S/N | Description | Units | Schedule A | Schedule B | |
1 | Current ratings | A | 5 | ||
2 | Frequency | Hz | 50 | ||
3 | Rated Speed ratio | Type K as per IEC 60282 -2 |
|||
4 | Class of fuse link | Class B as per IEC 60282-2 |
|||
5 | Fuse element | Tin or Silver | |||
6 | Following Routine test results shall be provided on delivery of fuse links | Yes/No |
a) a static strength test; and | Yes | |
b) a resistance test, with the fuse-link under strain. |
Yes |
||||
7 | The following tests shall be performed on one fuse-link per batch and test results provided on delivery of fuse links: |
Yes/No |
a)confirmation of the time/current characteristics; and |
Yes |
|
b) a dynamic strength test. | Yes | ||||
8 | Drawing showing construction and dimensions as per figure 1 below to be provided with bid |
Yes/No | Yes | ||
9 | Previous type tests reports/certificate to be provided on bid. |
Yes/No |
Yes |
||
10 | Altitude above sea level | m | 1400 | ||
11 | Ambient operating | oC | -1 to 40 |
Performance Characteristic | |
Applied standard | IEEE C37.42-2009 |
Catalog number | |
Nominal system voltage kV | 22 |
Rated Frequency Hz | 50 |
Rated m aximum(design) voltage | 27 |
Rated Continuous current A-RMS | 100 |
Rated Interrupting current asymmetrical/symmetrical A-RMS | 12000/8000 |
BIL 1.2×50 µs kV-peak | 125 |
Minimum critical impulse flashover voltage(CFO)KV peak | 140 |
Dry withstand voltage kV-RMS | 42 |
Wet withstand voltage kV-RMS | 36 |
Creepage distance to group Min.mm | 320 |
Minimum creepage factor of insulator (Creepage Distance/arcing distance) | 2 |
Performance Characteristic | |
Applied standard | IEC60282-2 |
Catalog number | |
Nominal system voltage kV | 11 |
Rated Frequency Hz | 50 |
Rated m aximum(design) voltage | 12 |
Rated Continuous current A-RMS | 100 |
Rated Interrupting current asymmetrical/symmetrical A-RMS | 12000/8000 |
BIL 1.2×50 µs kV-peak | 125 |
Minimum critical impulse flashover voltage(CFO)KV peak | 140 |
Dry withstand voltage kV-RMS | 42 |
Wet withstand voltage kV-RMS | 36 |
Creepage distance to group Min.mm | 372 |
Minimum creepage factor of insulator (Creepage Distance/arcing distance) | N/A |
Performance Characteristic | |
Applied standard | IEEE C37.42-2009 |
Catalog number | |
Nominal system voltage kV | 33 |
Rated Frequency Hz | 50 |
Rated m aximum(design) voltage | 38 |
Rated Continuous current A-RMS | 100 |
Rated Interrupting current asymmetrical/symmetrical A-RMS | 8000/5000 |
BIL 1.2×50 µs kV-peak | 150 |
Minimum critical impulse flashover voltage(CFO)KV peak | 165 |
Dry withstand voltage kV-RMS | 70 |
Wet withstand voltage kV-RMS | 60 |
Creepage distance to group Min.mm | 650 |
Minimum creepage factor of insulator (Creepage Distance/arcing distance) | 2.3 |
DIMENSION(mm) | |||||
RATED CURRENT (A) |
A | B | C | D | L MN |
1 to 25 | 12.5+0.2 | 19.0+0.2 | 6.5 | 2.0 | 533,600,787 |
30 to 40 | 12.5+0.2 | 19.0+0.2 | 8.0 | 3.0 | 533,600,787 |
50 to 100 | 19.0+0.3 | not applicable | 9.0 | 5.0 | 533,600,787 |
140 to 200 | 19.0+0.3 | not applicable | 13.0 | 7.0 | 533,600,787 |
Recommended for You
Not exactly what you want?
Post Sourcing Request
Hot Searches
Electric Fuse
Voltage Fuse
High Voltage Fuse
Protection Fuse
Fuse Box
We are China 1kv Insulation Piercing Grounding Connectors manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 82mm 92mm Products
Lov Voltage High Quality 415V/500V Slotted Wedge HRC High Breaking Capacity Jpu BS88 Fuse Link
Fuseholder 100 AMPS, 15kv, 110kv, Bil, Chance Cat
Overhead Service Mv Pole Mounted Fuse Cut out and Carrier 400A
High Quality 415V 80A Slotted Wedge HRC High Breaking Capacity Jpu BS88 Fuse Link
Overhead Service LV Pole Mounted Fuse Cut out and Carrier 415V
Low Voltage 415V/500V Slotted Wedge HRC High Breaking Capacity Fuse BS88 82mm Jpu
Popular HRC Fuse Link Products
Overhead Service Mv Pole Mounted Fuse Cut out and Carrier 400A
New HRC Jpu Type 415V 100A Fuses Base /Cutout Fuse
Overhead Service Pole Mounted Fuse Cut out and Carrier 415V 100A
No-Filling Sealed Pipe-Type Fuse
J Type Fuses Holder Base, J Services Cutout Fuse Box House Holder Base
Overhead Service LV Pole Mounted Fuse Cut out and Carrier 415V
Popular jgtrade1 Products
Fuse Cutout, Drop out Fuses 21kv 300A
Hy10W-21, 21kv 10ka Surge Arrester
Splicing Sleeves for Aluminium Conductor Compression with Pliers
Fuse Cutout, Drop out Fuses 11kv 100A
15kv 200A Electrical Expulsion Porcelain Drop out Fuse Cutout Price
Popular Low Voltage Fuse Products
J Type Fuses Holder Base, J Services Cutout Fuse Box House Holder Base
High Quality 415V 80A Slotted Wedge HRC High Breaking Capacity Jpu BS88 Fuse Link
Overhead Service LV Pole Mounted Fuse Cut out and Carrier 415V
High Quality 415V/80A Slotted Wedge HRC High Breaking Capacity Jpu BS88 Fuse Link Jpu
J Type Fuse Holder 82mm 92mm Jpu 630A 500A 400A 600V 415V Wedge J Type Fuse
Overhead Service Pole Mounted Fuse Cut out and Carrier 100A
Tags: 82mm 92mm, HRC Fuse Link, jgtrade1, Low Voltage Fuse