Power Station Transformer Arrester/ Line Type Lightning Arrestors
Power Station Transformer Arrester/ Line Type Lightning Arrestors image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | YH10W5-15/41.2 | 4/10µS High current impulse kA | 100 |
Rated voltage———kV | 15 | Lightning impulse withstand kV | 110 |
MCOV —————-kV | 12.7 | Power frequency voltage withstand(dry/wet)kV | 28 |
Nominal Current——-kA | 10 | 0.1S TOV————–kV | 18 |
Residual voltage of steep impulse—-at 5kA(kV) | 44.5 | 1S TOV—————-kV | 17.25 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 41.2 | 10S TOV—————kV | 16.5 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 31.5 | 1200S TOV————-kV | 15 |
1mA D.C reference voltage (kV) | 21.2 | Creepage distance —-mm | 500 |
Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
2mS long duration impulse current A | 400 | Material of housing | silicone rubber |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Power Station Transformer Arrester/ Line Type Lightning Arrestors manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Passive Components 3movs Zov ZnO Znr Varistor Prices
500kv Outdoor Substation Ceramic Housing Zinc-Oxide Surge Arrester Without Gaps
Hangzhou Gapless Type Zinc Oxide Lightning Protection Arrester 30kv
Type of Surge Arrester/Low Voltage Lighting Arrester
Kema Tested High Voltage ZnO Surge Arresters with Factory Price
Popular Lightning Arrester Products
33kv High Quality Oxide Zinc Lightning Arrester for Substation
Circular Pipe Insulation Ladder
27kv Metal-Oxide Lightning Arrester for Overvoltage Protection
12kv Surge Arrester with External Gap a Type
Popular Surge Arrester Products
Outdoor Rated Voltage 12-36kv Porcelain Polymer Lightning Protecting Arrester
Porcelain Housed Gapless Surge Arrester/Polymer Housed Station Lightning Arrester
Polymer Housed Surge Arrester With External Gap B
Composite Material Surge Arrester for 24kv/200A
22kv Polymer Housing Surge Arrester
36kv High Voltage Lightning Protector Surge Arrester
Popular Surge Arresters Products
Indonesia Silicone Rubber 66kv Surge Arresters with Electrical Terminals
3kv-36kv Porcelain Housed Surge Arrester
High Voltage Transmission Line Polymer Silicone Rubber Zinc-Oxide Lightning Arrestor
10ka Power Station Type Ceramic ZnO Surge Diverters with Silicone Housed
5kv 10kv 10ka Composite Silicon Rubber Surge Arresters with Kema
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters