Medium Voltage Polymeric Housed Lightning Protection Protector
Medium Voltage Polymeric Housed Lightning Protection Protector image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | YH10W5-15/41.2 | 4/10µS High current impulse kA | 100 |
Rated voltage———kV | 15 | Lightning impulse withstand kV | 110 |
MCOV —————-kV | 12.7 | Power frequency voltage withstand(dry/wet)kV | 28 |
Nominal Current——-kA | 10 | 0.1S TOV————–kV | 18 |
Residual voltage of steep impulse—-at 5kA(kV) | 44.5 | 1S TOV—————-kV | 17.25 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 41.2 | 10S TOV—————kV | 16.5 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 31.5 | 1200S TOV————-kV | 15 |
1mA D.C reference voltage (kV) | 21.2 | Creepage distance —-mm | 500 |
Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
2mS long duration impulse current A | 400 | Material of housing | silicone rubber |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Medium Voltage Polymeric Housed Lightning Protection Protector manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Fuyang Electrical Equipment Supplies Moa 132kv Metal Oxide Arrester
Medium Voltage Isolator Switch Fuse Switch
Load Break Disconnect Switch IEC Standard Gw17
Lightning Protection Surge Protection Arrester
Hangzhou Gapless Type Zinc Oxide Lightning Protection Arrester 30kv
Popular Lightning Arrester Products
30kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric
15kv Silicon Type Surge Arrester Cmr10W-15
11kv Silicon Type Surge Arrester Cmr5w-11-1
Polymer Fuse Cutout, Drop out Fuses 30 Kv 100A
36kv Outdoor Polymer & Composite Surge Arrester
Yh10W-36, Sharp Head 10kv 36ka Surge Arrester
Popular Surge Arrester Products
9-12kv Silicon Polymer Surge Arrester, Lightning Arrester
11kv Silicon Surge Arrester Cmr5w-11 33kv Porcelain Lightning Arrester Metal Oxide
Zinc Oxide Lightning Surge Arrester
Hy5ws-12.7/50 Zinc-Oxide Arrester
33kv High Quality Oxide Zinc Surge Arrester for Substation
Popular Surge Arresters Products
Electrical Distribution System Moa/ 10ka Gapless Surge Arrester up to 500kv
Latest Promotion Price 132kv 10ka Power Station Type Surge Arresters
10ka/ 5ka Gapless Lighting Arrest 21kv Moa Surge Diverter
L&R 15kv 10ka Surge Protector Lightning Arrester
Polymeric Lightning Surge Metal-Oxide Arrester
Polymer Housed Metal Oxide Surge Arrester Without Gaps
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters