6.35/10kv XLPE Insulated Power Cable

China 
                        6.35/10kv XLPE Insulated Power Cable
                      manufacture and supplier

6.35/10kv XLPE Insulated Power Cable image

Get Latest Price Request a quote

Quick Details

6.35/10kv XLPE Insulated Power Cable

YJV/YJV22/YJV32

Henan Jiapu

ISO, CE, SABS

XLPE

AC Cable

Low and Medium Voltage Cable

Construction, Underground

0.6/1 Kv 3.6/6 Kv

1-5 Cores

IEC60502 IEC60331 DIN BS

90 Degrees

Jiapu

Wooden Drum or Wooden&Steel Drum

IEC, ASTM, DIN, BS, GB, Any standard

Henan China

4101962331

Product Details

6.35/10kV XLPE Insulated Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:

Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 2.5 0.12 1.5 17.6 0.34 0.49 1.2000 0.7270
35 7.0 2.5 0.12 1.5 18.5 0.39 0.60 0.8680 0.5240
50 8.3 2.5 0.12 1.6 20.0 0.46 0.74 0.6410 0.3870
70 9.7 2.5 0.12 1.6 21.5 0.55 0.96 0.4430 0.2680
95 11.3 2.5 0.12 1.7 23.3 0.66 1.23 0.3200 0.1930
120 13 2.5 0.12 1.7 24.8 0.77 1.48 0.2530 0.1530
150 14.6 2.5 0.12 1.8 26.4 0.87 1.77 0.2060 0.1240
185 15.9 2.5 0.12 1.8 28.1 1.01 2.13 0.1640 0.0991
240 18.3 2.6 0.12 1.9 30.9 1.23 2.71 0.1250 0.0754
300 20.4 2.8 0.12 2.0 33.6 1.48 3.32 0.1000 0.0601
400 23.2 3.0 0.12 2.1 37.0 1.81 4.16 0.0778 0.0470
500 26.4 3.2 0.12 2.2 41.1 2.24 5.27 0.0605 0.0366
630 30.1 3.2 0.12 2.3 45.0 2.73 6.62 0.0469 0.0283

2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 3.4 0.12 1.5 19.4 0.40 0.55 1.2000 0.7270
35 6.9 3.4 0.12 1.6 20.5 0.45 0.66 0.8680 0.5240
50 8.2 3.4 0.12 1.6 21.8 0.52 0.80 0.6410 0.3870
70 9.7 3.4 0.12 1.7 23.5 0.62 1.03 0.4430 0.2680
95 11.3 3.4 0.12 1.7 25.1 0.73 1.30 0.3200 0.1930
120 12.8 3.4 0.12 1.8 26.8 0.85 1.56 0.2530 0.1530
150 14.2 3.4 0.12 1.8 28.2 0.95 1.85 0.2060 0.1240
185 15.9 3.4 0.12 1.9 30.1 1.10 2.22 0.1640 0.0991
240 18.3 3.4 0.12 2.0 32.7 1.33 2.80 0.1250 0.0754
300 20.4 3.4 0.12 2.0 34.8 1.54 3.39 0.1000 0.0601
400 23.2 3.4 0.12 2.2 38.0 1.87 4.22 0.0778 0.0470
500 26.4 3.4 0.12 2.2 41.5 2.26 5.29 0.0605 0.0366
630 30.1 3.4 0.12 2.4 45.6 2.78 6.67 0.0469 0.0283

3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 4.5 0.12 1.6 21.8 0.48 0.63 1.2000 0.7270
35 6.9 4.5 0.12 1.7 22.9 0.54 0.75 0.8680 0.5240
50 8.2 4.5 0.12 1.7 24.2 0.61 0.89 0.6410 0.3870
70 9.7 4.5 0.12 1.8 25.9 0.72 1.13 0.4430 0.2680
95 11.3 4.5 0.12 1.8 27.5 0.84 1.40 0.3200 0.1930
120 12.8 4.5 0.12 1.9 29.2 0.96 1.67 0.2530 0.1530
150 14.2 4.5 0.12 1.9 30.6 1.06 1.96 0.2060 0.1240
185 15.9 4.5 0.12 2.0 32.5 1.22 2.34 0.1640 0.0991
240 18.3 4.5 0.12 2.1 35.1 1.46 2.93 0.1250 0.0754
300 20.4 4.5 0.12 2.1 37.2 1.68 3.52 0.1000 0.0601
400 23.2 4.5 0.12 2.2 40.2 2.00 4.35 0.0778 0.0470
500 26.4 4.5 0.12 2.3 43.9 2.43 5.45 0.0605 0.0366
630 30.1 4.5 0.12 2.4 47.8 2.93 6.83 0.0469 0.0283

4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25                  
35 6.9 5.5 0.12 1.7 24.9 0.62 0.83 0.8680 0.5240
50 8.2 5.5 0.12 1.8 26.4 0.70 0.98 0.6410 0.3870
70 9.7 5.5 0.12 1.8 27.9 0.80 1.21 0.4430 0.2680
95 11.3 5.5 0.12 1.9 29.7 0.94 1.50 0.3200 0.1930
120 12.8 5.5 0.12 1.9 31.2 1.05 1.77 0.2530 0.1530
150 14.2 5.5 0.12 2.0 32.8 1.17 2.07 0.2060 0.1240
185 15.9 5.5 0.12 2.0 34.5 1.33 2.45 0.1640 0.0991
240 18.3 5.5 0.12 2.1 37.1 1.57 3.04 0.1250 0.0754
300 20.4 5.5 0.12 2.2 39.4 1.81 3.66 0.1000 0.0601
400 23.2 5.5 0.12 2.3 42.4 2.14 4.49 0.0778 0.0470
500 26.4 5.5 0.12 2.4 46.1 2.58 5.61 0.0605 0.0366
630 30.1 5.5 0.12 2.4 49.8 3.10 6.99 0.0469 0.0283

5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25                  
35                  
50 8.2 8.0 0.12 2.0 31.8 0.95 1.23 0.6410 0.3870
70 9.7 8.0 0.12 2.0 33.3 1.07 1.47 0.4430 0.2680
95 11.3 8.0 0.12 2.1 35.1 1.21 1.78 0.3200 0.1930
120 12.8 8.0 0.12 2.1 36.6 1.34 2.05 0.2530 0.1530
150 14.2 8.0 0.12 2.2 38.2 1.47 2.37 0.2060 0.1240
185 15.9 8.0 0.12 2.2 39.9 1.64 2.76 0.1640 0.0991
240 18.3 8.0 0.12 2.3 42.5 1.90 3.37 0.1250 0.0754
300 20.4 8.0 0.12 2.4 44.8 2.16 4.01 0.1000 0.0601
400 23.2 8.0 0.12 2.4 47.6 2.52 4.87 0.0778 0.0470
500 26.4 8.0 0.12 2.5 51.3 2.98 6.01 0.0605 0.0366
630 30.1 8.0 0.12 2.6 55.2 3.54 7.43 0.0469 0.0283

6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 2.5 0.1 2.0 34.6 1.13 1.58 1.2000 0.7270
35 6.9 2.5 0.1 2.1 36.8 1.29 1.92 0.8680 0.5240
50 8.2 2.5 0.1 2.2 39.8 1.51 2.36 0.6410 0.3870
70 9.7 2.5 0.1 2.3 43.2 1.81 3.04 0.4430 0.2680
95 11.3 2.5 0.1 2.4 46.9 2.17 3.87 0.3200 0.1930
120 12.8 2.5 0.1 2.4 50.1 2.53 4.69 0.2530 0.1530
150 14.2 2.5 0.1 2.5 53.3 2.90 5.60 0.2060 0.1240
185 15.9 2.5 0.1 2.6 57.2 3.40 6.77 0.1640 0.0991
240 18.3 2.6 0.1 2.8 63.2 4.12 8.55 0.1250 0.0754
300 20.4 2.8 0.1 3.0 69.0 4.89 10.46 0.1000 0.0601
400 23.2 3.0 0.1 3.4 76.7 6.10 13.18 0.0778 0.0470
500 26.4 3.2 0.1 3.6 85.7 8.10 16.55 0.0605 0.0366

7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 3.4 0.1 2.1 38.7 1.30 1.75 1.2000 0.7270
35 6.9 3.4 0.1 2.2 40.9 1.47 2.22 0.8680 0.5240
50 8.2 3.4 0.1 2.3 43.9 1.70 2.50 0.6410 0.3870
70 9.7 3.4 0.1 2.4 47.3 2.02 3.25 0.4430 0.2680
95 11.3 3.4 0.1 2.5 51.0 2.42 4.12 0.3200 0.1930
120 12.8 3.4 0.1 2.6 54.4 2.79 4.95 0.2530 0.1530
150 14.2 3.4 0.1 2.7 57.6 3.17 5.87 0.2060 0.1240
185 15.9 3.4 0.1 2.8 61.5 3.69 7.06 0.1640 0.0991
240 18.3 3.4 0.1 2.9 66.9 4.38 8.82 0.1250 0.0754
300 20.4 3.4 0.1 3.1 71.8 5.11 10.68 0.1000 0.0601
400 23.2 3.4 0.1 3.3 78.3 6.24 13.32 0.0778 0.0470
500 26.4 3.4 0.1 3.5 86.4 7.63 16.50 0.0605 0.0366

8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25 6.0 4.5 0.1 2.3 43.9 1.57 2.02 0.9270 0.7270
35 6.9 4.5 0.1 2.4 46.0 1.75 2.38 0.6680 0.5240
50 8.2 4.5 0.1 2.4 48.8 2.00 2.85 0.4936 0.3870
70 9.7 4.5 0.1 2.5 52.3 2.34 3.57 0.3420 0.2680
95 11.3 4.5 0.1 2.6 55.9 2.75 4.45 0.2464 0.1930
120 12.8 4.5 0.1 2.7 59.4 3.16 5.32 0.1955 0.1530
150 14.2 4.5 0.1 2.8 62.6 3.57 6.27 0.1587 0.1240
185 15.9 4.5 0.1 2.9 66.4 4.07 7.45 0.1271 0.0991
240 18.3 4.5 0.1 3.1 72.0 4.82 9.25 0.0976 0.0754
300 20.4 4.5 0.1 3.3 77.0 5.71 11.28 0.0778 0.0601
400 23.2 4.5 0.1 3.4 83.2 6.78 13.86 0.0615 0.0470
500 26.4 4.5 0.1 3.5 91.1 8.20 17.32 0.0487 0.0366

9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm2 mm mm kg/m kg/m Ω/km Ω/km
25                
35 6.9 5.5 0.1 2.4 50.3 2.00 2.63 0.8680 0.6680
50 8.2 5.5 0.1 2.5 53.3 2.26 3.11 0.6410 0.4936
70 9.7 5.5 0.1 2.6 56.8 2.62 3.85 0.4430 0.3420
95 11.3 5.5 0.1 2.8 60.6 3.07 4.77 0.3200 0.2464
120 12.8 5.5 0.1 2.9 64.1 3.49 5.65 0.2530 0.1955
150 14.2 5.5 0.1 3.0 67.3 3.91 6.61 0.2060 0.1587
185 15.9 5.5 0.1 3.1 71.2 4.44 7.81 0.1640 0.1271
240 18.3 5.5 0.1 3.3 76.8 5.21 9.64 0.1250 0.0976
300 20.4 5.5 0.1 3.3 81.3 6.10 11.66 0.1000 0.0778
400 23.2 5.5 0.1 3.5 87.7 7.20 14.28 0.0778 0.0615
500 26.4 5.5 0.1 3.8 96.0 9.15 17.80 0.0605 0.0487

10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor Normal Diameter of Conductor Normal Thickness of Insulation Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath Approx.
Overall Dia.
Approx. Net Weight Max. D.C. Resistance of Conductor at 20ºC
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm2 mm mm mm mm mm kg/m kg/m Ω/km Ω/km
25                  
35                  
50 8.2 8.0 0.1 2.9 64.9 3.02 3.87 0.6410 0.4936
70 9.7 8.0 0.1 3.0 68.4 3.42 4.65 0.4430 0.3420
95 11.3 8.0 0.1 3.1 72.0 3.89 5.59 0.3200 0.2464
120 12.8 8.0 0.1 3.3 75.7 4.39 6.54 0.2530 0.1955
150 14.2 8.0 0.1 3.3 78.7 4.85 7.55 0.2060 0.1587
185 15.9 8.0 0.1 3.4 82.6 5.42 8.79 0.1640 0.1271
240 18.3 8.0 0.1 3.5 88.0 6.22 10.66 0.1250 0.0976
300 20.4 8.0 0.1 3.7 92.9 7.20 12.77 0.1000 0.0778
400 23.2 8.0 0.1 3.9 99.3 8.38 15.46 0.0778 0.0615
500 26.4 8.0 0.1 4.2 107.6 10.15 18.85 0.0605 0.0487
 
 

We are China 6.35/10kv XLPE Insulated Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 6.35/10kv XLPE Insulated Power Cable Products

  • No related articles
  • Popular jpcable99 Products

    12kv XLPE Insulation Copper or Aluminium Swa Power Cable

    High Quality LV (Low Voltage) PVC Insulated Power Cable

    Copper Conductor PVC Insulated PVC Sheathed Power Cable

    High Quality ABC Overhead Cable

    Low Voltage 0.6/1kv ABC Cable for Overhead Use

    15kv Medium Voltage Armoured XLPE Power Cable

    Popular Power Cable Products

    N2xsy Copper Electrical Cable Aluminum Electric Cable XLPE Power Cable

    Underground Transmission Line Copper XLPE Insulated Poewr Cable

    600V Stranded Copper Solid AWG 8 10 12 Nylon Thhn Thwn Cable

    35kV Copper Conductor UD/LLDPE Cable Polyethylene Insulated power cable

    3X2.5mm2 Flexible Rubber Power Lead Sheathed Cable

    LLDPE, MDPE, PVC Low and Medium Voltage Primary Mv105 Cable

    Popular XLPE Insulated Power Cable Products

    0.6/1kv Copper Conductor XLPE Insulation Steel Tape Armoured PVC Jacket Power Cable

    High Quality IEC Standard Bttz Yttw Type Heavy Duty 750V 0.6/1kv 1 2 3 4 Core 150 Sq mm Fire Resistant Mineral Insulated Tape Screened Power Micc Copper Cable

    XLPE PVC Sheath Swa Power Cable

    3 Core Swa Armoured Mv Cable

    1.8/3kv Medium Voltage Power Cables Single Core Cables

    Multi-Core Medium Voltage Cu/Al XLPE Insulated Power Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION