Get Latest Price Request a quote

Basic Info.

Model NO.
CV2

Max Rated Current
500A

Connection Method
Y, D

Rated Voltage
1.5kv

Applicable Standard
IEC CE, ISO

Transport Package
Wooden Cases

Specification
According to specification

Trademark
VILLE

Origin
Ningbo

HS Code
85

Production Capacity
50000 Sets

Product Description

CV2 Type Vacuum On-Load Tap Changers For Oil Immersed
Transformers 

 

General

CV2 on load tap changer (herein referred as the tap changer) is of selector switch structure, which combines
the functions of diverter and selector. 
The tap changer is mounted to the transformer tank cover by its head.
When the tap changer is used without a change-over selector, the maximum operating positions available is 12,
and it is up to 23 positions if with a change-over selector.
This operating instruction includes the necessary information for the installation and operation of following types
of tap changer (with and without change-over selector).
Three phases tap changer for neutral point: CV2 III-250Y, CV2 III-350Y, CV2 III-500Y.
Three phases tap changer for any connection: CV2 III-250D, CV2 III-350D, CV2 III-500D.
Single phase tap changer: CV2 I-250, CV2 I-350, CV2 I-500.

Model denomination

Example: CV2III-500Y/72.5-10193W
It represents CV2 type, three-phase, 500A max. rated through current, 72.5kV highest equipment voltage, Y-
connection, 19 operating position and three middle-position, with change-over selector.
1 Highest equipment voltage class: 40.5kV, 72.5kV, 126kV, 145kV.
2 Number of operating positions for tap changer:
Without change-over selector, the number of maximum operating position can be up to 10 and12 respectively;
with change-over selector, it can be up to 19,23 respectively.
3 There are two types of change-over selectors, namely reversing regulation represented by W and coarse/fine
regulation represented by G. Mid position no. can be 1or 3. Linear regulation without change-over selector is
represented by 0.4 It can be installed in the transformer by tank type or by bell type.

Rated application conditions and requirement
1 The tap changer is used in oil, the temperature of the oil must not be higher than 100ºC or lower than -25ºC .
2 The environmental air temperature of the tap changer must not be higher than 40ºC or lower than -25ºC .
3 When installing the tap changer on the transformer the perpendicularity with the ground level must not be
bigger than 2%.
4 Any serious dust, explosive or corrosive gases must not be present at the installation site of the OLTC.

Technical Data

Technical parameter of OLTC
1. The contact resistance of different contacts is not greater than 300μΩ.
2. The time of each tap change is about 4.4 sec.
3. Vacuum interrupter of the OLTC at rated capacity could reach 600,000 operations.
4. Mechanical life of the OLTC could reach 1,500,000 operations.
5. The OLTC is maintenance free for 300,000 operations.

Transporting the transformer to the operating site
In case it is necessary to dismount the motor drive from the transformer for transporting reasons,set the motor
drive to the same position as the tap changer. Uncouple the motor drive and drive shaft. For remounting the
motor drive unit, follow the instruction according to section 10.
If the transformer should be stored or transported without oil conservator, a by-pass must be installed between
the interior of the tap changer and the transformer tank to allow for equalizing static pressure caused by
expansion of oil. This by-pass is to be installed between pipe connections E and R of the tap changer head.
The oil level will lower by approx. 5 liters after 2 to 4 weeks storing without oil conservator.
If it become necessary to transport or store the transformer without oil filling, drain the switch oil of the tap
changer completely.
If it tends to be stored for a long time, the heater of motor drive should be powered on.

 

Company Profile

Main product line: Tap changer and HV switchgear

Tap changer manufacturing with fullest vertical integration

Tap Changer Products Range On-Load Tap Changer:

* Conventional OLTC for transformer with voltage up to 765kV

*Vacuum OLTC for oil transformer with voltage up to 765kV

*Vacuum OLTC for dry transformer with voltage of 72.5kV

Off-Circuit Tap Changer

* Application for the transformer with voltage up to 765kV

Our Best Service For You

1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testing.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months guarantee period normally.

FAQ For You

1. Q: What is your delivery time ?
A:  Depend on the type of transformer.
2. Q: What is your payment term?
A:  30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q: What kind of standard you follow?
A:  IEC, ANSI, CSA, GB, etc
4. Q: What kind of supporting documentation you can provide normally
A:  Quotation, outline drawing, manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list, etc
5. Q: What is your normal warranty period?
A:  12 months after transformer operation.
6. Q: Can u do installation and commission in user’s site?
A:  Yes, we can send our installation team to user’s country for service.
7. Q: Do you have any experience in this kind of transformer?
A:  Yes, we can provide reference list for check.

Our advantages:

Quality Assurance

–From the very beginning, VILLE ensures quality in every step to achieve the best quality.

 Experience Sharing

–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.

 Global Service

–Wherever you are, VILLE global network will support and provide you with value.

 Quick Response

–In response to your needs without delay, VILLE  knows the value of your time.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Vacuum on-Load Tap Changers for Oil Immersed Transformer Switch off Circuit Tap Changer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular cnville Products

Lgbj-35W2 Oil-Immersed Structure Current Transformer/Current Transformer

Sz11-16000/35 16mva 35kv Power Transformer with on Load Tap Changer Rectifier Transformers Auto Distribution Transformer

2.5mva Electric Arc Furnace

50kVA 3150V 4X2.5% Three Phase Distribution Transformers with Natural Cooling Hermetically Sealed Transformer

S11-M-100/20 0.1mva 20kv Multi-Function High Quality Distribution Transformer

S11-6300/35 6.3mva S11 Series 35kv Power Transformer with on Load Tap Changer

Popular Tap Changer for Transformer Products

Oltc Online Oil Filter Plant on Load Tap Changer Transformer Switch

off-Circuit Tap Changer for Transformers Distribution Transformer off Load Switch

Vacuum on-Load Tap Changer for Voltage Regulating by Change Tap Position

Transformer Switch High Voltage Under 220kv on Load Tap Changer for Industrial Power Transformer Regulating Voltage Switch

Transformer Switch Conventional Oil Type on-Load Tap Changer CV

Hmk7 Transformer Switch Intelligentized Controller of on-Load Tap-Changer

Popular transformer tap changer Products

Digital Control Motor Drive Unit of on-Load Tap Changer Transformer Switch

Transformer Swich Oltc Multi-Level Coarse Voltage-Regulating on Load Tap Changer for High Voltage Special Transformer

Wdg Type B off-Circuit Tap Changer for Transformers

Vacuum on-Load Tap Changers for Oil Immersed Transformers Switch Cm2 Oltc

CZ Vacuum Type on-Load Tap Changer for Dry Type Transformers

CVT Vacuum on-Load Tap Changer for Dry Type Transformer Power Transformer Switch