Basic Info.

Model NO.
Cage-Form WSL series

Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer

Frequency Characteristics
Power Frequency

Brand
Ville

Structure
Three-Column Disconnector

Installation
Indoor High-Voltage

Grounding Mode
Not Grounding

Movement Mode
Vertical Rotary Type

Number of Poles
Three Pole

Grounding
Un Grounded

Series
Three

Run
Vertical Rotation

Switching Mode
Double-Throw Type

Common Model
Vr

Use for
Oil-Immersed Transformer with No-Load Tap Changer

Tank Type
Tank Head Type/Bell Covered Type

Structure Type
Cage Type

Operation Method
on The Tank Head/Driven with Motor

Working Condition
Under Non-Energized Condition

Transport Package
Wooden Case

Specification
IEC CE, ISO

Trademark
VILLE

Origin
Ningbo

HS Code
8504109000

Production Capacity
50000 Sets

Product Description

Off-circuit Cage-form Tap-changer

Product purpose and application scope

WSL Series off-circuit changer is used for oil-immersed transformer with no-load tap changer. It is usually of

cage type structure. The switch transition type is variable with its inner structure. It has linear regulating, single-

bridge stridden over connection, double-bridge stridden over connection, Y– Delta transition, series–parallel

connected transition, positive r reverse regulation ate. This tap changer is classified into two type, one called

tank head type, the other called bell covered type. The operation method can be classified into two type, one is

handled on the tank head or to the grounding, the other is driven with motor. They are used for power

transformer, rectification transformer or furnace transformer in following specification range, rated frequency

with 50Hz or 60Hz, rated voltage with 35kV, 66kV and110kV, rated current with 250A~2000A. This type of tap

changer can only be operated in transformer under non-energized condition.

Company Profile:

Main product line: Tap changer and HV switchgear

Tap changer manufacturing with fullest vertical integration

Tap Changer Products Range On-Load Tap Changer:

* Conventional OLTC for transformer with voltage up to 765kV

*Vacuum OLTC for oil transformer with voltage up to 765kV

*Vacuum OLTC for dry transformer with voltage of 72.5kV

Off-Circuit Tap Changer

* Application for the transformer with voltage up to 765kV

Our Services

1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testing.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months guarantee period normally.

 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China off-Circuit Cage-Form Tap-Changer Circuit Switch Distribution Transformer off Load Tap Changer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular cnville Products

Capacitor Voltage Transformer 110kv 45kv

Jdqxf Series Sf6 Gas-Insulated Stainless Steel Fasteners Voltage Transformer

Dft6-12 Series New Power Supply Equipment Cable Branch Box

High Voltage Shunt Capacitor Unit for AC Power System LV Capacitor Bank

Zw43f-12/630 Outdoor Vacuum Circuit Breaker Vacuum Arc Extinguishing Chamber Air Insulation Vacuum Circuit Breaker 12kv Zw43r-24 Auto Recloser with Controller

Lgbj-110 Type High Insulation Current Transformer/Measuring Equipment

Popular off-Circuit Cage-Form Tap-Changer Circuit Switch Distribution Transformer off Load Tap Changer Products

  • No related articles
  • Popular tap changer Products

    Easy Operation Oil Immersed Transformer Tap Changer Load Break Switch

    Transformer Switch /off-Circuit Tap Changer (Bar Form)

    De-energized Off-load Tap Changer Bar Form Tap Changer Switcher For Transformer

    35kV Oil Immersed Load Break Switch Transformer Tap Changer

    Non-excited Load Linear Type Tap Changer for Distribution and Power Transformers

    Oil Immersed On Load Tap Changer Transformer Load Break Switch

    Popular transformer tap changer Products

    Combined Type Vacuum Innovative on Load Tap Changer for Power Transformer Use Integral Type Glass Fiber Reinforced Epoxy

    Wdl off-Circuit Tap Changers for Transformers/ Transformer Switch

    Vacuum on-Load Tap Changers for Oil Immersed Transformers Switch Cm2 Oltc

    on-Load Tap Changer Transformer Isolation Switch

    off-Circuit Tap Changer for Transformers Distrubution Transformer Switch

    10KV TGV II Dry-Type Vacuum On Load Tap Changer Switcher

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION