 45.7 | 50.4 | 54.7 | 6489 | 7515 | 9080 | 2641 | 3779 | 5532 |
| 185 | 16.4 | 1.6 | 95 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.7 | 50.6 | 55.5 | 59.9 | 8171 | 9323 | 11084 | 3329 | 4625 | 6592 |
| 240 | 18.7 | 1.7 | 120 | 1.6 | 1.5 | 0.5 | 2.5 | 2.7 | 2.6 | 2.9 | 57.0 | 62.2 | 66.3 | 10599 | 11940 | 13888 | 4233 | 5738 | 7873 |
| 300 | 20.4 | 1.8 | 150 | 1.7 | 1.5 | 0.5 | 3.15 | 2.9 | 2.8 | 3.1 | 63.3 | 68.9 | 74.0 | 13205 | 14742 | 17671 | 5200 | 6914 | 10136 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(7)0.6/ 1kV ,Five Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Five Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Five Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable | |||||||||||
| Cu Conductor | Al Conductor | |||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | |||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
| 1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | – | – | – |
| 2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | – | – | – |
| 4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | – | – | – |
| 6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | – | – | – |
| 10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
| 16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
| 25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.8 | 28.6 | 31.9 | 1411 | 1701 | 2366 | 658 | 949 | 1614 |
| 35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 28.9 | 31.9 | 35.2 | 1889 | 2226 | 2954 | 832 | 1163 | 1878 |
| 50 | 8.4 | 1.0 | 1.2 | 1.2 | 0.2 | 2.0 | 1.9 | 1.8 | 2.0 | 33.4 | 36.4 | 40.9 | 2498 | 2883 | 4040 | 1110 | 1489 | 2623 |
| 70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.2 | 36.6 | 41.1 | 44.3 | 3470 | 4271 | 5184 | 1471 | 2296 | 3211 |
| 95 | 11.7 | 1.1 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.3 | 41.3 | 45.9 | 50.1 | 4706 | 5621 | 7080 | 1940 | 2883 | 4353 |
| 120 | 13.3 | 1.2 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.4 | 45.9 | 50.8 | 54.9 | 5910 | 6962 | 8538 | 2426 | 3533 | 5179 |
| 150 | 14.5 | 1.4 | 1.5 | 1.4 | 0.5 | 2.5 | 2.4 | 2.3 | 2.6 | 51.5 | 56.4 | 60.5 | 7299 | 8476 | 10212 | 2948 | 4178 | 5981 |
| 185 | 16.4 | 1.6 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 56.5 | 61.6 | 65.9 | 9097 | 10407 | 12338 | 3685 | 5084 | 7136 |
| 240 | 18.7 | 1.7 | 1.6 | 1.5 | 0.5 | 2.5 | 2.8 | 2.7 | 3.0 | 63.8 | 69.2 | 73.2 | 11840 | 13363 | 15505 | 4704 | 6322 | 8574 |
| 300 | 20.4 | 1.8 | 1.7 | 1.7 | 0.5 | 3.15 | 3.0 | 2.9 | 3.2 | 70.7 | 76.3 | 81.7 | 14765 | 16474 | 19793 | 5783 | 7591 | 11067 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(8)0.6/ 1kV ,3C+2E Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,3C+2E Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,3C+2E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable | |||||||||||
| Cu Conductor | Al Conductor | ||||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | ||||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
| 1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | – | – | – |
| 2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | – | – | – |
| 4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | – | – | – |
| 6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | – | – | – |
| 10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
| 16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
| 25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.0 | 26.8 | 30.1 | 1234 | 1505 | 2116 | 578 | 849 | 1460 |
| 35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.9 | 28.7 | 32.0 | 1506 | 1797 | 2462 | 679 | 966 | 1617 |
| 50 | 8.4 | 1.0 | 25 | 1.2 | 1.0 | 0.2 | 1.6 | 1.8 | 1.7 | 1.9 | 30.4 | 33.3 | 36.6 | 2078 | 2429 | 3200 | 922 | 1269 | 2027 |
| 70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 1.8 | 2.0 | 32.3 | 36.7 | 39.7 | 2817 | 3527 | 4307 | 1201 | 1950 | 2773 |
| 95 | 11.7 | 1.1 | 50 | 1.2 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.2 | 36.6 | 41.0 | 44.0 | 3813 | 4611 | 5487 | 1593 | 2436 | 3348 |
| 120 | 13.3 | 1.2 | 70 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 41.9 | 46.5 | 50.9 | 4967 | 5894 | 7365 | 2044 | 3027 | 4569 |
| 150 | 14.5 | 1.4 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.1 | 2.4 | 44.7 | 49.5 | 53.7 | 5764 | 6773 | 8305 | 2343 | 3418 | 5052 |
| 185 | 16.4 | 1.6 | 95 | 1.5 | 1.4 | 0.5 | 2.5 | 2.4 | 2.3 | 2.6 | 50.0 | 54.9 | 59.0 | 7353 | 8496 | 10216 | 2975 | 4199 | 6006 |
| 240 | 18.7 | 1.7 | 120 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 56.2 | 61.3 | 65.6 | 9461 | 10763 | 12700 | 3778 | 5171 | 7227 |
| 300 | 20.4 | 1.8 | 150 | 1.6 | 1.5 | 0.5 | 2.5 | 2.8 | 2.6 | 3.0 | 62.7 | 67.9 | 72.0 | 11766 | 13238 | 15382 | 4632 | 6193 | 8413 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
We are China Low Voltage Cu/Al Core XLPE Insulated Steel Tape Armored Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Copper Cable Products
3 Core 5 Core 2.5mm 4mm PVC Insulated Solid Flexible 10mm Copper Cable Price
25mm2 Overhead ABC Power Cable with Good Performance
Cu XLPE Insulated Power Feeder PVC Cable 1c 240mm2 1c 185mm2 3c 16mm
XLPE 4 Core Armoured Electric Copper Power Cable
4 Core Low Voltage XLPE 120mm2 Copper Cable
450/750V Cyky 3*1.5 Control Cable
Popular jpcable99 Products
Underground Copper Cable 3X150mm2 12/20 (24) KV XLPE Insualted/ PVC Sheath
High Quality PVC Insulated Unarmored Underground Power Cable
450/750V General Rubber Sheathed Flexible Cables
60% Iacs New Type Copper Clad Steel Wire
Copper Cable XLPE Insulated Power Cable
Popular Steel Tape Armored Products
0.6/1kv 1 Core XLPE Cable, Power Cable
Multi- Core XLPE Insualted Copper Wire Armour 11kv Aluminum Power Cable
8.7 / 15 Kv XLPE Electric Cable Copper Conductor Steel Tape Armored PVC Inner Sheath N2xsry Cable
LV/Flame Redartant/Steel Tape Armored/PVC/XLPE Insulated Electric Power Cable
Popular XLPE Insulated Power Cable Products
Low Voltage XLPE Insulated Steel Wire Armoured Power Cable
6/6 6/10kv Single Copper Core/XLPE Insulated / Power Cable
11kv, 33kv, 66kv Middle Voltage Cable, ASTM Standard
Copper XLPE Cable 0.6/1.0kv 4X35mm2 Cable
6/10kv Mv XLPE Insulated Power Cables Single Core Cables
Tags: Copper Cable, jpcable99, Steel Tape Armored, XLPE Insulated Power Cable