off-Circuit Capacity Regulating Tap Changer Circuit Switch
off-Circuit Capacity Regulating Tap Changer Circuit Switch image
Get Latest Price Request a quote
Basic Info.
Product Description
Introduction:
This type of tap changer is designed as step changeable facility used for capacity regulating transformer under
non-energized condition. It is suitable for three-phase oi-immersed capacity regulating with voltage rated 10kV
and below, rated capacity 315kVA and below. It can be connected in series and parallel system on LV and HV
windings or connected b star or delta method through which to realize transformer capacity changeable. By this
way we can reduce iron loss and increase transformer load efficiency and power factor avoiding the
phenomenon of “Big horse will drag small carriage”, and can be used to regulate voltage terminals.
Technical parameters:
| Main performance parameter | Insulation Leve (kV) | Sealing performance (Pa/24h) | Machine Life(Ten thousand times) | Rated through current (A) |
Heat Stableness current (kA/2s) |
Dynamic stableness current (kA) | Moment of force (N@m) | Revalue of contact emperature (K) |
Value of Contact resistant (μΩ) | ||||||
| Line-frequency ( 1 min ) | ( 1.2/50 μs) | ||||||||||||||
| Rated Voltage class (Kv) | Wiring mode | To ground | Inter phase | Inter contactor | To ground | Inter phase |
Inter contactor |
||||||||
| 10 | Neutral point | 42 | 10 | 10 | 150 | 120 | 85 | 6×10 4 | 1 | 20 | 0.5 | 1.25 | ≤5 | ≤20 | ≤350 |
| 63 | 1.57 | 3.9 | |||||||||||||
| Middle part | 42 | 42 | 18 | 150 | 150 | 85 | 125 | 2.5 | 6.25 | ≤10 | |||||
| 35 | Neutral point | 95 | 35 | 12 | 200 | 150 | 90 | 250 | 5 | 12.5 | |||||
| Middle part | 95 | 95 | 30 | 200 | 200 | 90 | 400 | 6 | 15 | ≤15 | |||||
| 66 | Neutral point | 140 | 100 | 30 | 325 | 230 | 100 | 500 | 7.5 | 18.75 | |||||
| Middle part | 140 | 140 | 45 | 325 | 325 | 150 | 630 | 9.45 | 23.6 | ≤20 | |||||
| 110 | Neutral point | 175 | 175 | 45 | 480 | 325 | 150 | 1000 | 10 | 25 | |||||
| Middle part | 230 | 230 | 55 | 480 | 480 | 175 | 1250 | 12.5 | 31.25 | ||||||
| 220 | Middle part | 460 | 400 | 90 | 1050 | 1050 | 285 | 1600 | 16 | 40 | ≤50 | ||||
| 2000 | 20 | 50 | |||||||||||||
Company profile:
Main product line: Tap changer and HV switchgear
Tap changer manufacturing with fullest vertical integration
Tap Changer Products Range On-Load Tap Changer:
* Conventional OLTC for transformer with voltage up to 765kV
*Vacuum OLTC for oil transformer with voltage up to 765kV
*Vacuum OLTC for dry transformer with voltage of 72.5kV
Off-Circuit Tap Changer
* Application for the transformer with voltage up to 765kV
Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and please trust both of us will create a brilliant future!
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China off-Circuit Capacity Regulating Tap Changer Circuit Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular cnville Products
8mva 110kv Dual-Winding No-Load Tapping Power Transformer 8000kVA
Drawable AC Metal-Clad Switch Gear; Switchgear; C-Gis
Gw23b Series Outdoor Hv AC Isolating Switch
Oil Type Three Phase Shunt Reactor W/on-Load Tap Changer 20mva 132kv
Lvqb-66W3 Sf6 Gas-Insulated Inverted Current Transformer/Protect Current Transformer
Cubicle Fixed AC Metal-Clad Switchgear
Popular off-Circuit Capacity Regulating Tap Changer Circuit Switch Products
Popular tap changer Products
Transformer Switch /off-Circuit Tap Changer (Bar Form)
Vacuum Permanent-Magnet (horizontal) On Load Tap changer for Oil-immersed Transformer
63A WDP and WSP series De-energized tap-changer or Switch Tray-form For Transformer
Oil-immersed load switch (LBS) 12KV Transformer Tap Switcher Tap Changer
35kv De-energized Linearity Tap Changer WST WDT Series Switches
35kV De-energized linearity off circuit tap changer
Popular transformer tap changer Products
off-Circuit Cage-Form Tap-Changer Circuit Switch Distribution Transformer off Load Tap Changer
Vacuum on-Load Tap Changers for Oil Immersed Transformer Switch off Circuit Tap Changer
on-Load Tap Changer for Transformer Load Break Switch Tap Changer
Wdg Type B off-Circuit Tap Changer for Transformers
Zmd High-Quality on-Load Tap-Changer Below 252kv for Three Phase Neutral Point Voltage Regulation
Tags: cnville, off-Circuit Capacity Regulating Tap Changer Circuit Switch, tap changer, transformer tap changer