0.6/1 kV ABC Overhead Aerial Bundle Cable Urd Cable Constructions:
Conductor: Round, stranded and compacted aluminum conductor
Insulation: XLPE
0.6/1 kV ABC Overhead Aerial Bundle Cable Urd Cable Standards:
NFC 33-209
0.6/1 kV ABC Overhead Aerial Bundle Cable Urd Cable Application:
The aerial bundled cables designed for supply 0.6/1 kV aerial service for temporary service at construction sites, as a service drop (power pole to service entrance),as a secondary cable (pole to pole) or street lighting.
0.6/1 kV ABC Overhead Aerial Bundle Cable Urd Cable Technical data:
Rated Voltage | 0.6/1kV |
Test Voltage | 4000 V |
Minimum Laying Temperature | -20°C |
Operating Temperature | -40°C~ +90°C |
Maximum Short-circuit Temperature | 250°C |
Maximum Conductor Temperature | 80°C |
Parameter :
Number of cores x nominal cross section | max. conductor- resistance | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight |
---|---|---|---|---|---|
mm^2 | Ohm/km | kN | A | mm | kg/km |
2×10 RM | 3.080 | 1.5 | 38 | 12.8 | 93 |
4×10 RM | 3.080 | 1.5 | 38 | 15.4 | 183 |
2×16 RM | 1.910 | 2.3 | 72 | 14.8 | 129 |
2×16 RN + 2×1.5 RE | 1.910/12.100 | 2.3 | 72 | 14.8 | 176 |
4×16 RM | 1.910 | 2.3 | 72 | 17.8 | 257 |
4×16 RN + 2×1.5 RE | 1.910/12.100 | 2.3 | 72 | 17.8 | 304 |
2×25 RM | 1.200 | 3.8 | 107 | 18.0 | 202 |
2×25 RM + 2×1,5 RE | 1.200/12.100 | 3.8 | 107 | 18.0 | 249 |
4×25 RM | 1.200 | 3.8 | 107 | 21.7 | 404 |
4×25 RM + 2×1,5 RE | 1.200/12.100 | 3.8 | 107 | 21.7 | 451 |
2×35 RM | 0.868 | 5.2 | 132 | 20.8 | 269 |
2×35 RM + 2×1,5 RE | 0.868/12.100 | 5.2 | 132 | 20.8 | 316 |
4×35 RM | 0.868 | 5.2 | 132 | 25.1 | 539 |
4×35 RM + 2×1,5 RE | 0.868/12.100 | 5.2 | 132 | 25.1 | 586 |
2×50 RM | 0.641 | 7.6 | 165 | 23.4 | 352 |
2×50 RM + 2×1,5 RE | 0.641/12.100 | 7.6 | 165 | 23.4 | 399 |
1×54.6 RM + 3×25 RM | 0.630/1.200 | 3.8 | 107 | 21.7 | 507 |
1×54.6 RM + 3×25 RM + 1×16 RM | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 | 24.3 | 573 |
1×54.6 RM + 3×25 RM + 2×16 RM | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 | 29.7 | 639 |
1×54.6 RM + 3×25 RM + 3×16 RM | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 | 31.1 | 705 |
1×54.6 RM + 3×35 RM | 0.630/0.868 | 5.2 | 132 | 25.1 | 615 |
1×54.6 RM + 3×35 RM + 1×16 RM | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 | 28.1 | 680 |
1×54.6 RM + 3×35 RM + 2×16 RM | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 | 34.3 | 748 |
1×54.6 RM + 3×35 RM + 3×16 RM | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 | 35.9 | 814 |
1×54.6 RM + 3×35 RM + 1×25 RM | 0.630/0.868/1.200 | 5.2/3.8 | 132/107 | 28.1 | 714 |
1×54.6 RM + 3×50 RM | 0.630/0.641 | 7.6 | 165 | 28.2 | 741 |
1×54.6 RM + 3×50 RM + 1×16 RM | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 | 31.6 | 806 |
1×54.6 RM + 3×50 RM + 2×16 RM | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 | 38.6 | 875 |
1×54.6 RM + 3×50 RM + 3×16 RM | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 | 40.4 | 940 |
1×54.6 RM + 3×50 RM + 1×25 RM | 0.630/0.641/1.200 | 7.6/3.8 | 165/107 | 31.6 | 841 |
1×54.6 RM + 3×70 RM | 0.630/0.443 | 10.2 | 205 | 33.0 | 950 |
1×54.6 RM + 3×70 RM + 1×16 RM | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 | 37.0 | 1014 |
1×54.6 RM + 3×70 RM + 2×16 RM | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 | 45.2 | 1083 |
1×54.6 RM + 3×70 RM + 3×16 RM | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 | 47.3 | 1148 |
1×54.6 RM + 3×70 RM + 1×25 RM | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 | 37.0 | 1048 |
1×54.6 RM + 3×70 RM + 2×25 RM | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 | 45.2 | 1150 |
1×54.6 RM + 3×70 RM + 3×25 RM | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 | 47.3 | 1250 |
1×54.6 RM + 3×95 RM | 0.630/0.320 | 13.5 | 240 | 37.4 | 1176 |
1×54.6 RM + 3×95 RM + 1×16 RM | 0.630/0.320/1.910 | 13.5/2.3 | 240/72 | 41.9 | 1243 |
We are China NFC 33-209 ABC Aerial Bundled Cables for Overhead Power Lines manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
ABC IEC NFC Standard Distribution and Transmission Cable Aerial Bundle Cable ABC
0.6/1kv ABC Triplex Cable XLPE Insulation Overhead Cable Aluminum Conductor
XLPE Insulated AAC Conductor Aerial Bundled Cable Twisted ABC Cable
ABC Cable Grullo AAC/XLPE +ACSR Aluminium Conductor XLPE Insulation
ABC Cable (Aerial Bundled Conductor)
Electric Transmission ABC Cable Sizes Service Drop Price ABC Cable 3 Phase Wire 25mm 35mm 54.6mm
Popular Aerial Bundled Cables Products
600/1000V ABC Aerial Bundled Cables to BS 7870-5 (AL/XLPE)
Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE)
Low Voltage 4X35mm2 Aluminium Overhead ABC Aerial Bundled Cable
600/1000V ABC Aerial Bundled Cables to NFC 33-209 (AL/XLPE)
Popular jinlingcable Products
Na2xsery 11kv Aluminum Cables Power Transmission Electric Wire Cable
2yslcy Copper Braiding PVC Motor Supply Connection Cable Motor Connecting Cables
Single Core Mineral Insulated Fire Resistant Electric Wire Cable Fire Resistant Cables
H05z1z1 LSZH Flexible Cable Wire
Re-Y (C) Y PE Insulated PVC Sheathed Cwb Twb Shield Computer Power Cable
Popular Overhead Power Lines Products
Overhead Power Transmission Lines Conductors ABC Triplex Bundled Cables
Tags: ABC Cable, Aerial Bundled Cables, jinlingcable, Overhead Power Lines