10mva 110kv Dual-Winding No-Load Tapping Power Transformer Oil Distribution Transformers Price

China 
                10mva 110kv Dual-Winding No-Load Tapping Power Transformer Oil Distribution Transformers Price
              manufacture and supplier

10mva 110kv Dual-Winding No-Load Tapping Power Transformer Oil Distribution Transformers Price image

Get Latest Price Request a quote

Basic Info.

Model NO.
SF10-10000/110

Cooling Method
Oil-immersed Type Transformer

Winding Type
Two-winding Transformer

Certification
ISO9001-2000, UL, ISO9001, CCC

Usage
Combined Transformer, Power Transformer, Three Phase

Frequency Characteristics
High Frequency

Shape of Core
Ring

Brand
Ville

Test Certification
CQC Transformer Test

Voltage Range Hv
110/115/121/+-2X2.5%

LV
6.3/6.6/10.5/11/

Rated Power Definitionwer
10000kVA

Tap Changer
Mr or Hm China

Vector Group
Yn, D11

Transport Package
Wooden Cases and Main Body Nude Packing

Specification
IEC Standard

Trademark
VILLE

Origin
China

HS Code
8504231200

Production Capacity
1set/6monthes

Product Description

10000kVA 110KV S10 Dual-winding Power Transformer with on load tap
changer

Technical parameters:

Voltage combination and tapping rangeHV:110kv 115kv 121kv+-2×2.5%
LV: 6.3 6.6 10.5 11
Connection group:yn,d11
Winding combination:H-L
No-load current(%):0.64
No-load loss(kW):11.2
On-load loss(kW ):48.5
Lmpedance(%):10.5
Weight of active part(kg) Around:17.5ton
Transport weight(kg):Around22ton(filling with nitrogen)
Transport dimension (L W H mm):4380x3080x4886
Capacity:10000kva

Structure characteristic:
1,Iron core
1. 1The iron core adopts cold-rolled crystal-oriented silicon steel plate 30Z140 with high quality, low-loss, and
no time effect, sheared by Geroge line and with no burr. 1.2 Iron core adopts pulling board structure, the upper
and down yoke is clamped by board, to form the frame structure. The iron core adopts advanced lamination
process, which effectively controls the no-load loss and electro-magnetic noise.

2 Winding
2.1 Winding adopts mature structure, which ensure the reliability of transformer operation.
2.2 The insulation power field intensity between turns shall be controlled no greater than 1.6kV/mm.

3,Body
3.1 Body adopts mature insulation structure, and strictly guarantee the main axial insulation margin.
3.2 Body mostly adopt multi-coil whole assembly, processed in constant voltage and evaporation, which made
coil shrink evenly and with less rebounce, and enhance the electric strength and mechanical strength.

3.3 Adopt laminating wood board or thermal shaped insulation cardboard. Pressed tightly with pin, which ensure
the winding is constantly pressed tightly. 

4,leading wire
4.1 The layout of all leading wire is reasonable, which guarantees the enough electric distance and mechanical
strenth. 

4.2 All leading wire is cirlulized ,which guarantee the reliable wild or prize connection. 

5,Oil tank
5.1 Oil tank adopts structure of flat top, bell jar type, which add the mechanical strength of oil tank and also
make the appearance beautiful and graceful, site installation tend to be more convenient.

5.2 Pipeline with gas relay such as the oil tube and bushing hoist support on top of oil tank is with hoist
gradient, to facilitate the gas in transformer flow to gas relay.

5.3 Vacuum oiling is adopted, there is no leakage and permanent distortion in the following test. vacuum-
pumping :759mmHg load voltage test: bear 2 times the oil pressure of oil conservator oil surface for 24 hours.

5.4 The structure of transformer is convenient for disassembly and change of bushing and porcelain element.
5.5 The oil drip valve is set on the bottom of oil tank, sampling valve is set in the middle.
5.6 collective gas connecting tube is fixed on the bushing hoist support.
5.7 Transformer is of full-sealed structure, the upper and down oil tanks are required to welded fully. 

6,Oil conservation tank 
6.1 Adopt capsule type, finger type oil level indicator oil conservation tank. 
6.2 The structure is convenient for internal cleaning, the capacity can ensure no oil overflow in 40 ambient
temperature with full load, and oil shall be seen from oil level indicator before put into operation in -25.

6.3 Oil conservation tank is equipped with oil-sealed moisture absorber. 

7,Safety protection device:
7.1 Gas relay is fixed in transformer, the standard complies with ZBK41004-89Gas relay.
7.2 There is enough and reliable pressure release device, and matched with oil spray pipe, the direction of oil
spraying is downward. 

8,Oil temperature measuring device:
8.1 There is pipe support of mercury thermometer, which is  set on the top of oil tank.
8.2 There is temperature controller,  the accuracy of thermometer complies with the related standard. Quantity
and technical requirement shall as per tender document. 

9,Each component  of transformer shall be prefabricated once in manufacture factory, marked, to ensure the
smooth procedure of site assembly. Before Ex-factory, inner core shall be check, and clean the fifth in
transformer.

Outline drawing:

Reference:

Workshop

Packing and Shipping

The accessories packed in plywood cases,the main body in nude.


Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE  knows the value of your time.

Our Best Service For You

1. Pre sale service
A. Make technical solution
B. Send quotation, technical data sheet and drawing
C. Prepare power transmission plan, testing plan,and shipment plan
2. In sale service
A. Supervise the manufacturing schedule totally in accordance with the plan
B. Send photos to customer during every manufacturing process(hold point)
C. Inform the customer one week before testinng.
3. After sale service
A. Installation and commissioning, training the workers
B. Quick response within 12 hours any time
C. Provide 12 months gurantee period normally.

FAQ For You

1.Q: What is your delivery time ?
A: Depend on the type of transformer.
2.Q: What is your payment term?
A: 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3.Q: What kind of starndard you follow?
A: IEC, ANSI, CSA, GB, etc
4.Q: What kind of supporting documentation you can provide normally
A: Quotation,outline drawing,manufacturing plan, quality control plan
Testing plan, financial report, type test report(KEMA, CESI),reference list,etc
5.Q: What is your normal wanrranty period?
A: 12 months after transformer operation.
6.Q: Can u do installation and commissioningin user’s site?
A: Yes, we can send our installation team to user’s country for service.
7.Q: Do you have any experience in this kind of transformer?
A: Yes, we can provide reference list for check.
8.Q: Are you manufacturer or trading company?
A: Manufacturer and Trading company.

Our sales team:


Order Instructions

When you choose our company product, please offer following data:

Transformer model:                     

Rated capacity:                     kVA

Phase       :    Three-phase

  • Single-phase

Frequency   :     50HZ

  •  60HZ

Rated voltage ( H.V. / L.V. ):                

Tapping range: ±       ×       %

Insulation level: LI       AC       / LI       AC        kv

Veotor group:  Dyn11

             Yyno

             Other

Short-circuit Impedance:        %

Cooling method:  ONAN

                ONAF

Tapping method:  OLTC

                OCTC

                Other

Other requirement:                                            

Notes:

  1. We also can design special products according to customer’s particular requirements.
  2. The final dimension is subject to outline drawing.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China 10mva 110kv Dual-Winding No-Load Tapping Power Transformer Oil Distribution Transformers Price manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 10mva 110kv Dual-Winding No-Load Tapping Power Transformer Oil Distribution Transformers Price Products

  • No related articles
  • Popular cnville Products

    Sfsz10-40000/110 40mva 110kv Three-Winding Load Tapping Power Transformer

    Corundum Furnace for Power Plant, Heavy Duty Industry

    S10 31.5/220kv 31.5mva 220kv Double-Winding off-Circuit-Tap-Changer Power Transformer

    Shzv Vacuum on-Load Tap Changer for Oil Immersed Transformers Switch

    Metal Bellows for Transformer Transformer Parts

    Portable Overhead Line Earthing Set Earth Set, Copper Cable

    Popular DC Transformer Power Products

  • No related articles
  • Popular Power Transformer Products

    11kv 33kv Type Sc (B) Dry-Type Transformer Dimensions with Protection Enclosure

    11kv 12kv 15kv 30~1000kVA Distribution Transformers

    11kv Sz11 Type on-Load Tap Changing Transformer

    110kv and Above Rectifier Special Transformer

    Oil Immersed Distribution Transformer 6.6kv

    OEM Three Phase Overhead Pole Mounted Distribution Transformer

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION