PVC Insulated Copper Wire Kvv22 Kvvp Control Cable
PVC Insulated Copper Wire Kvv22 Kvvp Control Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application
A. It can be applied to be installation and connection for electrical device, equipment power device, domestic appliance, instrument,lighting circuit, and automation device.
B. The feature of flame retardant cable is not easy to be fired and can control the flame into certain restriction and slow the fire speed after fire. So it can be applied to the occasion with high request of flame retardant.
C. Flame cable can be divided into 4 grade: A,B,C,D and the Grade A is the best flame retardant grade.
D. Beside the cable can transfer power at the normal condition, it can also keep a period of safe operation under fire. It can be applied for the occasion with request of fire resistance.
Pruduct Structure
Reference Data of the Product Structure: IEC 60227
1. 01(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (/km) |
Minumum Insulation Resistance at 70ºC (M·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
1.5 | 1 | 2.82 | 2.6 | 3.2 | 19.70 | 12.1 | 0.011 | 18 |
1.5 | 2 | 3.00 | 2.7 | 3.3 | 20.31 | 12.1 | 0.010 | 18 |
2.5 | 1 | 3.43 | 3.2 | 3.9 | 31.20 | 7.41 | 0.010 | 25 |
2.5 | 2 | 3.69 | 3.3 | 4.0 | 32.82 | 7.41 | 0.009 | 25 |
4 | 1 | 3.90 | 3.6 | 4.4 | 46.08 | 4.61 | 0.0085 | 33 |
4 | 2 | 4.20 | 3.8 | 4.6 | 47.45 | 4.61 | 0.0077 | 33 |
6 | 1 | 4.41 | 4.1 | 5.0 | 65.71 | 3.08 | 0.0070 | 42 |
6 | 2 | 4.77 | 4.3 | 5.2 | 67.19 | 3.08 | 0.0065 | 42 |
10 | 1 | 5.65 | 5.3 | 6.4 | 109.09 | 1.83 | 0.0070 | 58 |
10 | 2 | 6.13 | 5.6 | 6.7 | 113.07 | 1.83 | 0.0065 | 58 |
16 | 2 | 7.18 | 6.4 | 7.8 | 170.90 | 1.15 | 0.0050 | 78 |
25 | 2 | 8.92 | 8.1 | 9.7 | 268.52 | 0.727 | 0.0050 | 105 |
35 | 2 | 10.06 | 9.0 | 10.9 | 362.82 | 0.524 | 0.0043 | 130 |
50 | 2 | 11.81 | 10.6 | 12.8 | 492.15 | 0.387 | 0.0043 | 155 |
70 | 2 | 13.61 | 12.1 | 14.6 | 694.19 | 0.268 | 0.0035 | 200 |
95 | 2 | 15.93 | 14.1 | 17.1 | 959.23 | 0.193 | 0.0035 | 250 |
120 | 2 | 17.54 | 15.6 | 18.8 | 1197.15 | 0.153 | 0.0032 | 290 |
150 | 2 | 19.49 | 17.3 | 20.9 | 1472.95 | 0.124 | 0.0032 | 335 |
185 | 2 | 21.80 | 19.3 | 23.3 | 1846.14 | 0.0991 | 0.0032 | 390 |
240 | 2 | 24.83 | 22.0 | 26.6 | 2416.54 | 0.0754 | 0.0032 | 470 |
300 | 2 | 27.67 | 24.5 | 29.6 | 3023.55 | 0.0601 | 0.0030 | 540 |
400 | 2 | 31.06 | 27.5 | 33.2 | 3851.72 | 0.0470 | 0.0028 | 635 |
2.02(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
1.5 | 5 | 3.00 | 2.8 | 3.4 | 20.30 | 13.3 | 0.010 | 18 |
2.5 | 5 | 3.64 | 3.4 | 4.1 | 31.59 | 7.98 | 0.009 | 25 |
4 | 5 | 4.21 | 3.9 | 4.8 | 47.54 | 4.95 | 0.0070 | 33 |
6 | 5 | 4.81 | 4.4 | 5.3 | 67.42 | 3.3 | 0.0060 | 42 |
10 | 5 | 6.28 | 5.7 | 6.8 | 118.00 | 1.81 | 0.0056 | 58 |
16 | 5 | 7.20 | 6.7 | 8.1 | 169.44 | 1.21 | 0.0046 | 78 |
25 | 5 | 10.10 | 8.4 | 10.2 | 269.71 | 0.78 | 0.0044 | 105 |
35 | 5 | 11.23 | 9.7 | 11.7 | 364.35 | 0.554 | 0.0038 | 130 |
50 | 5 | 13.75 | 11.5 | 13.9 | 522.86 | 0.386 | 0.0037 | 155 |
70 | 5 | 15.40 | 13.2 | 16.0 | 720.89 | 0.272 | 0.0032 | 200 |
95 | 5 | 18.15 | 15.1 | 18.2 | 953.89 | 0.206 | 0.0032 | 250 |
120 | 5 | 19.70 | 16.7 | 20.2 | 1199.28 | 0.161 | 0.0029 | 290 |
150 | 5 | 21.10 | 18.6 | 22.5 | 1485.62 | 0.129 | 0.0029 | 335 |
185 | 5 | 24.03 | 20.6 | 24.9 | 1824.52 | 0.106 | 0.0029 | 390 |
240 | 5 | 26.70 | 23.5 | 28.4 | 2389.69 | 0.0801 | 0.0028 | 470 |
3.05(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
0.5 | 1 | 2.04 | 1.9 | 2.3 | 8.16 | 36.0 | 0.015 | 9 |
0.75 | 1 | 2.21 | 2.1 | 2.5 | 10.71 | 24.5 | 0.012 | 12 |
1 | 1 | 2.37 | 2.2 | 2.7 | 13.48 | 18.1 | 0.011 | 14 |
4.06(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
0.5 | 5 | 2.18 | 2.1 | 2.5 | 8.58 | 39.0 | 0.013 | 9 |
0.75 | 5 | 2.43 | 2.2 | 2.7 | 11.50 | 26.0 | 0.011 | 12 |
1 | 5 | 2.52 | 2.4 | 2.8 | 14.00 | 19.5 | 0.010 | 14 |
5.10(BVV)Cable
Core No.×Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BVV | Minimum | Maximum | BVV | |||||
2×1.5 | 1 | 9.36 | 7.6 | 10.0 | 98.94 | 12.1 | 0.011 | 18 |
2×1.5 | 2 | 9.72 | 7.8 | 10.5 | 103.09 | 12.1 | 0.010 | 18 |
2×2.5 | 1 | 10.56 | 8.6 | 11.5 | 130.99 | 7.41 | 0.010 | 25 |
2×2.5 | 2 | 11.08 | 9.0 | 12.0 | 138.55 | 7.41 | 0.009 | 25 |
2×4 | 1 | 11.50 | 9.6 | 12.5 | 171.31 | 4.61 | 0.0085 | 33 |
2×4 | 2 | 12.10 | 10.0 | 13.0 | 179.24 | 4.61 | 0.0077 | 33 |
2×6 | 1 | 12.52 | 10.5 | 13.5 | 218.41 | 3.08 | 0.0070 | 42 |
2×6 | 2 | 13.24 | 11.0 | 14.0 | 227.77 | 3.08 | 0.0065 | 42 |
2×10 | 1 | 15.64 | 13.0 | 16.5 | 361.55 | 1.83 | 0.0070 | 65 |
2×10 | 2 | 16.70 | 13.5 | 17.5 | 384.71 | 1.83 | 0.0065 | 65 |
2×16 | 2 | 18.80 | 15.5 | 20.0 | 532.01 | 1.15 | 0.0052 | 87 |
2×25 | 2 | 22.64 | 18.5 | 24.0 | 798.61 | 0.727 | 0.0050 | 110 |
2×35 | 2 | 25.72 | 21.0 | 27.5 | 1055.97 | 0.524 | 0.0044 | 140 |
3×1.5 | 1 | 9.8 | 8.0 | 10.5 | 124.61 | 12.1 | 0.011 | 15 |
3×1.5 | 2 | 10.19 | 8.2 | 11.0 | 129.71 | 12.1 | 0.010 | 15 |
3×2.5 | 1 | 11.10 | 9.2 | 12.0 | 168.94 | 7.41 | 0.010 | 21 |
3×2.5 | 2 | 11.66 | 9.4 | 12.5 | 178.67 | 7.41 | 0.009 | 21 |
3×4 | 1 | 12.12 | 10.0 | 13.0 | 228.20 | 4.61 | 0.0085 | 28 |
3×4 | 2 | 12.76 | 10.5 | 13.5 | 238.21 | 4.61 | 0.0077 | 28 |
3×6 | 1 | 13.62 | 11.5 | 14.5 | 307.47 | 3.08 | 0.0070 | 36 |
3×6 | 2 | 14.40 | 12.0 | 15.5 | 319.96 | 3.08 | 0.0065 | 36 |
3×10 | 1 | 16.52 | 14.0 | 17.5 | 476.74 | 1.83 | 0.0070 | 56 |
3×10 | 2 | 17.67 | 14.5 | 19.0 | 507.40 | 1.83 | 0.0065 | 56 |
3×16 | 2 | 20.34 | 16.5 | 21.5 | 726.41 | 1.15 | 0.0052 | 74 |
3×25 | 2 | 24.05 | 20.5 | 26.0 | 1074.22 | 0.727 | 0.0050 | 98 |
3×35 | 2 | 27.31 | 22.0 | 29.0 | 1431.17 | 0.524 | 0.0044 | 120 |
4×1.5 | 1 | 10.51 | 8.6 | 11.5 | 159.43 | 12.1 | 0.011 | 15 |
4×1.5 | 2 | 10.95 | 9.0 | 12.0 | 165.62 | 12.1 | 0.010 | 15 |
4×2.5 | 1 | 11.96 | 10.0 | 13.0 | 216.48 | 7.41 | 0.010 | 21 |
4×2.5 | 2 | 12.59 | 10.0 | 13.5 | 228.55 | 7.41 | 0.009 | 21 |
4×4 | 1 | 13.49 | 11.5 | 14.4 | 296.50 | 4.61 | 0.0085 | 28 |
4×4 | 2 | 14.22 | 12.0 | 15.0 | 309.46 | 4.61 | 0.0077 | 28 |
4×6 | 1 | 15.13 | 12.5 | 16.0 | 398.92 | 3.08 | 0.0070 | 36 |
4×6 | 2 | 15.99 | 13.0 | 17.0 | 414.94 | 3.08 | 0.0065 | 36 |
4×10 | 1 | 17.93 | 15.5 | 19.0 | 594.97 | 1.83 | 0.0070 | 56 |
4×10 | 2 | 19.20 | 16.0 | 20.5 | 633.59 | 1.83 | 0.0065 | 56 |
4×16 | 2 | 22.14 | 18.0 | 35.5 | 916.62 | 1.15 | 0.0052 | 74 |
4×25 | 2 | 27.09 | 22.5 | 28.5 | 1414.08 | 0.727 | 0.0050 | 98 |
4×35 | 2 | 28.84 | 24.5 | 32.0 | 1826.39 | 0.524 | 0.0044 | 120 |
5×1.5 | 1 | 11.31 | 9.4 | 12.0 | 191.08 | 12.1 | 0.011 | 15 |
5×1.5 | 2 | 11.79 | 9.8 | 12.5 | 198.39 | 12.1 | 0.010 | 15 |
5×2.5 | 1 | 12.93 | 11.0 | 14.0 | 260.97 | 7.41 | 0.010 | 21 |
5×2.5 | 2 | 13.63 | 11.0 | 14.5 | 275.46 | 7.41 | 0.009 | 21 |
5×4 | 1 | 15.00 | 12.5 | 16.0 | 370.96 | 4.61 | 0.0085 | 28 |
5×4 | 2 | 15.81 | 13.0 | 17.0 | 387.08 | 4.61 | 0.0077 | 28 |
5×6 | 1 | 16.37 | 13.5 | 17.5 | 482.44 | 3.08 | 0.0070 | 36 |
5×6 | 2 | 17.34 | 14.5 | 18.5 | 501.42 | 3.08 | 0.0065 | 36 |
5×10 | 1 | 19.50 | 17.0 | 21.0 | 725.11 | 1.83 | 0.0070 | 56 |
5×10 | 2 | 20.94 | 17.5 | 22.0 | 771.84 | 1.83 | 0.0065 | 56 |
5×16 | 2 | 24.57 | 20.5 | 26.0 | 1142.09 | 1.15 | 0.0052 | 74 |
5×25 | 2 | 29.61 | 24.5 | 31,5 | 1732.02 | 0.727 | 0.0050 | 98 |
5×35 | 2 | 33.09 | 27.0 | 35.0 | 2272.06 | 0.524 | 0.0044 | 120 |
Notes: Conductor Types–1st type is solid conductor;2nd type is stranded conductor;5th type is stranded soft conductor;
which are suitable for different applications.
We are China PVC Insulated Copper Wire Kvv22 Kvvp Control Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 450/750V Cable Products
Electrical Wire Cable 2.5mm 4mm 10mm 16mm Single Core PVC Insulated Copper Cable Wire
Copper Wire Price List Flexible Flat Copper PVC Insulated Cable Wire Electrical
Shielded Flexible Bare Copper PVC Sheath Power Electrical Multi Cores Electric Cable Rvvp
Popular Cable Products
Medium Voltage XLPE Sheath PVC Insulated Power Cable
Low Voltage 4 Core 150mm2 Copper Cable
0.6/1kv Copper/Aluminum Conductor XLPE Insulated Transmission Line Power Cable
LSZH Cable, XLPE Insulated Swa Armored Power Cable. Electrical Cable,
0.6/1.0kv Alumium Conductor XLPE/PE Insulated 1*70+70mm2 Service Drop Overhead ABC Cable
Standard Power Cable Sizes From Manufacturer with Good Quality
Popular Kvv Wire Products
Kvv/Kvv22/Kvvp/Kvvr/Kvvrp22/Kyjv/Kyjv22 Control Cable and Electrical Wires
Control Cable with Cooper Core and Plastic Insulation
High Quality 2.5mm BV/Bvr Electric Cable
Rated Voltage 450/750 V and Below PVC Insulation and Flexible Cable
Control Cable with PVC Insulation and PVC Sheath Braided Shielding (KVV, KVVP)
Shielded Flexible Bare Copper PVC Sheath Power Electrical Multi Cores Electric Cable Rvvp
Popular wuhancable Products
Overhead XLPE Covered Cable Covered Line Cable
Overhead Conductor Power Transmission Line ACSR
Power/PVC/PE/XLPE/Copper/Insulated/Copper/Rubber Cable
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Woodduck
British Sizes 3242 All Aluminum Alloy Condcutor AAAC Acacia
IEC61089 All Aluminum Alloy Condcutor AAAC 100
Tags: 450/750V Cable, Cable, Kvv Wire, wuhancable