Triplex Service Drop Overhaed Bundled Cable with XLPE Insulated AAC Conductor

China 
                        Triplex Service Drop Overhaed Bundled Cable with XLPE Insulated AAC Conductor
                      manufacture and supplier

Triplex Service Drop Overhaed Bundled Cable with XLPE Insulated AAC Conductor image

Get Latest Price Request a quote

Quick Details

Triplex Service Drop Overhaed Bundled Cable with XLPE Insulated AAC Conductor

Triplex Service Drop cable

Jytop

ISO9001, CCC

Primarily Overhead Secondary Distribution

Round Wire

XLPE

PVC

Aluminum

Overhead

Stranded

Insulated

Asrm B-230 / Asrm B-231/ Asrm B-232/Asrm B-399

25 ºC

75ºC

0.91

0.95

JYTOP

500m / Rolls

ASTM standards

Zhengzhou, China

8544492100

Product Details

Triplex Service Drop Overhaed bundled Cable with XLPE Insulated AAC Conductor 

Construction:
Conductors are concentric stranded, compressed conductors of aluminum 1350-H19, Insulated with either polyethylene or XLP cross-linked polyethylene, ,Neutral messengers are concentrically stranded 6201, AAC or ACSR .
 

 
Applications:
triplex Service Drop is to supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation or 90°C maximum for cross-linked polyethylene (XLP) insulated 
 
Standards:
Triplex service drop cable meets or exceeds the following ASTM specifications:
ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-399 Concentric-Lay-Stranded Aluminum Alloy Conductors 6201-T81.
 
Service drop cable meets or exceeds all applicable requirement of ANSI/ ICEA-S-76-474:

Technical date :

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Size (kcmil) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAAC 6201 ALLOY FULL NEUTRAL MESSENGER
Minex 6 1 45 6 30.58 7 1110 101 101 85 70
Hippa 6 7 45 6 30.58 7 1110 107 107 85 70
Prawn 4 1 45 4 48.69 7 1760 152 152 115 90
Barnacle 4 7 45 4 48.69 7 1760 160 160 115 90
Shrimp 2 7 45 2 77.47 7 2800 243 243 150 120
Gammarus 1/0 7 60 1/0 123.3 7 4460 390 390 205 160
Leda 1/0 9 60 1/0 123.3 7 4460 384 384 205 160
Dunganese 2/0 7 60 2/0 155.4 7 5390 474 474 235 185
Cyclops 2/0 11 60 2/0 155.4 7 5390 474 474 235 185
Flustra 3/0 17 60 3/0 195.7 7 6790 587 587 275 215
Lepas 4/0 18 60 4/0 246.9 7 8560 728 728 315 245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Size (kcmil) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAAC 6201 ALLOY REDUCED NEUTRAL MESSANGER
Artemia 4 1 45 6 30.58 7 1110 135 135 115 90
Crab 4 7 45 6 30.58 7 1110 143 143 115 90
Solaster 2 7 45 4 48.69 7 1760 216 216 150 120
Sandcrab 1/0 7 60 2 77.47 7 2800 347 347 205 160
Echinus 1/0 9 60 2 77.47 7 2800 341 341 205 160
Crayfish 2/0 7/w 60 mls 2/0 7 2510 485.8 455.3 235 Amps 185 Amps
Sipho 2/0 7/w 60 mls 2/0 7 2510 485.8 455.3 235 Amps 185 Amps
Fulgar 3/0 17 60 1/0 123.3 7 4460 519 519 275 215
Arca 4/0 18 60 2/0 155.4 7 5390 643 643 315 245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+……………
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAC NEUTRAL-MESSENGER
Haiotis 6 7/w 45 mls 6 7 563 109.1 101.6 85 Amps 70 Amps
Patella 6 7 45 6 7 563 103 103 85 70
Fusus 4 7/w 45 mls 4 7 881 161.8 151.7 115 Amps 90 Amps
Oyster 4 7 45 4 7 881 154 154 115 90
Clam 2 7 45 2 7 1350 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 696 696 315 245
Nannynose 336.4 19 80 336.4 19 6146 1118 1118 420 325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
ASCR NEUTRAL-MESSENGER
Paludina 6 1 45 6 6/1 1190 109 109 85 70
Voluta 6 7 45 6 6/1 1190 114 114 86 70
Whelk 4 1 45 4 6/1 1860 164 115 90
Periwinkle 4 7 45 4 6/1 1860 172 172 115 90
Conch 2 7 60 1/0 6/1 4380 420 420 205 160
Neritina 1/0 7 60 1/0 6/1 4380 420 420 205 160
Cenia 1/0 9 60 1/0 6/1 4380 414 414 205 160
Runcina 2/0 7 60 2/0 6/1 5310 520 520 235 185
Triton 2/0 11 60 2/0 6/1 5310 512 512 235 185
Mursia 3/0 17 60 3/0 6/1 6620 635 635 275 215
Zuzara 4/0 18 60 4/0 6/1 8350 789 789 315 245
Limpet 336.4 19 80 336.4 18/1 8680 1167 1167 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
ASCR REDUCED NEUTRAL-MESSENGER
Scallop 4 1 45 6 6/1 1190 142 115 90
Strombus 4 7 45 6 6/1 1190 151 151 115 90
Cockle 2 7 45 4 6/1 1190 220 220 150 120
Janthina 1/0 7 60 2 6/1 2853 366 366 205 160
Ranella 1/0 9 60 2 6/1 2853 360 360 205 160
Cavolinia 2/0 7 60 1 6/1 3550 453 453 235 185
Clio 2/0 11 60 1 6/1 3550 444 444 235 185
Sanddollar 3/0 19/w 60 mls 1/0 6/1 4380 565 552 275 Amps 215 Amps
Aega 3/0 17 60 1/0 6/1 4380 549 549 275 215
Cuttlefish 4/0 19/w 60 mls 2/0 6/1 5310 699 684 315 Amps 245 Amps
Cerapus 4/0 18 60 2/0 6/1 5310 681 681 315 245
Cowery 336.4 19 80 mls 336/4 18/1 8680 1209 1167 420 Amps 325 Amps
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

We are China Triplex Service Drop Overhaed Bundled Cable with XLPE Insulated AAC Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Aerial Bundled Cable Products

Service Drop Cable Aerial Bunched Cable Overhead ABC Cable

1/0 2/0 3/0 4/0 AWG Urd Power Cable, for Underground Distribution Urd Cable

Aluminum Conductor Three-Core Steel Wire 0.6/1 Kv ABC Cable

Stranding Bare Aluminum Conductor 1/0 2/0 2/4/6AWG Single Core Covered Line Wire

33kv Aluminium Conductor Abc Aerial Bundled Cable

Aerial Bundle Cable ABC to Sans 1418 Size 3X70+54.6

Popular jytopcable Products

Flexible Rubber Insulated Cable 35sq. mm

Experienced Facotry Supply for PVC Insulated Electric Wire

Medium Voltage Mv Tr-XLPE Insulated Urd Steel Wire Armoured Underground Cable

H03V-U PVC Insulated Electric Wire

1kv Nyfy Electrical Cable Low Voltage LV Nyry Electric Cable 3X70+1X35sq. Mm

Yjv 110kv-132kv XLPE Insulated 4core 95mm Power Cable

Popular Overhead Aluminum Cable Products

Bare Conductor ACSR Aluminium Conductor Steel Reinforced for Power Transmission Line, Overhead Bare Cable Wires.

Quadraplex Service Drop Overhead Aluminum Cable

4 Core 95mm Aluminum Conductor Aerial Bundle Cable

Bare Aluminum Conductor AAAC / AAC ACSR 240/40 mm2 Rabbit Conductor Overhead Aluminum Bare Conductors

Overhead ACSR Conductor 397.5mcm Ibis Brant Lark Bare Aluminum Overhead High Voltage Free for Power Transmission

Single Core PE Insulation 95mm2 Overhead Aluminum Cable

Popular Triplex Service Drop Cable Products

Triplex Service Drop Cable

XLPE PE PVC Insulated Aerial Bundled Electrical ABC Cable

600volt Secondary Ud Aluminum Conductor XLPE Insulation Triplex Bundled Cable

Nannynose XLPE Insulated Overhead Aluminum Triplex Service Drop Cable

Aluminium Wire and Cable Electric Project AAC AAAC ACSR ABC Cable

0.6/1kv Triplex Service Drop Cable Gammarus 2X1/0wg+1X123.3 AAAC Neutral Messenger

Tags: , , ,