Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed
Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | YH5W5-21/56 | 4/10µS High current impulse kA | 65 |
Rated voltage———kV | 21 | Lightning impulse withstand kV | 125 |
MCOV —————-kV | 17 | Power frequency voltage withstand(dry/wet)kV | 50 |
Nominal Current——-kV | 5 | 0.1S TOV————–kV | 25.2 |
Residual voltage of steep impulse—-at 5kA(kV) | 60.5 | 1S TOV—————-kV | 24.15 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 56 | 10S TOV—————kV | 23.1 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 1200S TOV————-kV | 21 |
1mA D.C reference voltage (kV) | 29.7 | Creepage distance —-mm | 662 |
Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
2mS long duration impulse current A | 250 | Material of housing | silicone rubber |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
220kv Substation Porcelain Ceramic Housing Type ZnO Lightning Surge Arrester
0.25~765kv Polymer (Porcelain) Housed Lightning Arrester with Kema Type Test
High Power Metal Oxide Varistor for Lightning Arresters
Transformer Type Composite Metal Oxide Gapless Surge Arrester in China
Electrical Equipment Supplies About Advanced German Tech Polymeric Arrestor
Composite Insulator High Voltage Insulator
Popular Lightning Arrester Products
Electrical 5ka Medium Voltage Silicone Lightning Arrest Ceramic Lighting Arrester
36kv Zinc Oxide Surge Arrester
24kv Polymeric Housed Metal Oxide Lightning Arrester
36kv Metal Oxide Lightning Arrester for Overvoltage Protection
Popular Surge Arrester Products
180-312kv High Voltage Substation Porcelain Composite Polymer Surge Arrester
24kv Station Class Composite ZnO Lightning Arrester Surge Diverter
80ka Surge Arrester Surge Protector Lightning Arrester
Lightning Arrester 10 Ka Type Metal Gapless Oxide 11kv
Electric Porcelain Housed 120kv Surge Arrester Without Gap
Popular Surge Arresters Products
24kv 10ka Polymer Housed Surge Arrester
Nominal Current 5ka Silicone Polymeric Housed Lightening Arrester
24kv 10ka Polymer Housed Surge Arrester
33kv/10ka Polymeric Surge Arrester
Line Lightning Protection 120kv 10ka Silicone Housing Lightning Arrestor
10ka (3-36KV) Polymer Housed Lightning Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters