Power Station Transformer Arrester/ Line Type Lightning Arrestors
Power Station Transformer Arrester/ Line Type Lightning Arrestors image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | YH10W5-15/41.2 | 4/10µS High current impulse kA | 100 |
| Rated voltage———kV | 15 | Lightning impulse withstand kV | 110 |
| MCOV —————-kV | 12.7 | Power frequency voltage withstand(dry/wet)kV | 28 |
| Nominal Current——-kA | 10 | 0.1S TOV————–kV | 18 |
| Residual voltage of steep impulse—-at 5kA(kV) | 44.5 | 1S TOV—————-kV | 17.25 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 41.2 | 10S TOV—————kV | 16.5 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 31.5 | 1200S TOV————-kV | 15 |
| 1mA D.C reference voltage (kV) | 21.2 | Creepage distance —-mm | 500 |
| Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
| 2mS long duration impulse current A | 400 | Material of housing | silicone rubber |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Power Station Transformer Arrester/ Line Type Lightning Arrestors manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed
0.28~500kv Substation Polymer Silicon Rubber Lightning Arrester Price
High Voltage Metal Oxide Varistor Voltage Dependent Resistor SMD Resistor
Kema Tested Polymeric Silicone ZnO Surge Arresters with Hoop
Hv Isolator Disconnector/Isolation Switch
Indoor 24kv Disconnect Switch for Power System
Popular Lightning Arrester Products
High Voltage Line Type ZnO Lightning Arrestors Yh10W-15
Polymer Housed Metal Oxide Surge Arrester 3kv, 5ka
42kv Polymeric Housed Metal Oxide Lightning Arrester
Polymer Housed Metal Oxide Surge Arrester Without Gaps
Popular Surge Arrester Products
Gray Brown Surge Protector Arrester
100kv Porcelain Housing Arrester for Transformer Substation Protection
132kv 10ka Porcelain Housing Lighting Arrester
Middle Voltage 9kv Polymer ZnO Gapless Surge Arrester
Xirui Factory Bulk Hot Sale Mv Ceramic Zinc Oxide Surge Protector Arrester
Popular Surge Arresters Products
Line Lightning Protection 120kv 10ka Silicone Housing Lightning Arrestor
36kv Silicone Rubber Lightning Industry Use Arrester
Kema Tested Polymeric Silicone ZnO Surge Arresters with Hoop
L&R 18kv 10ka Zinc Oxide Varistor Polymer Housed Type Surge Arrester
Lightning Arrestor High Voltage Metal Oxide Station Surge Arrestor
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters
