Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp

China 
                Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp
              manufacture and supplier

Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp image

Get Latest Price Request a quote

Basic Info.

Model NO.
TY

Parts
Not Be Dropped

Bolt Quality
1-3

Features
Light Weight

Transport Package
Paper Box

Specification
120*150*60mm

Trademark
CNKC

Origin
China

Production Capacity
10000 Pices/Monthly

Product Description

Product Description

T-clamp refers to the hardware used to connect the conductor with the branch line to transfer electrical load. High voltage transmission line is an important part of power grid, which connects substations and transmits power. In the design of transmission lines, we can see the connection mode of line T-connection. T-connection lines are two lines with different spatial levels connected by short circuit at the intersection of the same voltage level. Substation A supplies power to substations B and C at the same time. The advantages are that investment is reduced and a substation bay is used less. This way of connecting another line from the main line is vividly called “T” connection mode, This outgoing point is called “T contact”.
T-type clamp is mainly used for overhead circuit lines or substations, which leads down current branches on the main bus in a “T” mode. There are two types: bolt type and compression type. For small section conductors, the so-called T-type connection can also be used with parallel groove clamps or clamped elliptical splicing tubes.
TL series single conductor T-clamp is a kind of T-clamp used to connect branch conductor to the trunk conductor, including: T-shaped substrate, with trunk groove in the transverse part, with wire holes in the longitudinal part, metal linings are set on the inner wall of trunk groove and branch hole, and the two metal linings are connected as a whole, and the upper surface of the longitudinal part of the substrate is threaded with branch conductor compression screws; Trunk slot cover is inserted with trunk slot, and its upper surface is screwed with dry conductor compression screw; The T-shaped upper cover is buckled with the T-shaped base. When connecting, only the simple work of fastening screws is needed, which saves time and labor; The branch wire and the dry wire are in close contact with the metal lining through the compression screw, and the contact area is large, so the connection is safe and reliable.
T-type clips are mainly used for overhead circuit lines or substations, and lead down current branches in a “T” shape on the main line of the busbar. There are two types of bolt type and compression type. For small cross-section wires, parallel groove clamps or clamping elliptical joints can also be used for so-called T-type connections.

Technical parameters

Product features

a. The material of the wire clip is exactly the same as the wrapped material (stranded wire), thus ensuring strong corrosion resistance.
b. The special design of the T-clamp avoids the possibility of loss or damage of bolts, nuts, washers and other components during installation or operation, and has high reliability in operation.
c. The installation quality of the wire clamp is less affected by the human factors of the installation workers, the installation quality is consistent, and the installation process will not damage the wire.
d. The installation of the wire clip is simple and quick, without any tools, and one person can quickly complete the installation with bare hands on site.
Grip strength: 25% of the twisted wire is calculated for the breaking force.

Product instructions and common problem solving

Instructions:
a. Follow up the model of the conductor and select the appropriate T-shaped connector strip. T-shaped connectors of different specifications cannot be replaced.
b. T-shaped clamp is a disposable product, which shall not be used repeatedly after bearing full tension.
c. This product is only applicable to the installation of trained technicians.
d. Before the installation of T-shaped clamp, the conductor shall be thoroughly polished to remove the oxide layer, and the surface of the conductor shall be coated with special conductive grease.
e. This product is a precision device. To ensure correct installation, it should be stored in the packaging box to prevent collision or heavy pressure during handling, so as to avoid deformation of the preformed wire.
f. When working on or near live lines, special attention must be paid to prevent electric shock accidents.
g. It is recommended that the electrical performance between the busbar and the downlead be achieved through jumper connection, and the T-shaped connecting strip only bears tension.
FAQ of TY clamp:
The wear of T-shaped clamp is mainly related to its force magnitude and force direction. The pulling force or downward pressure will cause wear, and the force magnitude and force direction are determined by terrain, meteorological conditions and environmental temperature changes. From the design point of view, because the upper layer conductors are mostly tangent towers on both sides, the span is large, and the sag changes greatly under high and low temperature environments, the lower layer conductors are all isolated spans with small span, and the temperature change has little impact on the conductor sag, so it is considered that the length of short T connection when the low temperature sag is small, to ensure that the lower layer conductors will not be pulled up. When the temperature changes at a high temperature, the sag of the upper layer conductor increases and the sag of the lower layer conductor is basically unchanged, the T-connection short circuit wire is bent due to being too long. In the frequent wind action and the annual bending straight alternating change, the main wire and T-connection at the outlet of the T-type clamp will be worn by the clamp and broken.
Solution:
In view of the defects of the above technology, the utility model aims to solve the problem of providing a T-shaped wire clamp with a longitudinal threading seat arranged separately, which can ensure the integrity and use of the main line, and is convenient for installation and construction.
In order to solve the above problems, the utility model provides a T-shaped wire clamp, which comprises a transverse threading seat and a longitudinal threading seat, the transverse threading seat is vertically arranged with the longitudinal threading seat, the transverse threading seat is fixedly connected with the longitudinal threading seat, the transverse threading seat is provided with a transverse channel, the longitudinal threading seat is provided with a longitudinal channel, the transverse threading seat includes a front seat and a rear seat, the front seat is provided with a groove along the transverse direction, and the rear seat is provided with a groove at the corresponding groove position, The groove is aligned with the groove to form a transverse channel. A locking structure is arranged between the front seat and the rear seat, and the longitudinal threading seat is fixedly connected with the rear seat.
The T-shaped clamp with the above structure is used to insert the main line into the transverse channel of the transverse threading seat, and the branch line into the longitudinal channel of the longitudinal threading seat. Since the transverse threading seat is fixedly connected with the longitudinal threading seat, the main line leads electricity into the branch line through the T-shaped clamp, and the branch line is crimped in the longitudinal channel to ensure its effective contact with the longitudinal channel. After the branch line is placed in the groove of the front seat, cover the rear seat. The groove is aligned with the groove to form a transverse channel in the transverse threading seat. The setting of the locking structure makes the front seat and the rear seat relatively fixed, playing the role of fixing the main line. The contact surface generated by the connection between the support on the transverse threading seat and the support on the longitudinal threading seat of the traditional T-shaped clamp is reduced, the stable operation coefficient of the clamp is increased, the integrity of the main line is ensured, and the installation is convenient, the construction is convenient, and the use is good.
As a further improvement of the utility model, the locking structure comprises a screw hole, a screw and a nut. The screw hole is arranged on the front seat and the back seat of the transverse threading seat, the screw is arranged in the screw hole, and the nut is matched with the screw thread.
The locking structure of the above structure is adopted. After the screw is threaded through the screw holes of the front seat and the rear seat, one end collides with the front seat and the other end is matched with the nut thread. After the nut is tightened, it collides with the rear seat to achieve the locking of the front seat and the rear seat. The main line contact is clamped by the bolt, which can effectively protect the twisted carbon fiber composite core conductor as the main line. During installation, the bolt can be firm in the air after the ground branch line is crimped, It is convenient for construction.
Product details

Products real shot

 

A corner of the production workshop

 

Product packagingProduct application case

 

 

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Cable Wire Clamp Products

Jgwd 55-166mm High Voltage Cable Hoop Cable Retaining Clip

PA Series 1kv 4-120mm² Overhead Cable Fixed Insulation Plastic Tensioning Clamp

Ot 10-1000A 5.2-18.2mm Copper Passing Through Connecting Terminal Cable Lugs

Jbt 16-240mm2 Overhead Cable Branch Wire Clamp Copper Parallel Trench Splicing Fitting

Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp

Jbty 10-240mm^2 40*34*45mm Copper Special-Shaped Parallel Groove Clamp Cable Branch Connection Clamp

Popular cnkcele Products

Jy/Ly 35-300mm² 20-36mm Overhead Cable Connection Tube

Bdgh Series 7.2-40.5kv 50ka Low Price High Voltage Current Limiting Fuses for Transformer Protection British BS Standards

Jbly 10-400mm² 43*36*45mm Special-Shaped Parallel Trench Wire Clamp Overhead Cable Wire Clamp

Qh 11-16mm Link Fitting Ball Eyes Electric Power Fittings

Sfsz11 Series 110kv 6300-63000kVA Three Phase Air-Cooled Three Winding Oil Immersed on Load Voltage Regulating Power Transformer

Fbcz 5.5-55kw 380-1140V Mine and Tunnel Flameproof Type Ground Draw out Type Ventilator Fan

Popular Overhead Conductor Clamp Products

Dtf 25-500mm2 11-17mm Water-Proof Connecting Terminal Tinned Copper Cable Lugs

Dl2 16-400mm2 8.4-17mm Double Hole Type Aluminium Connecting Terminal Cable Lug Electric Power Fitting

Tjl Tjt Tjg 16-240mm2 1-10kv Overhead Insulated Cable Branch Connection Wire Clamp

Jbtly 10-400mm^2 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp

Jgwd 55-166mm High Voltage Cable Hoop Cable Retaining Clip

Ny 185-800mm² Tension Clamp for Heat-Resistant Aluminum Alloy Stranded Wire

Popular Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp Products

Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp

Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp

Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION