SV Series 35KV-66KV 200A 350A On Load Regulation Tap Changer For Transformers

China 
                 SV Series 35KV-66KV 200A 350A On Load Regulation Tap Changer For Transformers
              manufacture and supplier

SV Series 35KV-66KV 200A 350A On Load Regulation Tap Changer For Transformers image

Get Latest Price Request a quote

  • Overview
  • Product Description

Overview

Basic Info.

Model NO.
On-Load Tap Changer

Certification
ISO9001

Usage
Single-phase Transformer

Frequency Characteristics
Power Frequency

Shape of Core
Ring

Brand
NJREC or OEM

Delivery
25 Days

Materials
Aluminum, Copper, Fiberglass

Color
Green

Connection Method
Trough Type

Label
NJREC or OEM

Rated Current
300A

Rated Voltage
12, 24, 40.5KV

Transport Package
Pallet

Trademark
NJREC

Origin
China

HS Code
853590

Production Capacity
20000pieces/Months

Packaging & Delivery

Package Size
100.00cm * 40.00cm * 10.00cm

Package Gross Weight
100.000kg

Product Description

Product Description
Model Number
F series

Application
Oil Immersed Distribution Transformer & Power Transmission

Place of Origin

CHINA

Type

On load 

Phase Type
Three or single

Production Capacity
20000pieces/months

Rated Current
400A

Rated. Voltage
12KV

Transport Package
Pallet

Certificate
ISO 9001, ISO 14001

On-load tap-changer

 (1) SV series on-load tap-changer

 
(2) F series compound on-load tap-changer
Its rated voltage is 35kV (highest voltage for equipment 40.5 KV) and below, rated current 400A and below. The maximum step voltage for 10kV (highest voltage for equipment12 kV) is with voltage class of 1000v and suitable for oil-immersed on-load voltage regulating power transformers.
(3)On-load tap-changer for capacity and voltage regulation
Its rated voltage is 10kV(highest voltage for equipment 12 kV), applicable to different capacity of oil-immersed transformers ranged from 200(63) kVA to 630 (200) kVA.
(4)Compound vacuum type on-load tap-changer
Its rated voltage is 10kV (highest voltage for equipment 12 kV) and below, rated current is 400A and below, applicable to oilimmersed distribution transformers.
(5)Horizontal vacuum permanent magnet on-load tap-changer
Its rated voltage is 10kV (highest voltage for equipment 12 kV) and below, rated current is 63A and below, applicable to oilimmersed distribution transformers.
(6)Dry-type vacuum on-load tap-changer
Its rated voltage is 10kV (highest voltage for equipment 12 kV) and below, rated current is 165A and below, applicable to dry distribution transformers.

Its rated voltage is 35-66kV(highest voltage for equipment 40.5-72.5 kV), the maximum rated passing current for three- phase tap-changer is 350A or 500A, and they are applied mainly to on-load transformer with rated voltage 1 10kV.

 
 
 

F Series On Load Tap changer

This kind of on-load tap changer has the merits of advanced structure, operating reliably, long useful life and maintenance freely. It is suitable for ol-immersed three-phases transformer with frequency 50Hz, Highest voltage for equipment 40.5KV and below and rated curent under 400A and below.

 

 

 

/* May 10, 2024 16:49:51 */
!function(){function d(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China SV Series 35KV-66KV 200A 350A On Load Regulation Tap Changer For Transformers manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular njrecgroup Products

Oil-immersed load switch is rated voltage 35kv with 2 or 4 positions

NJREC U300B HV Glass Suspension Insulator Ball and Socket Type

Transformer Parts of 417A Tri Clamp Bushing With High Quality

30KV 3150A EN42533 Porcelain Bushing Insulators

C12.5-650 145kv IEC standard solid core post porcelain insulator

1.2kv 1900A spade type 10hole ANSI porcelain transformer bushing

Popular On Load Tap changer Products

China Factory 15 KV Air-Insulated On Load Tap Changer Switcher For Transformers

15 KV Air-Insulated OLTC On Load Electrical Switch For Three-Phases Transformers

Three Phase on Load Tap Changing Oil Immersed Power Transformer Switch

Test Report 15 KV Dry-Type Air-Insulated OLTC On Load Electrical Changer Switch

10KV Dry-Type Vacuum OLTC On Load Tap Changer For Dry Three-Phases Transformers

on-Load Tap Changer Transformer Isolation Switch

Popular SV Series 35KV-66KV 200A 350A On Load Regulation Tap Changer For Transformers Products

  • No related articles
  • Popular tap changer Products

    High Voltage On-Load Transformer Tap Changers and Switcher For Oil-Immersed Transformers

    10KV TGV II Dry-Type Vacuum On Load Tap Changer Switcher

    China Manufacturer Good Quality off circuit  De energized linearity tap changer

    Oil-immersed load switch (LBS) Transformer Tap Changer

    Transformer Accessories on Load Off Load Tap Changer Transformer tap changer

    63A WDP and WSP series De-energized tap-changer or Switch Tray-form For Transformer

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION