Outdoor Rated Voltage 12-36kv porcelain Polymer Lightning Protecting Arrester
Outdoor Rated Voltage 12-36kv porcelain Polymer Lightning Protecting Arrester image
Get Latest Price Request a quote
Quick Details
Product Details
Main features:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | Y10W5-66/176 |
Rated voltage———kV | 66 |
MCOV —————-kV | 52.8 |
Nominal Current——-kA | 10 |
Residual voltage of steep impulse—-at 5kA(kV) | 221 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
1mA D.C reference voltage (kV) | 96 |
Line discharge level | 1 |
2mS long duration impulse current A | 400 |
4/10µS High current impulse kA | 100 |
Lightning impulse withstand kV | 325 |
Power frequency voltage withstand(dry/wet)kV | 140 |
0.1S TOV————–kV | 79.2 |
1S TOV—————-kV | 75.9 |
10S TOV—————kV | 72.6 |
1200S TOV————-kV | 66 |
Creepage distance —-mm | 2500 |
Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Outdoor Rated Voltage 12-36kv porcelain Polymer Lightning Protecting Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Metal Oxide Varistor MOV Block
Post Insulator Porcelain Insulator
Metal Oxide Lightning Arrester (MOV) /Outdoor Substation
Electronic Component Lightning Arrestor MOV
High Quality Chinese Surge Arresters
High Quality Transmission Equipment Surge Over-Voltage Protection
Popular Lightning Arrestor Products
220kv Station Polymer Surge Arrester/Composite Lightning Arrestor
OEM Lighting Arrester Protective Device 36kv Composite Lightning Arrestor
OEM Electrical Power Systems 230kv 10ka Polymeric Housed Lightning Arrester
Hangzhou OEM Lightning Protection Systems 30-220kv ZnO Surge Arrestor
Hangzhou Fuyang 220kv Electrical Supplies Polymeric Gapless Lightning Arrestor
OEM/ODM Power Distribution Equipment 110kv Lightning Arrester with Kema Report
Popular Surge Arrester Products
Factory Porcelain Surge Arrester/Lighting Arrester
Lightning Protection Zinc Oxide Varistors Lightning Arrester
10ka 27-30kv Lightning Arrester Polymeric Metal Oxide Surge Arrester
66kv Ceramic Porcelain Housing Lightning Surge Arrester
Popular Surge Arresters Products
11kv Composite Surge Protector Lightning Arrester
Polymeric Housed Zinc Oxide Lightning Surge Arresters Series Surge Protector
Fuyang Metal Oxide Polymer Surge Arrester with Bracket
Electric Power Line Material Metal Oxide Silicone Surge Arrester 33kv
Kema Tested Polymeric Silicone ZnO Surge Arresters with Hoop
18kv to 66kv 10ka Silicone Housed Composite Metal-Oxide Lightning Arrestor
Tags: hzyddq, Lightning Arrestor, Surge Arrester, Surge Arresters