| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 0.6/1kV 3-cores Cold Shrinkable Termination Kits | VLZ-1/3.0 | 10~16 | 0.6/1kV 3-cores Cold Shrinkable Joint | VLJ-1/3.0 | 10~16 |
| VLZ-1/3.1 | 25~50 | VLJ-1/3.1 | 25~50 | ||
| VLZ-1/3.2 | 70~120 | VLJ-1/3.2 | 70~120 | ||
| VLZ-1/3.3 | 150~240 | VLJ-1/3.3 | 150~240 | ||
| VLZ-1/3.4 | 300~400 | VLJ-1/3.4 | 300~400 | ||
| 0.6/1kV 4-cores Cold Shrinkable Termination Kits | VLZ-1/4.0 | 10~16 | 0.6/1kV 4-cores Cold Shrinkable Joint | VLJ-1/4.0 | 10~16 |
| VLZ-1/4.1 | 25~50 | VLJ-1/4.1 | 25~50 | ||
| VLZ-1/4.2 | 70~120 | VLJ-1/4.2 | 70~120 | ||
| VLZ-1/4.3 | 150~240 | VLJ-1/4.3 | 150~240 | ||
| VLZ-1/4.4 | 300~400 | VLJ-1/4.4 | 300~400 | ||
| 0.6/1kV 5-cores Cold Shrinkable Termination Kits | VLZ-1/5.0 | 10~16 | 0.6/1kV 5-cores Cold Shrinkable Joint | VLJ-1/5.0 | 10~16 |
| VLZ-1/5.1 | 25~50 | VLJ-1/5.1 | 25~50 | ||
| VLZ-1/5.2 | 70~120 | VLJ-1/5.2 | 70~120 | ||
| VLZ-1/5.3 | 150~240 | VLJ-1/5.3 | 150~240 | ||
| VLZ-1/5.4 | 300~400 | VLJ-1/5.4 | 300~400 |
| Test Project | Standard Requirements | Test Result/Conclusion | |||
| Power Frequency Voltage Test | 4kV/1min,No breakdown no flashover | Pass,meet the requirements | |||
| Power Frequency Voltage Test | 2.4kV/4 hours,No breakdown no flashover | Pass,meet the requirements |
8.7/15KV-Cold Shrinkable Cable Accessories
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 8.7/15kV 3-cores Cold Shrinkable Indoor Termination Kits | VLN-10/3.1 | 25~50 | 8.7/15kV Single Core Cold Shrinkable Indoor Termination Kits | VLN-10/1.1 | 25~50 |
| VLN-10/3.2 | 70~120 | VLN-10/1.2 | 70~120 | ||
| VLN-10/3.3 | 150~240 | VLN-10/1.3 | 150~240 | ||
| VLN-10/3.4 | 300~400 | VLN-10/1.4 | 300~400 | ||
| VLN-10/3.5 | 500~630 | VLN-10/1.5 | 500~630 | ||
| 8.7/15kV 3-cores Cold Shrinkable Outdoor Termination Kits | VLW-10/3.1 | 25~50 | 8.7/15kV Single Core Cold Shrinkable Outdoor Termination Kits | VLW-10/1.1 | 25~50 |
| VLW-10/3.2 | 70~120 | VLW-10/1.2 | 70~120 | ||
| VLW-10/3.3 | 150~240 | VLW-10/1.3 | 150~240 | ||
| VLW-10/3.4 | 300~400 | VLW-10/1.4 | 300~400 | ||
| VLW-10/3.5 | 500~630 | VLW-10/1.5 | 500~630 | ||
| 8.7/15kV 3-cores Cold Shrinkable Joint | VLJ-10/3.1 | 25~50 | 8.7/15kV Single Core Cold Shrinkable Joint | VLJ-10/1.1 | 25~50 |
| VLJ-10/3.2 | 70~120 | VLJ-10/1.2 | 70~120 | ||
| VLJ-10/3.3 | 150~240 | VLJ-10/1.3 | 150~240 | ||
| VLJ-10/3.4 | 300~400 | VLJ-10/1.4 | 300~400 | ||
| VLJ-10/3.5 | 500~630 | VLJ-10/1.5 | 500~630 |
| Test Project | Standard Requirements | Test Result/Conclusion | |||
| Power Frequency Voltage | 39kV 5min Not Flashover and Not Breakdown | Pass | |||
| Partial Discharge | Under 15kV, Discharge volume≤10pc | Pass | |||
| Impulse Voltage Test | Under 95kV, ±10 times,No breakdown no flashover | Not Flashover and Not Breakdown | |||
| Constant Voltage load Cycle (in air) | The conductor applied voltage 23kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cycles | Not Flashover and assessed by the following test results | |||
| Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC) | Under 15kV, Discharge volume≤10pc | Pass | |||
| Constant load Cycle Test | The conductor applied voltage 23kV, and heated to (95-100ºC). In which the temperature stability 2h, cooling 3h, a total of 60 cycles | Not Flashover and assessed by the following test results | |||
| Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC,and at ambient temperature) | Under 15kV, Discharge volume≤10pc | Pass | |||
| Thermal Stability Test | Under 23 KA, Short circuit 2 times, No visible damage | Pass | |||
| Dynamic Stability Test | Under 81 KA, Short circuit 1 time, No visible damage | Pass | |||
| Impulse Voltage Test | 95kV, ±10 times | Not Flashover and Not Breakdown | |||
| AC Withstand Voltage | 23kV, 15min | Not Flashover and Not Breakdown | |||
| Tide Temperature Test | 11kV, 300h | Not Flashover,Not Breakdown and No Overcurrent Release | |||
| Salt Spray Test | 11kV, 1000h | Not Flashover,Not Breakdown and No Overcurrent Release |
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 18/20kV 3-cores Cold Shrinkable Indoor Termination Kits | VLN-20/3.1 | 35~70 | 18/20kV Single Core Cold Shrinkable Indoor Termination Kits | VLN-10/1.1 | 35~70 |
| VLN-20/3.2 | 95~185 | VLN-10/1.2 | 95~185 | ||
| VLN-20/3.3 | 240~400 | VLN-10/1.3 | 240~400 | ||
| VLN-20/3.4 | 500~630 | VLN-10/1.4 | 500~630 | ||
| 18/20kV 3-cores Cold Shrinkable Outdoor Termination Kits | VLW-20/3.1 | 35~70 | 18/20kV Single Core Cold Shrinkable Outdoor Termination Kits | VLW-10/1.1 | 35~70 |
| VLW-20/3.2 | 95~185 | VLW-10/1.2 | 95~185 | ||
| VLW-20/3.3 | 240~400 | VLW-10/1.3 | 240~400 | ||
| VLW-20/3.4 | 500~630 | VLW-10/1.4 | 500~630 | ||
| 18/20kV 3-cores Cold Shrinkable Joint | VLJ-20/3.1 | 35~70 | 18/20kV Single Core Cold Shrinkable Joint | VLJ-10/1.1 | 35~70 |
| VLJ-20/3.2 | 95~185 | VLJ-10/1.2 | 95~185 | ||
| VLJ-20/3.3 | 240~400 | VLJ-10/1.3 | 240~400 | ||
| VLJ-20/3.4 | 500~630 | VLJ-10/1.4 | 500~630 |
| Test Project | Standard Requirements | Test Result/Conclusion | |||
| Power Frequency Voltage | 54kV 5min Not Flashover and Not Breakdown | Pass | |||
| Partial Discharge | Under 20kV, Discharge volume≤10pc | Pass | |||
| Impulse Voltage Test | Under 125kV, ±10 times,No breakdown no flashover | Not Flashover and Not Breakdown | |||
| Constant Voltage load Cycle (in air) | The conductor applied voltage 35kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cycles | Not Flashover and assessed by the following test results | |||
| Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC) | Under 20kV, Discharge volume≤10pc | Pass | |||
| Constant load Cycle Test | The conductor applied voltage 35kV, and heated to (95-100ºC). In which the temperature stability 2h, cooling 3h, a total of 60 cycles | Not Flashover and assessed by the following test results | |||
| Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC,and at ambient temperature) | Under 20kV, Discharge volume≤10pc | Pass | |||
| Thermal Stability Test | Under 23 KA, Short circuit 2 times, No visible damage | Pass | |||
| Dynamic Stability Test | Under 81 KA, Short circuit 1 time, No visible damage | Pass | |||
| Impulse Voltage Test | 125kV, ±10 times | Not Flashover and Not Breakdown | |||
| AC Withstand Voltage | 30kV, 15min | Not Flashover and Not Breakdown | |||
| Tide Temperature Test | 15kV, 300h | Not Flashover,Not Breakdown and No Overcurrent Release | |||
| Salt Spray Test | 15kV, 1000h | Not Flashover,Not Breakdown and No Overcurrent Release |
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 26/35kV 3-cores Cold Shrinkable Indoor Termination Kits | VLN-35/3.1 | 50~95 | 26/35kV Single Core Cold Shrinkable Indoor Termination Kits | VLN-35/1.1 | 35~70 |
