Metal Oxide Lightning Arrester (MOV) /Outdoor Substation

China 
                        Metal Oxide Lightning Arrester (MOV) /Outdoor Substation
                      manufacture and supplier

Metal Oxide Lightning Arrester (MOV) /Outdoor Substation image

Get Latest Price Request a quote

Quick Details

Metal Oxide Lightning Arrester (MOV) /Outdoor Substation

YH10W5-3

ISO9001:2008, Kema Type Test Report

Silicone Rubber, Polymer, Composite

High Voltage, Medium Voltage

1

Metal Oxide Arrester

25 Days

3kv

2.55kv

Metal Oxide Lightning Arrester (MOV)

Grey

10ka

YongDe

Carton for Metal Oxide Lightning Arrester

Zhejiang, China (Mainland)

Product Details

Metal Oxide Lightning Arrester (MOV)/Outdoor Substation

 

0.28kV~756kV Lightning Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.

 

Technical Parameters:

Type YH10W5-3/8.1 4/10μS High current impulse kA 100
Rated voltage———kV 3 Lightning impulse withstand kV 60
MCOV —————-kV 2.55 Power frequency voltage withstand(dry/wet)kV 10
Nominal Current——-kA 10 0.1S TOV————–kV 3.6
Residual voltage of steep impulse—-at 5kA(kV) 9.2 1S TOV—————-kV 3.45
8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) 8.5 10S TOV—————kV 3.3
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) 6.3 1200S TOV————-kV 3
1mA D.C reference voltage (kV) 4.24 Creepage distance —-mm 272
Line discharge level 1 Material employed in series non-linear resistor Zinc Oxide
2mS long duration impulse current A 400 Material of housing silicon rubber

 

Lightning Arresters Drawing:

 

 

Working Condition:

  • Environment temperature: -40–+40 degree
  • altitude:<1000m
  • 48HZ<Rated frequency<62HZ
  • Power frequency voltage should not be more than continuous running voltage
  • Max wind speed should be less than 35m/s
  • Earthquake intensity should be less than 7 degree
  • If used in contamination area, should be noted in advance.

Shipping Information:

Product Name: 3kV,10kA ,Lightning arrester(L,A) Item No: YH10W5-3/8.5
Size: 425mmX145mmX110mm with 3pieces per carton Packing: carton with polyfoam insert parts
MOQ: 1sets Production capacity: 500 sets per day
Payment Terms: T/T 30% before shipment,balance 70% L/C after received B/L Weight: 1.8kg/carton
Trade Terms: FOB,CIF(or we can discuss details) Loading Port: Ningbo/ Shanghai(Or as customer requirement)
Loading Ability:   20’GP 4731sets
  40’GP 9254sets

 

 

Lightning Arresters Production:

 

 

 

 

 

 

We are China Metal Oxide Lightning Arrester (MOV) /Outdoor Substation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular hzyddq Products

Silicon Rubber Insulator Post Insulator

Lighting Arrester/Lightning Rod Lightning Arrestor

New Arrivals Zinc Oxide Varistor

Surge Protection Surge Protector Arrester

High Voltage Substation Lightning Arresters

Innvoation Electrical Station Class Porcelain Surge Arrestors

Popular Lightning Arrester Products

(3-36KV) Housed Metal-Oxide Polymeric Lightning Arrester 11kv Without Gaps

Hy1.5W-0.28/1.3 Zinc-Oxide Arrester

33kv Silicon Type Surge Arrester Cma10W-33-1

Fuse Cutout, Drop out Fuses 72kv 300A

33kv Porcelain Type Surge Arrester Y10c-33

10ka Polymer Housed Lightning Arrester Yh10W-36kv

Popular Lightning Protector Products

Professional Thunder Surge Arresters Manufacturer

Wholesale High Voltage Composite Metal Oxide Surge Arrester 24kv/5ka

Lightning Arrester Rating Metal-Oxide Surge Arresters Kema

High Voltage 35kv Lightning Arrester, Surge Arrester Protector

500kv Outdoor Substation Ceramic Housing Zinc-Oxide Surge Arrester Without Gaps

New Type Composite Housed Gapless 60kv Polymer Lightning Arrester

Popular Surge Protector Products

High Voltage Equipment Metal Silicone Polymer Arrester with Ceramic Insulator

Oxide Gapless 24kv Polymer Type Lightning Arrester for AC System

3kv-36kv Polymer Housed Metal-Oxide Lightning Surge Arrester for Over-Voltage Protection

Outdoor Polymeric Housed Metal Oxide Arresters Surge Protector for 132kv

Wholesale Medium Voltage ZnO Polymeric Surge Arrester 11kv

132kv High Voltage Surge Protector

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION