40.5kv Vacuum Circuit Breaker with Current Transformer
40.5kv Vacuum Circuit Breaker with Current Transformer image
Get Latest Price Request a quote
Basic Info.
Product Description
General:
ZW30-40.5/2000-31.5 outdoor HV vacuum circuit breaker (hereinafter referred to as ZW30-40.5) can be used
in the power system with rated voltage 40.5KV, rated current 2000A and three – phase AC 50HZ to protect the
equipment in the industrial and mineral enterprises, power plants and substations, which can be used as a
connecting circuit breaker in the workplaces of frequent operation.
This product complies with the standards of the GB1984-89 AC HV Circuit Breaker, IEC56 HV AC Circuit
Breaker and JB3385-1996 3.6-40.5KV Indoor AC HV Vacuum Circuit Breakers.
Features:
A, This product is for outdoor high voltage vacuum circuit breaker, the overall structure of the ceramic column,
a vacuum interrupter in the porcelain, the circuit breaker under the outlet end of the use of the slider-type
contact, the product has a smaller loop resistance and good oriented, the next set of ceramic pillar, to ensure
live parts of the insulation, ceramic kit has absolutely bar, mounted on a common three-phase bottom box on
the upper and lower porcelain comprising a charge 0.02Mpa (20 c) the provisions of gas.
B, the product with 1 to 6 can be independent of the current transformers, transformers can be installed into the
circuit breaker or the outlet end of the line side, or both ends installed. Independent of the current transformer
under its accuracy at any level can meet user requirements, and can be done once or twice without disturbing
each other.
C, with a special trip the circuit breaker signs device that can be read at any time convenient to the vacuum
interrupter trip and overtravel.
D, the circuit breaker oil with excellent cushioning buffer and sub-gate stopper.
E, the circuit breaker is equipped with CT17-IVB-type spring operating mechanism.
| NO | Name | Unit | Data | ||||
| 1 | Rated voltage | KV | 40.5 | ||||
| 2 | Rated insulating level | Rated 1min power frequency withstand voltage | Dry test (fracture,phase-to-phase,phase-to-earth) | 95* | |||
| Wet test (to earth, external insulation) | 80* | ||||||
| Lightning impulse withstand voltage (crest) | 185* | ||||||
| 3 | Rated current | A | 2000 | ||||
| 4 | Rated short-circuit breaking current | KA | 31.5 | ||||
| 5 | Rated short-circuit making current( crest) | 80 | |||||
| 6 | Rated operative sequence | 0-0.3sCO**-180s-CO** | |||||
| 7 | Rated out-of-phase breaking current | KA | 8 | ||||
| 8 | The rated single condenser group breaking current | A | 630 | ||||
| 9 | Rated short-circuit lasting time | S | 4 | ||||
| 10 | Rated short-circuit breaking times | Times | 20 | ||||
| 11 | Arcing time | Ms | <20 | ||||
| 12 | Fully breaking time | Ms | <=85 | ||||
| 13 | Mechanical endurance( CO) | Times | 10000 | ||||
| 14 | Rated charge pressure | Apply TD-40.5W/2000-31.5( K) Vacuum arc-chute filled with SF6 | Mpa | 0.02( 20ºC) | |||
| Apply TD-40.5W/2000-31.5( K) Vacuum arc-chute filled with dry air and pure nitrogen | |||||||
| 15 | Annual leakage rate | % | <=1 | ||||
| 16 | The degree of vacuum arc-chute |
Arc-chute newly produced | Pa | <=1.33X10 -3 | |||
| Storage period for 20 years | < 6.6X10 -2 | ||||||
Our Services
| 1. | Pre sale service |
| a. | make technical solution |
| b. | send quotation, technical data sheet and drawing |
| c. | prepare power transmission plan, testing plan,and shipment plan |
| 2. | In sale service |
| a. | supervise the manufacturing schedule totally in accordance with the plan |
| b. | send photos to customer during every manufacturing process(hold point) |
| c. | inform the customer one week before testinng. |
| 3. | After sale service |
| a. | installation and commissioning, training the workers |
| b. | quick response within 12 hours any time |
| c. | provide 12 months gurantee period normally. |
FAQ
| 1. Q: | What is your delivery time ? |
| A: | Depend on the type of transformer. |
| 2. Q: | What is your payment term? |
| A: | 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
| 3. Q: | What kind of starndard you follow? |
| A: | IEC, ANSI, CSA, GB, etc |
| 4. Q: | What kind of supporting documentation you can provide normally |
| A: | Quotation,outline drawing,manufacturing plan, quality control plan testing plan, financial report, type test report(KEMA, CESI),reference list,etc |
| 5. Q: | What is your normal wanrranty period? |
| A: | 12 months after transformer operation. |
| 6. Q: | Can u do installation and commissioningin user’s site? |
| A: | Yes, we can send our installation team to user’s country for service. |
| 7. Q: | Do you have any experience in this kind of transformer? |
| A: | Yes, we can provide reference list for check. |
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China 40.5kv Vacuum Circuit Breaker with Current Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 40.5kv Vacuum Circuit Breaker with Current Transformer Products
Popular Circuit Breaker Products
VBI-12kv Indoor Vcb Front Mounted Vacuum Interrupters for Circuit Breaker
400 AMP 3 Pole Automatic Circuit Breaker with Overload, Short Circuit, Overvoltage Protection MCCB
MCCB Moulded Case Circuit Breaker
Factory 1200V 1500V DC Molded Case Circuit Breaker Electronic MCCB 63A 80A 100A 125A Price
Lw24-72.5/2000A-31.5ka High Voltage Sf6 Dead Tank Circuit Breaker 72.5kv 2000A
Popular cnville Products
Containerized Power Transformer Mobile Substation 69kv 33kv 20kv 11kv
Reactor, Dry Iron Core Shunt Reactors Voltage Capacity Customization Manufacture
Oltc Vacuum on Load Tap Changer for Power Transformer, Zm, Zmb, Zmd Type
Indicator Controller of on-Load Tap Changer Transformer Switch Controller
Popular Vacuum Circuit Breaker Products
12kv Vbi Front Mounted Mv Insulated Cylinder Vacuum Circuit Breaker Vcb
High Quality 12kv Indoor High Voltage Vacuum Circuit Breaker, Circuit Breaker Hva Series
Good Quality Vacuum Circuit Breaker, Circuit Breaker Leading Supplier for AIS Switchgear with CE
Vs1-24 Embedded Pole Type 24kv Handcraft Type Vcb Vacuum Circuit Breaker 2023
Tags: 40.5kv Vacuum Circuit Breaker with Current Transformer, Circuit Breaker, cnville, Vacuum Circuit Breaker