RW11 12kv 100A 200A Outdoor High Voltage Protection Switch Drop-out Fuse Link

China 
                RW11 12kv 100A 200A Outdoor High Voltage Protection Switch Drop-out Fuse Link
              manufacture and supplier

RW11 12kv 100A 200A Outdoor High Voltage Protection Switch Drop-out Fuse Link image

Get Latest Price Request a quote

Basic Info.

Model NO.
RW11

Standard
UL

Rated Voltage
15/24/36kv

Rated Currrent
100-200A

Fuse Current
100-200A

Rated Frequency
50Hz

Use
Transmission Line Branch and Transformer Protecti

Place of Use
Outdoor

Material
Ceramic

Frequency Voltage Wet
30kv

Frequency Voltage to Dry
42kv

The Rated Voltage Lightning Shock
125kv

Crepage Distance Than
32.3mm/Kv

Mechanical Life
500 Times

Transport Package
Carton/ Shipping

Specification
6.58-10.4kg

Trademark
CNKC

Origin
China

Production Capacity
5000PCS/Monthly

Product Description

Product Description
RW11 series drop-out fuses are outdoor high-voltage protection appliances in power transmission and distribution systems. They are installed on the high-voltage side of distribution transformers or on branch lines of distribution lines, and are used for short-circuit and overload protection of transformers and lines, as well as split and combined load currents. The high-voltage ceramic drop-out fuse is composed of a ceramic insulating bracket and a fuse tube. The static contact is installed at both ends of the insulating bracket, and the moving contact is installed at both ends of the fuse tube. The fuse tube is composed of the inner arc suppression tube and the fuse tube. The outer layer is composed of phenolic paper tube or epoxy glass cloth tube. The load drop type fuse enhances the elastic auxiliary contact and arc extinguishing cover to divide and combine the load current.

Model Description

Product technical parameters and installlation size

Bracket installation diagram: 

Product installation effect:

Product features and scope of use

Melt tube structure:
Fuse take made of flberglsaa, damp-proof & corrosion-proof.
Fuse base:
Product base embedded mechanical structure and insulator. Install metal rod mechanism using special binder materials and insulator together , can with stand short-circuit current open the electric power.
Moistureproof fuse has not blister, deformation, open ,large capacity, UV,long life, superior electric properties, dielectric strength and excellent mechanical stiffness and consecrated ability.
The whole organization to neutral, convenient installation, safe and reliable.
1. The ambient temperature is not higher than +40 C, not lower than-40 C
2. The altitude does not exceed 3000m
3.The maximum wind speed does not exceed 35m/s
4. The earthquake intensity does not exceed 8 degrees

Fuse Installation and Operation

1. Installation of drop fuse:
(1) The melt should be tightened during installation (so that the melt is subjected to a tensile force of about 24.5N), otherwise it is easy to cause the contact to overheat.
(2) The fuse installed on the cross arm (frame) should be firm and reliable, and there should be no shaking or shaking.
(3) The melting tube should have a downward inclination angle of 25°±2°, so that the melting tube can quickly fall by its own weight when the melt is blown.
(4) The fuse should be installed on the cross arm (frame) with a vertical distance of not less than 4m from the ground. If it is installed above the distribution transformer, it should maintain a horizontal distance of more than 0.5m from the outer contour boundary of the distribution transformer. A fall of a melting tube caused other accidents.
(5) The length of the fuse tube should be adjusted moderately. It is required that the duckbill tongue can hold more than two-thirds of the length of the contact after closing, so as to avoid the misoperation of self-falling during operation, and the fuse tube should not hit the duckbill. , in order to prevent the melting tube from falling in time after the melt is blown.
(6) The melt used must be a standard product of a regular manufacturer, and has a certain mechanical strength. Generally, the melt is required to withstand a tensile force of more than 147N.
(7) The 10kV drop-out fuse is installed outdoors, and the distance between phases is required to be greater than 70cm.
Second, the operation of the drop fuse:
Under normal circumstances, it is not allowed to operate the drop fuse with load, only it is allowed to operate the no-load equipment (line). However, branch lines of 10kV distribution lines in rural power grids and distribution transformers with rated capacity less than 200kVA are allowed to operate with load according to the following requirements:
(1) The operation shall be carried out by two persons (one to monitor and one to operate), but must wear qualified insulating gloves, insulating boots, and goggles, and operate with qualified insulating rods with matching voltage levels. Operation is prohibited in heavy rain.
(2) During the operation of the gate, it is generally stipulated that the middle phase is pulled first, then the leeward side phase is pulled, and then the windward side phase is pulled. This is because the distribution transformer is changed from three-phase operation to two-phase operation, and the arc spark generated when the intermediate phase is broken is small, which will not cause a short circuit between phases. The second is to break the leeward side phase, because the middle phase has been pulled apart, and the distance between the leeward side phase and the windward side phase has doubled. Even if there is an overvoltage, the possibility of short circuit between phases is very small. When the windward side phase is pulled back, there is only a capacitive current to the ground, and the spark generated is very slight.
(3) When closing, the operation sequence is reversed when closing, first close the windward side phase, then close the leeward side phase, and then close the middle phase.
(4) Operating the melting tube is a frequent item. If you don’t pay attention, it will cause the contact to burn and cause poor contact, overheat the contact, and anneal the spring, which will make the contact worse and form a vicious circle. Therefore, when pulling and closing the fusion tube, use moderate force. After closing, carefully check that the duckbill tongue can be tightly buckled for more than two-thirds of the length of the tongue. You can use the brake lever to hook the upper duckbill and press down a few times. Try pulling again to check if it fits properly. When the switch is closed, it is not in place or not firmly closed, and the static contact pressure on the fuse is insufficient, which can easily cause the contact to burn or the fuse tube to fall by itself.

Product details

Products real shot

A corner of the production workshop

Product packaging

Product application case

 

 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China RW11 12kv 100A 200A Outdoor High Voltage Protection Switch Drop-out Fuse Link manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular cnkcele Products

Dl2 16-400mm² 8.4-17mm Double Hole Type Aluminium Connecting Terminal Cable Lug Electric Power Fitting

Lzzbj4-35kv 200-500A 1600A Indoor Dry Type Pillar Type High Voltage Current Transformer

Vs1-12kv 630-4000A High Voltage Vacuum Circuit Breaker Auto Recloser Vacuum Switch Withdrawable

Jb 16-630mm^2 70-230mm Overhead Cable Parallel Groove Clamp Wire Clamp

Oxy 15-330kv 9-18.2mm Pre-Twisted Single and Double Opgw/ADSS Fiber Optic Cable Suspension Clamps Power Fitting

Ga/Yz/Jh 10kv and Below 10-500mm2 Electric Power Fittings Power Line Live Working Wiring Current Drainage Clamp

Popular Drop out Fuse Products

33kv Drop-out Fuse Cutout Porcelain High Voltage Overhead Line

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series

High Quality 21kv Polymer Drop-out Fuse Cutout Outdoor High Voltage with Fuse Link

12kv Drop out Fuse for Overhead Line

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series

High Voltage Porcelain Cut out Fuse Key

Popular Outdoor Drop out Fuse Products

Yh10wz 66/110kv High Voltage Base Type Zinc Oxide Arrester Power Station Type Lightning Protection

Yh5wz 35kv Zinc Oxide Arrester for High Voltage Power Station

Hrw 12kv 24kv 100A 200A High Voltage Composite Drop-out Type Fuse Cutout Fuse Link

Rn Series 3-40.5kv 50ka 2023 Made in China New Type Indoor Medium and High Voltage Fuses Link

Bdgh Series 7.2-40.5kv 50ka Low Price High Voltage Current Limiting Fuses for Transformer Protection British BS Standards

Xrnt 6kv 12kv 20kv 24kv 35kv 40.5kv 50ka High Voltage Current Limiting Fuses for Protection of Transformers

Popular RW11 12kv 100A 200A Outdoor High Voltage Protection Switch Drop-out Fuse Link Products

  • No related articles
  • Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION