SVR 6-35kv 630-20000kVA Outdoor Three-Phase High Voltage Line Feed Automatic Voltage Regulator

China 
                SVR 6-35kv 630-20000kVA Outdoor Three-Phase High Voltage Line Feed Automatic Voltage Regulator
              manufacture and supplier

SVR 6-35kv 630-20000kVA Outdoor Three-Phase High Voltage Line Feed Automatic Voltage Regulator image

Get Latest Price Request a quote

Basic Info.

Model NO.
SVR

Cooling Method
Oil-immersed Type Transformer

Winding Type
Separated Winding Transformer

Certification
CCC

Usage
Pressure Regulator

Frequency Characteristics
High Frequency

Shape of Core
Ring

Brand
Cnkc

Transport Package
Material Flow

Specification
6-35KV 630-20000KVA

Trademark
CNKC

Production Capacity
1000pieces/Year

Packaging & Delivery

Package Size
200.00cm * 100.00cm * 120.00cm

Package Gross Weight
100.000kg

Product Description

Product Description

The SVR line automatic voltage regulator is a device that ensures the stability of the output voltage by tracking the line voltage changes and automatically adjusting the transformation ratio of the device itself. It can automatically adjust the input voltage within the range of ±20%. It is especially suitable for lines with large voltage fluctuations or lines with large voltage drops. Install this feeder voltage regulator in series in the middle of 6kV, 10kV and 35kV lines. At the rear, the line voltage is adjusted within a certain range to ensure the user’s power supply voltage and reduce the line loss of the line. In addition, the SVR feeder automatic voltage regulator is also suitable for substations where the main transformer does not have the ability to regulate voltage. This voltage regulator is installed on the outlet side of the transformer in the substation to ensure the bus voltage on the outlet side. It has a wide range of applications in the national rural power grid, urban power grid, oil field, coal, chemical industry, substation and other fields.

Model Description

Technical parameters and structure dimensions

technical parameters:
1. Rated capacity: 2000KVA, 3150KVA, 4000KVA, 5000KVA 6300kVA, 8000KVA 10000kVA, etc. Special specifications can be customized.
2. Rated voltage: 0.4KV, 6kV, 10kV, 35kV
3. Frequency: 50 Hz
4. Voltage adjustment range: -20%~+20%
5. Gear position: 7-9 gear
6. Connection group: Ya0
7. Transformer oil grade: 25#, 45#
8. Cooling method: ONAN
9. Insulation level: LI60kV/AC25kV(6kV), LI75kV/AC35kV(10kV), LI200kV/AC85kV(35kV)
10. The SVR line automatic voltage regulator adopts a fully sealed corrugated oil tank with oil temperature indication and pressure relief valve; the box has a built-in single-phase voltage to provide sampling signals and working power for the controller;
illustrate:
1. The choice of voltage level should match the line voltage level;
2. The selection of rated capacity is generally 1.1 to 1.2 times the sum of the distribution and variable capacity after the installation point of the regulator.
3. Examples of selection basis for voltage regulation range:
The voltage of the input terminal of the voltage regulator is 9~11kV, and the selection voltage regulation range is: -10%~+10%;
The voltage of the input terminal of the voltage regulator is 8.66~10.66kV, and the selection voltage regulation range is: -5%~+15%;
The voltage of the input terminal of the voltage regulator is 8~10kV, and the selection voltage regulation range is: 0~+20%;
The voltage of the input terminal of the voltage regulator is 7~10kV, and the selection voltage regulation range is: 0~+30%;
Three-phase oil-immersed on-load tap-changer:
1. The resistance of each contact of the switch: related to the number of stages of the on-load tap-changer, <500μΩ
2. Switch electric operation change time: 10s
3. Switching transition resistance switching time: 15~24ms
4. The electrical life of the contacts of the switch under the rated capacity: >50000 times
5. Mechanical life of switch: >500000 times
6. Switch transition mode: single resistance or double resistance
Voltage regulator:
1. Working power supply: AC/DC 110-450V
2. Rated frequency: 50Hz
3. Maximum power consumption: 25W
4. Analog input: 2-way voltage (0,250V)
5. Switch input: 10-way empty contact input
6. Switch output: 2 channels (AC250V/380V l6A)
7. Measurement accuracy: voltage (0.5%)
8. Anti-interference level: meet the requirements of IEC61000-4:1995 level

Product features and scope of use

main feature:
(1) The whole device has large capacity, low loss, small volume, and easy installation and maintenance;
(2) Track the voltage change and automatically adjust the position of the three-phase on-load tap-changer, with reliable action and high voltage adjustment accuracy;
(3) The voltage reference, action delay, allowable range, and number of times can be adjusted as needed, and the parameter setting is flexible and convenient;
(4) Display the SVR on-load tap-changer gear action times and current gear, with the highest and lowest gear indications;
(5) It has the upper and lower limit protection of gears, and the action time limit function, which effectively improves the reliability of the product;
(6) The controller has the functions of over-voltage drop and under-voltage protection. When the line is in over-voltage or under-voltage state, the controller automatically locks; to ensure the safe operation of the on-load tap- changer
(7) The controller adopts industrial-grade control chip, which has high reliability and strong anti-interference ability, and can adapt to harsh outdoor environments;
(8) With RS485 communication interface, the parameters of the controller can be viewed and modified through the wireless communication module.
Environmental conditions:
1. Altitude: ≤2000m
2. Ambient temperature: -25ºC~+45ºC
3. Relative humidity: less than 90%
4. Anti-pollution ability: Class III
5. Installation inclination: < 2%
6. There is no filthy and corrosive medium around the device that seriously affects the insulation performance of the device, and there is no danger of fire and explosion in the workplace, and no violent vibration.
Note: When the working environment exceeds the above conditions, the user needs special instructions when ordering.

Product Standards

1. Production design standards:
JB8749-1998 General technical requirements for voltage regulators
GB1094-2013 Power Transformer
GB/T6451-2008 Three-phase oil-immersed power transformer technical parameters and requirements
GB/T17468-1998 Guidelines for selection of power transformers
GB10230-2007 On-load tap-changer
GB/T1058-1989 Guidelines for the application of on-load tap-changers
DL/T572-2010 Operation Regulations for Power Transformers
2. Acceptance criteria:
The voltage of the SVR line automatic voltage regulator installation point meets the requirements of the national standard GB/T12325-2008 power supply voltage deviation standard: the sum of the absolute value of the positive and negative deviations of the power supply voltage of 35kV and above does not exceed 10% of the rated voltage; 20kV and below three The allowable deviation of the phase power supply voltage is ±7% of the rated voltage; the allowable deviation of the 220V single-phase power supply voltage is +7% and – 10% of the rated voltage.

Product details

Products real shot

A corner of the production workshop

Product packaging

Product application case

 

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China SVR 6-35kv 630-20000kVA Outdoor Three-Phase High Voltage Line Feed Automatic Voltage Regulator manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular cnkcele Products

Hc/CS/Ssa Series 4-20mm 0.3-8kn Optical Fiber Cable Suspension Fix Clamp Power Fitting

Jgh 76-165mm High Voltage Cable Fixing Wire Clamp Single Core Aluminum Alloy Cable Clamp

Hrw/Hrxwo 10-35kv 10A Outdoor Pollution Resistant Type Silicon Rubber High Voltage Current Limiting Fuse

Ttd Series 1kv 77-679A 1.5-400mm² Special Waterproof and Flame-Retardant Insulation Piercing Connector for Street Lamp Distribution System

Sfsz11 110kv 6300-63000kVA Three Phase Air-Cooled Three Winding Oil Immersed Power Transformer

Ybd 6-10kv 30-2000kVA Outdoor Prefabricated Underground Box Type Substation

Popular High Voltage Line Feeder Voltage Regulators Products

Tsja 50-2000kVA 380V 0-650V Three-Phase Oil-Immersed Self-Cooling Induction Voltage Regulator

Ksg 6-10kv 50-1600kVA 400-1200V Common Type Mine Dry-Type Transformer

Kbsg 6-10kv 50-4000kVA Dry-Type Explosion-Proof Transformer for Mine Tunnel

Ksg 2.5-50kVA 24-1440V Low-Voltage Three-Phase Explosion-Proof Dry-Type Transformer for Mine Lighting

Scb 11kv 15kv 33kv 630-3150kVA Three-Phase Dry-Type Transformer

Sg 100-3600kVA 380-3300V Three-Phase Tunnel Special Booster Dry-Type Transformer

Popular SVR 6-35kv 630-20000kVA Outdoor Three-Phase High Voltage Line Feed Automatic Voltage Regulator Products

SVR 6-35kv 630-20000kVA Outdoor Three-Phase High Voltage Line Feed Automatic Voltage Regulator

Popular Three-Phase Oil-Immersed Induction Regulator Products

Tsja 50-2000kVA 380V 0-650V Three-Phase Oil-Immersed Self-Cooling Induction Voltage Regulator

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION