Kvv/Kvv22/Kvvp/Kvvr/Kvvrp22/Kyjv/Kyjv22 Control Cable and Electrical Wires
Kvv/Kvv22/Kvvp/Kvvr/Kvvrp22/Kyjv/Kyjv22 Control Cable and Electrical Wires image
Get Latest Price Request a quote
Quick Details
Product Details
Application
A. It can be applied to be installation and connection for electrical device, equipment power device, domestic appliance, instrument,lighting circuit, and automation device.
B. The feature of flame retardant cable is not easy to be fired and can control the flame into certain restriction and slow the fire speed after fire. So it can be applied to the occasion with high request of flame retardant.
C. Flame cable can be divided into 4 grade: A,B,C,D and the Grade A is the best flame retardant grade.
D. Beside the cable can transfer power at the normal condition, it can also keep a period of safe operation under fire. It can be applied for the occasion with request of fire resistance.
Pruduct Structure
Reference Data of the Product Structure: IEC 60227
1. 01(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (/km) |
Minumum Insulation Resistance at 70ºC (M·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
1.5 | 1 | 2.82 | 2.6 | 3.2 | 19.70 | 12.1 | 0.011 | 18 |
1.5 | 2 | 3.00 | 2.7 | 3.3 | 20.31 | 12.1 | 0.010 | 18 |
2.5 | 1 | 3.43 | 3.2 | 3.9 | 31.20 | 7.41 | 0.010 | 25 |
2.5 | 2 | 3.69 | 3.3 | 4.0 | 32.82 | 7.41 | 0.009 | 25 |
4 | 1 | 3.90 | 3.6 | 4.4 | 46.08 | 4.61 | 0.0085 | 33 |
4 | 2 | 4.20 | 3.8 | 4.6 | 47.45 | 4.61 | 0.0077 | 33 |
6 | 1 | 4.41 | 4.1 | 5.0 | 65.71 | 3.08 | 0.0070 | 42 |
6 | 2 | 4.77 | 4.3 | 5.2 | 67.19 | 3.08 | 0.0065 | 42 |
10 | 1 | 5.65 | 5.3 | 6.4 | 109.09 | 1.83 | 0.0070 | 58 |
10 | 2 | 6.13 | 5.6 | 6.7 | 113.07 | 1.83 | 0.0065 | 58 |
16 | 2 | 7.18 | 6.4 | 7.8 | 170.90 | 1.15 | 0.0050 | 78 |
25 | 2 | 8.92 | 8.1 | 9.7 | 268.52 | 0.727 | 0.0050 | 105 |
35 | 2 | 10.06 | 9.0 | 10.9 | 362.82 | 0.524 | 0.0043 | 130 |
50 | 2 | 11.81 | 10.6 | 12.8 | 492.15 | 0.387 | 0.0043 | 155 |
70 | 2 | 13.61 | 12.1 | 14.6 | 694.19 | 0.268 | 0.0035 | 200 |
95 | 2 | 15.93 | 14.1 | 17.1 | 959.23 | 0.193 | 0.0035 | 250 |
120 | 2 | 17.54 | 15.6 | 18.8 | 1197.15 | 0.153 | 0.0032 | 290 |
150 | 2 | 19.49 | 17.3 | 20.9 | 1472.95 | 0.124 | 0.0032 | 335 |
185 | 2 | 21.80 | 19.3 | 23.3 | 1846.14 | 0.0991 | 0.0032 | 390 |
240 | 2 | 24.83 | 22.0 | 26.6 | 2416.54 | 0.0754 | 0.0032 | 470 |
300 | 2 | 27.67 | 24.5 | 29.6 | 3023.55 | 0.0601 | 0.0030 | 540 |
400 | 2 | 31.06 | 27.5 | 33.2 | 3851.72 | 0.0470 | 0.0028 | 635 |
2.02(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
1.5 | 5 | 3.00 | 2.8 | 3.4 | 20.30 | 13.3 | 0.010 | 18 |
2.5 | 5 | 3.64 | 3.4 | 4.1 | 31.59 | 7.98 | 0.009 | 25 |
4 | 5 | 4.21 | 3.9 | 4.8 | 47.54 | 4.95 | 0.0070 | 33 |
6 | 5 | 4.81 | 4.4 | 5.3 | 67.42 | 3.3 | 0.0060 | 42 |
10 | 5 | 6.28 | 5.7 | 6.8 | 118.00 | 1.81 | 0.0056 | 58 |
16 | 5 | 7.20 | 6.7 | 8.1 | 169.44 | 1.21 | 0.0046 | 78 |
25 | 5 | 10.10 | 8.4 | 10.2 | 269.71 | 0.78 | 0.0044 | 105 |
35 | 5 | 11.23 | 9.7 | 11.7 | 364.35 | 0.554 | 0.0038 | 130 |
50 | 5 | 13.75 | 11.5 | 13.9 | 522.86 | 0.386 | 0.0037 | 155 |
70 | 5 | 15.40 | 13.2 | 16.0 | 720.89 | 0.272 | 0.0032 | 200 |
95 | 5 | 18.15 | 15.1 | 18.2 | 953.89 | 0.206 | 0.0032 | 250 |
120 | 5 | 19.70 | 16.7 | 20.2 | 1199.28 | 0.161 | 0.0029 | 290 |
150 | 5 | 21.10 | 18.6 | 22.5 | 1485.62 | 0.129 | 0.0029 | 335 |
185 | 5 | 24.03 | 20.6 | 24.9 | 1824.52 | 0.106 | 0.0029 | 390 |
240 | 5 | 26.70 | 23.5 | 28.4 | 2389.69 | 0.0801 | 0.0028 | 470 |
3.05(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
0.5 | 1 | 2.04 | 1.9 | 2.3 | 8.16 | 36.0 | 0.015 | 9 |
0.75 | 1 | 2.21 | 2.1 | 2.5 | 10.71 | 24.5 | 0.012 | 12 |
1 | 1 | 2.37 | 2.2 | 2.7 | 13.48 | 18.1 | 0.011 | 14 |
4.06(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
0.5 | 5 | 2.18 | 2.1 | 2.5 | 8.58 | 39.0 | 0.013 | 9 |
0.75 | 5 | 2.43 | 2.2 | 2.7 | 11.50 | 26.0 | 0.011 | 12 |
1 | 5 | 2.52 | 2.4 | 2.8 | 14.00 | 19.5 | 0.010 | 14 |
5.10(BVV)Cable
Core No.×Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BVV | Minimum | Maximum | BVV | |||||
2×1.5 | 1 | 9.36 | 7.6 | 10.0 | 98.94 | 12.1 | 0.011 | 18 |
2×1.5 | 2 | 9.72 | 7.8 | 10.5 | 103.09 | 12.1 | 0.010 | 18 |
2×2.5 | 1 | 10.56 | 8.6 | 11.5 | 130.99 | 7.41 | 0.010 | 25 |
2×2.5 | 2 | 11.08 | 9.0 | 12.0 | 138.55 | 7.41 | 0.009 | 25 |
2×4 | 1 | 11.50 | 9.6 | 12.5 | 171.31 | 4.61 | 0.0085 | 33 |
2×4 | 2 | 12.10 | 10.0 | 13.0 | 179.24 | 4.61 | 0.0077 | 33 |
2×6 | 1 | 12.52 | 10.5 | 13.5 | 218.41 | 3.08 | 0.0070 | 42 |
2×6 | 2 | 13.24 | 11.0 | 14.0 | 227.77 | 3.08 | 0.0065 | 42 |
2×10 | 1 | 15.64 | 13.0 | 16.5 | 361.55 | 1.83 | 0.0070 | 65 |
2×10 | 2 | 16.70 | 13.5 | 17.5 | 384.71 | 1.83 | 0.0065 | 65 |
2×16 | 2 | 18.80 | 15.5 | 20.0 | 532.01 | 1.15 | 0.0052 | 87 |
2×25 | 2 | 22.64 | 18.5 | 24.0 | 798.61 | 0.727 | 0.0050 | 110 |
2×35 | 2 | 25.72 | 21.0 | 27.5 | 1055.97 | 0.524 | 0.0044 | 140 |
3×1.5 | 1 | 9.8 | 8.0 | 10.5 | 124.61 | 12.1 | 0.011 | 15 |
3×1.5 | 2 | 10.19 | 8.2 | 11.0 | 129.71 | 12.1 | 0.010 | 15 |
3×2.5 | 1 | 11.10 | 9.2 | 12.0 | 168.94 | 7.41 | 0.010 | 21 |
3×2.5 | 2 | 11.66 | 9.4 | 12.5 | 178.67 | 7.41 | 0.009 | 21 |
3×4 | 1 | 12.12 | 10.0 | 13.0 | 228.20 | 4.61 | 0.0085 | 28 |
3×4 | 2 | 12.76 | 10.5 | 13.5 | 238.21 | 4.61 | 0.0077 | 28 |
3×6 | 1 | 13.62 | 11.5 | 14.5 | 307.47 | 3.08 | 0.0070 | 36 |
3×6 | 2 | 14.40 | 12.0 | 15.5 | 319.96 | 3.08 | 0.0065 | 36 |
3×10 | 1 | 16.52 | 14.0 | 17.5 | 476.74 | 1.83 | 0.0070 | 56 |
3×10 | 2 | 17.67 | 14.5 | 19.0 | 507.40 | 1.83 | 0.0065 | 56 |
3×16 | 2 | 20.34 | 16.5 | 21.5 | 726.41 | 1.15 | 0.0052 | 74 |
3×25 | 2 | 24.05 | 20.5 | 26.0 | 1074.22 | 0.727 | 0.0050 | 98 |
3×35 | 2 | 27.31 | 22.0 | 29.0 | 1431.17 | 0.524 | 0.0044 | 120 |
4×1.5 | 1 | 10.51 | 8.6 | 11.5 | 159.43 | 12.1 | 0.011 | 15 |
4×1.5 | 2 | 10.95 | 9.0 | 12.0 | 165.62 | 12.1 | 0.010 | 15 |
4×2.5 | 1 | 11.96 | 10.0 | 13.0 | 216.48 | 7.41 | 0.010 | 21 |
4×2.5 | 2 | 12.59 | 10.0 | 13.5 | 228.55 | 7.41 | 0.009 | 21 |
4×4 | 1 | 13.49 | 11.5 | 14.4 | 296.50 | 4.61 | 0.0085 | 28 |
4×4 | 2 | 14.22 | 12.0 | 15.0 | 309.46 | 4.61 | 0.0077 | 28 |
4×6 | 1 | 15.13 | 12.5 | 16.0 | 398.92 | 3.08 | 0.0070 | 36 |
4×6 | 2 | 15.99 | 13.0 | 17.0 | 414.94 | 3.08 | 0.0065 | 36 |
4×10 | 1 | 17.93 | 15.5 | 19.0 | 594.97 | 1.83 | 0.0070 | 56 |
4×10 | 2 | 19.20 | 16.0 | 20.5 | 633.59 | 1.83 | 0.0065 | 56 |
4×16 | 2 | 22.14 | 18.0 | 35.5 | 916.62 | 1.15 | 0.0052 | 74 |
4×25 | 2 | 27.09 | 22.5 | 28.5 | 1414.08 | 0.727 | 0.0050 | 98 |
4×35 | 2 | 28.84 | 24.5 | 32.0 | 1826.39 | 0.524 | 0.0044 | 120 |
5×1.5 | 1 | 11.31 | 9.4 | 12.0 | 191.08 | 12.1 | 0.011 | 15 |
5×1.5 | 2 | 11.79 | 9.8 | 12.5 | 198.39 | 12.1 | 0.010 | 15 |
5×2.5 | 1 | 12.93 | 11.0 | 14.0 | 260.97 | 7.41 | 0.010 | 21 |
5×2.5 | 2 | 13.63 | 11.0 | 14.5 | 275.46 | 7.41 | 0.009 | 21 |
5×4 | 1 | 15.00 | 12.5 | 16.0 | 370.96 | 4.61 | 0.0085 | 28 |
5×4 | 2 | 15.81 | 13.0 | 17.0 | 387.08 | 4.61 | 0.0077 | 28 |
5×6 | 1 | 16.37 | 13.5 | 17.5 | 482.44 | 3.08 | 0.0070 | 36 |
5×6 | 2 | 17.34 | 14.5 | 18.5 | 501.42 | 3.08 | 0.0065 | 36 |
5×10 | 1 | 19.50 | 17.0 | 21.0 | 725.11 | 1.83 | 0.0070 | 56 |
5×10 | 2 | 20.94 | 17.5 | 22.0 | 771.84 | 1.83 | 0.0065 | 56 |
5×16 | 2 | 24.57 | 20.5 | 26.0 | 1142.09 | 1.15 | 0.0052 | 74 |
5×25 | 2 | 29.61 | 24.5 | 31,5 | 1732.02 | 0.727 | 0.0050 | 98 |
5×35 | 2 | 33.09 | 27.0 | 35.0 | 2272.06 | 0.524 | 0.0044 | 120 |
Notes: Conductor Types–1st type is solid conductor;2nd type is stranded conductor;5th type is stranded soft conductor;
which are suitable for different applications.
We are China Kvv/Kvv22/Kvvp/Kvvr/Kvvrp22/Kyjv/Kyjv22 Control Cable and Electrical Wires manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 450/750V Cable Products
Flame Retardant 450/750V Copper Core PVC Insulated Electric Wire
2.5mm 4mm 10mm 16mm Single Core PVC Insulated Copper Cable Wire Thw Thhn Electrical Wire Cable
Rvv Cable Copper Core PVC Insulation Flexible Electrical Security Copper Wire Cable
PVC Insulated Copper Conductor Electric Building Wire Cable 1.5mm2
Rated Voltage 450/750 V and Below PVC Insulation and Flexible Cable
Popular Cable Products
4+1 Core XLPE Insulated PVC Sheathed Power Cable
Cable CCA Duplex XLPE Insulated ABC Overhead Cable
450/750V PVC Insulated Cable Communication Used as Power
Popular Kvv Wire Products
Control Cable with PVC Insulation and PVC Sheath Braided Shielding (KVV, KVVP)
Control Cable with Flexible Copper Core and XLPE PVC PE Insulation
Plastic Insulation Control Cable 300/500V
PVC Insulated Shielded Rvvp Control Cable
High Quality 2.5mm BV/Bvr Electric Cable
PVC Insulated Copper Wire Kvv22 Kvvp Control Cable
Popular wuhancable Products
AAAC, ACSR, AAC Aluminum Stranded Conductor ACSR Conductor Sizes
Overhead Bare Electric Cable ACSR Steel Reinforced Aluminum AAC AAAC Conductor
450/750V Copper Core PVC Insulated Electric Wire
Aluminum Clad Steel Wire (acs) to IEC /ASTM /DIN Standard
Aluminium Alloy Conductors Steel Reinforced for Transmission Lien
USA Sizes ASTM B399 All Aluminum Alloy Condcutor AAAC Anaheim
Tags: 450/750V Cable, Cable, Kvv Wire, wuhancable