250kv Substation Type Line Discharge Level 3 Ceramic Lightning Arrester
250kv Substation Type Line Discharge Level 3 Ceramic Lightning Arrester image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | Y10W5-108/281 |
Rated Voltage———kV | 108 |
MCOV —————-kV | 86 |
Nominal Current——-kA | 10 |
Residual voltage of steep impulse—-at 5kA(kV) | 325 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 274 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 215 |
1mA D.C reference voltage (kV) | 157 |
Line discharge level | 3 |
2mS long duration impulse current A | 850 |
4/10µS High current impulse kA | 100 |
Lightning impulse withstand kV | 550 |
Power frequency voltage withstand(dry/wet)kV | 230 |
0.1S TOV————–kV | 129.6 |
1S TOV—————-kV | 124.2 |
10S TOV—————kV | 118.8 |
1200S TOV————-kV | 108 |
Creepage distance —-mm | 3906 |
Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China 250kv Substation Type Line Discharge Level 3 Ceramic Lightning Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
500kv Substation Type Polymer Housed Lightning Arrester Price 33kv
Power Transmission Line Equipment 6 Kv Surge Arrestors
Lighting Surge Arrester Lightning Protector
Building Composite Housing Gapless Arrester Lightning in The Phillippines
Fuyang Yongde Surge Arrestor Component ZnO Varistor
Popular Lightning Arrester Products
24kv Porcelain Type Surge Arrester Y5c-24
Surge Arrester Lower Voltage Arrester Lightning
35kv Silicon Type Surge Arrester Cma5wc-51/134
Custom Available Power Station Equipment 110kv Porcelain Ceramic Arrester
Polymer Housed Metal Oxide Lightning Arrester Without Gaps
30kv Metal Oxide Lightning Arrester for Overvoltage Protection
Popular Surge Arrester Products
36kv High Quality Oxide Zinc Surge Arrester for Substation
9kv Metal-Oxide Surge Arrester for Overvoltage Protection
MOV Metal-Oxide Lightning Protector/ Surge Arrester (YH5W)
Hy10W-21, 21kv 10ka Surge Arrester
Yh10W-66, 66kv 10ka Surge Arrester
Popular Surge Arresters Products
220KV Porcelain Housed Station Surge Arrester
(3-36KV) Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
10ka (3-36KV) Polymer Housed Lightning Arrester
High Voltage Electric Silicone Porcelain Surge Arrester 36kv to 110kv
11kv Composite Surge Protector Lightning Arrester
Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters