Fnl6a-12 Series 12kv Load Switch
Fnl6a-12 Series 12kv Load Switch image
Get Latest Price Request a quote
Basic Info.
Product Description
General:
FNl6A-12 series switch is suitable for AC 50Hz, rated voltage 10kV network, especially for oil-free, maintenance
and frequent operation places to break load current, overload current and close short-circuit current. The
combined electric equipment breaks short-circuit current. It can be controlled through CS6-1 operating
mechanism or specialized CS operating mechanism or directly at the back of switch without operating
mechanism.
Characteristics:
1. All-assembled switch and combined equipment has small dimension and compact structure
2. Both manual and electric operating mechanism with small operating force
3. Reliable mechanical interlock prevents mal-operation
4. Clearly visible clearance
5. Apply air compression arc extinguishing with stable performance and reliable, safe operation
6. The combined electric equipment has open-phase protection function
Technical parameters:
| SI. NO. | Name | Unit | Data |
| 1 | Rated voltage and maximum working voltage | kV | 12 |
| 2 | Rated frequency | Hz | 50 |
| 3 | Rated current | A | 630 |
| 4 | Rated active load breaking current | A | 630 |
| 5 | Rated closed-loop breaking current | A | 630 |
| 6 | 5% rated active load breaking current | A | 31.5 |
| 7 | Rated breaking current of cable charging | A | 10 |
| 8 | Rated capacitance breaking current | A | 400 |
| 9 | Rated no-load transformer breaking current | 1600KVA transformer no-load current | |
| 10 | 1min power frequency withstand voltage (effective) to earth, inter-phase, vacuum clearance/isolation clearance | kV | 42/48 |
| 11 | Full wave lightning impulse withstand voltage(peak)to earth, inter-phase, vacuum clearance/isolation clearance | kV | 75/85 |
| 12 | Rated short-time withstand current(thermal stable) | kA/s | 20/3 |
| 13 | Rated peak withstand current(dynamic stable) | kA | 50 |
| 14 | Rated short-circuit closing current | kA | 50 |
| 15 | Rated current breaking times | Times | 10000 |
| 16 | Mechanical life | Times | 10000 |
| 17 | The permissible accumulated wear thickness of contacts | mm | 3 |
| 18 | Breaking and closing operation torque(force) | Nm(N) | 120(240) |
| 19 | Rated closing operation voltage/current | V/A | AC/DC 220/0.5 |
| 20 | Rated breaking operation voltage/current | V/A | AC/DC 220/3 |
Technical parameter of FN16A-12RD/200-31.5 load switch-fuse combined electric equipment:
| SI. NO. | Name | Unit | Data |
| 1 | Rated voltage and maximum working voltage | kV | 12 |
| 2 | Rated frequency | Hz | 50 |
| 3 | Fuse maximum rated current | A | 200 |
| 4 | Rated transfer current | A | 3150 |
| 5 | Fuse tube triggered breaking time of switch | ms | 31 |
| 6 | Rated short-circuit breaking current(anticipated effective value) | kA | 31.5 |
| 7 | Rated short-circuit closing current(anticipated peak value) | kA | 80 |
| 8 | 1min power frequency withstand voltage (effective) to earth, inter-phase, isolation clearance | kV | 42/48 |
| 9 | Lightning impulse withstand voltage(peak)to earth, inter-phase, isolation clearance | kV | 75/85 |
| 10 | Fuse striking output energy | J | 2-5 |
Our Services
|
1. |
Pre sale service |
|
a. |
make technical solution |
|
b. |
send quotation, technical data sheet and drawing |
|
c. |
prepare power transmission plan, testing plan,and shipment plan |
|
2. |
In sale service |
|
a. |
supervise the manufacturing schedule totally in accordance with the plan |
|
b. |
send photos to customer during every manufacturing process(hold point) |
|
c. |
inform the customer one week before testinng. |
|
3. |
After sale service |
|
a. |
installation and commissioning, training the workers |
|
b. |
quick response within 12 hours any time |
|
c. |
provide 12 months gurantee period normally. |
FAQ
|
1. Q: |
What is your delivery time ? |
|
A: |
Depend on the type of transformer. |
|
2. Q: |
What is your payment term? |
|
A: |
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
|
3. Q: |
What kind of starndard you follow? |
|
A: |
IEC, ANSI, CSA, GB, etc |
|
4. Q: |
What kind of supporting documentation you can provide normally |
|
A: |
Quotation,outline drawing,manufacturing plan, quality control plan |
|
5. Q: |
What is your normal wanrranty period? |
|
A: |
12 months after transformer operation. |
|
6. Q: |
Can u do installation and commissioningin user’s site? |
|
A: |
Yes, we can send our installation team to user’s country for service. |
|
7. Q: |
Do you have any experience in this kind of transformer? |
|
A: |
Yes, we can provide reference list for check. |
Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Fnl6a-12 Series 12kv Load Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular cnville Products
220kv Power Transmission/Distribution Transformer Low Noise Oil Immersed Power Transformer
500kw-50000kw Condensing Steam Turbine Small Steam Turbine
0.65mva 10kv Arc Furnace Transformer
66kv 110kv 220kv Tyd Single Phase Capacitor Voltage Transformer
24.04mva 35kv Electrolyed Electro-Chemistry Rectifier Transformer
Popular Fnl6a-12 Series 12kv Load Switch Products
Popular Load Switch Products
Fln36-24 24kv Indoor AC High Voltage Sf6 Load Switch for Switchgear
Fn3 Series Indoor Use, High Voltage Load Switch
35kv 230mm Lower Phase Distance High Voltage Indoor Load Switch for Switchgear
Fn5-12 Series Indoor AC Hv Load Switch-Fuse Combination Apparatus
12kv Fn7 High Voltage Air Load Break Switch for Switchgear
Indoor AC Load Switch11kv for Breaking Load Current and Closing Short-Circuit Current
Popular Vacuum Load Switch Products
Indoor High Voltage 12kv Fuse Combination Vacuum Load Switch Protection Device
Fzrw32-24/630-200 Load Switch 24kv Isolating Vacuum Load Switch for Transformer
Indoor AC Load Switch11kv for Breaking Load Current and Closing Short-Circuit Current
Tags: cnville, Fnl6a-12 Series 12kv Load Switch, Load Switch, Vacuum Load Switch