| VLN-35/3.2 | 120~185 | VLN-35/1.2 | 95~185 | ||
| VLN-35/3.3 | 240~400 | VLN-35/1.3 | 240~400 | ||
| VLN-35/3.4 | 500~630 | VLN-35/1.4 | 500~630 | ||
| 26/35kV 3-cores Cold Shrinkable Outdoor Termination Kits | VLW-35/3.1 | 50~95 | 26/35kV Single Core Cold Shrinkable Outdoor Termination Kits | VLW-35/1.1 | 35~70 |
| VLW-35/3.2 | 120~185 | VLW-35/1.2 | 95~185 | ||
| VLW-35/3.3 | 240~400 | VLW-35/1.3 | 240~400 | ||
| VLW-35/3.4 | 500~630 | VLW-35/1.4 | 500~630 | ||
| 26/35kV 3-cores Cold Shrinkable Joint | VLJ-35/3.1 | 50~95 | 26/35kV Single Core Cold Shrinkable Joint | VLJ-35/1.1 | 35~70 |
| VLJ-35/3.2 | 120~185 | VLJ-35/1.2 | 95~185 | ||
| VLJ-35/3.3 | 240~400 | VLJ-35/1.3 | 240~400 | ||
| VLJ-35/3.4 | 500~630 | VLJ-35/1.4 | 500~630 |
| Test Project | Standard Requirements | Test Result/Conclusion | |||
| Power Frequency Voltage | 105kV 1min Not Flashover and Not Breakdown | Pass | |||
| Partial Discharge | Under 39kV, Discharge volume≤10pc | Pass | |||
| Constant Voltage load Cycle (in air) | The conductor applied voltage 23kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cycles | Not Flashover and assessed by the following test results | |||
| Impulse Voltage Test | Under 250kV, ±10 times,No breakdown no flashover | Not Flashover and Not Breakdown | |||
| DC Voltage | 156kV, 15min | Not Flashover and Not Breakdown | |||
| AC Withstand Voltage | 104kV, 4h | Not Flashover and Not Breakdown |
View more products,you can click photos…
66~500kV High Voltage Cable Accessories 1~35kV Heat Shrink Cable Accessories Grounding Box
Customized Silicone Rubber Protector Heat Shrinkable Tubing Explosion Proof Box
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China 1kv 1~5 Cores Cold Shrinkable Straight Joint Kit manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1kv 1~5 Cores Cold Shrinkable Straight Joint Kit Products
Popular Cold Shrink Joint Kit Products
Easy Installation High Voltage 33kv Cold Shrink Indoor Terminal
Factory Direct Supply 1~35kv Cold Shrinkable Termination Kits
High Quality Cold Insulation Cable Accessories Cold Shrink Cable Joint Kit
Cold Insulation Cable Accessories Cold Shrink Cable Joint Kit
35kv High Voltage Three-Core Cold Shrinkable Intermediate Connector Cable Joint Kits
10kv 3 Cores Cold Shrink Cable Connector Set Straight Joint Kit
Popular Indoor Termination Kit Products
Factory Direct Supply 1~35kv Cold Shrinkable Termination Kits
1low Voltage 4-Core Cold Shrinkable Cable Accessories Termination Kit
Outdoor Cold Shrinkable Termination Kits Indoor Cable Cold Shrink Joint Kit
Cold Insulation Cable Accessories Cold Shrink Cable Joint Kit
20kv 3-Cores Cold Shrinkable Termination Kits
3 Core High Voltage Cable Straight Joint Intermediate Joint
Popular jiuweielectric Products
Direct Supply 2 Cores Heat Shrinkable Cable Breakout
Vdrs-Φ 3.5/1.75 1kv Low Voltage Heat Shrinkable Sleeve/Tube/Pipe
Vsbg Shrink Ratio 3X 4X Dual Wall Heat Shrink Tubing with Adhesive Inside
Factory Direct Supply 10kv Heat Shrinkable Busbar Tubes Y/G Flexible Insulation Tube
Heat Resistant Electric PVC Insulating Tape
9V Supply Cold Shrink 3-Cores Silicone Rubber Cable Breakout Boots
Tags: 1kv 1~5 Cores Cold Shrinkable Straight Joint Kit, Cold Shrink Joint Kit, Indoor Termination Kit, jiuweielectric