Metal Oxide Lightning Arrester (MOV) /Outdoor Substation
Metal Oxide Lightning Arrester (MOV) /Outdoor Substation image
Get Latest Price Request a quote
Quick Details
Product Details
Metal Oxide Lightning Arrester (MOV)/Outdoor Substation
0.28kV~756kV Lightning Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | YH10W5-3/8.1 | 4/10μS High current impulse kA | 100 |
| Rated voltage———kV | 3 | Lightning impulse withstand kV | 60 |
| MCOV —————-kV | 2.55 | Power frequency voltage withstand(dry/wet)kV | 10 |
| Nominal Current——-kA | 10 | 0.1S TOV————–kV | 3.6 |
| Residual voltage of steep impulse—-at 5kA(kV) | 9.2 | 1S TOV—————-kV | 3.45 |
| 8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 8.5 | 10S TOV—————kV | 3.3 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 6.3 | 1200S TOV————-kV | 3 |
| 1mA D.C reference voltage (kV) | 4.24 | Creepage distance —-mm | 272 |
| Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
| 2mS long duration impulse current A | 400 | Material of housing | silicon rubber |
Lightning Arresters Drawing:
Working Condition:
- Environment temperature: -40–+40 degree
- altitude:<1000m
- 48HZ<Rated frequency<62HZ
- Power frequency voltage should not be more than continuous running voltage
- Max wind speed should be less than 35m/s
- Earthquake intensity should be less than 7 degree
- If used in contamination area, should be noted in advance.
Shipping Information:
| Product Name: 3kV,10kA ,Lightning arrester(L,A) | Item No: YH10W5-3/8.5 | |
| Size: 425mmX145mmX110mm with 3pieces per carton | Packing: carton with polyfoam insert parts | |
| MOQ: 1sets | Production capacity: 500 sets per day | |
| Payment Terms: T/T 30% before shipment,balance 70% L/C after received B/L | Weight: 1.8kg/carton | |
| Trade Terms: FOB,CIF(or we can discuss details) | Loading Port: Ningbo/ Shanghai(Or as customer requirement) | |
| Loading Ability: | 20’GP | 4731sets |
| 40’GP | 9254sets | |
Lightning Arresters Production:
We are China Metal Oxide Lightning Arrester (MOV) /Outdoor Substation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Outdoor AC System High-Voltage 252kv 200A to 4000A Disconnector Switch
24kv Outdoor Disconnector Switch Isolator
10kv Composite Type Polymeric Metal Oxide Moa Gapless Lightning Arrester
D35 Metal Zinc Oxide Resistance for Surge Arrester
China Qualified Type of Surge Arrester/Low Voltage Surge Protector
Popular Lightning Arrester Products
24kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester
Zinc Oxide Polymeric Surge Arrester
Maintenance Platform (220kV, 110kV)
27kv Silicon Type Surge Arrester Cmr10W-27
Surge Protective Device Lightning Arresters
Popular Lightning Protector Products
9kv 24kv Composite Silicon Rubber ZnO Lightning Arrester 11kv
Distribution Equipment 132kv High Voltage Metal-Oxide Polymeric Ceramic Surge Arrester
21kv Metal Oxide Lightning Protector Arrester for Outdoor
36kv Metal Oxide Lightning Protector Arrester for Outdoor
Electronic Components Low Voltage Surge Arrester Over Current Lightning Arrester
C-Type Gap 10kv Metal Oxide Arrester High Quality Lightning Arrester
Popular Surge Protector Products
18kv Metal Oxide Surge Protector Arrester for Outdoor
Power Transmission Line Equipment Polymer Lightning Surge Arrestor 18kv
Brown Surge Protector Arrester
0.25~765kv Polymer (Porcelain) Housed Lightning Arrester with Kema Type Test
18kv Substation Surge Protector Composite Lightning Arrester for Power Station
Factory Price Current Ceramic ZnO Metal Oxide Gapless Surge Arrester
Tags: hzyddq, Lightning Arrester, Lightning Protector, Surge Protector
