Aluminum Conductor XLPE Insulated ABC Electric Cables (JKLYJ)

China 
                        Aluminum Conductor XLPE Insulated ABC Electric Cables (JKLYJ)
                      manufacture and supplier

Aluminum Conductor XLPE Insulated ABC Electric Cables (JKLYJ) image

Get Latest Price Request a quote

Quick Details

Aluminum Conductor XLPE Insulated ABC Electric Cables (JKLYJ)

ABC Cable

Huatong

Jklv

ISO, CCC, CE, UL

Aluminium/Copper

Round Wire

None

PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Underground, Industrial, Power Station

PVC/PE/XLPE

40000m2

Power Distribution

HUATONG

Drum

GB/T 12527

China

8544492100

Product Details

Aluminium Service Drop
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.

ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.

ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

We are China Aluminum Conductor XLPE Insulated ABC Electric Cables (JKLYJ) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

ABC Cable, XLPE PVC Insulated Aerial Bundled Cable. Overhead Electric ABC Cable.

Duplex Service Dropcable, ABC Cable 70sqmm Aluminum Aerial Bunched Wires & Cables Supplier

Caai ABC Cable 0.6/1kv with AAAC Neutral (3X70+54.6+16 mm2)

0.6/1kv Twisted 35/50/70mm2 XLPE Insulation ABC Aerial Bundle Cable

ABC ABC XLPE Covered Conductor Cable 0.6/1kv Overhead Cable Aerial Bundle Conductor

Quadruplex Service Drop Cable, AAAC Neutral, Twisted 600 V Quadruplex (ANSI/ICEA S-76-474)

Popular Aluminium Conductor Products

Most Favored Type All Aluminium Conductor

AAC Aluminum Conductor/AAAC/ ACSR Overhead Cable/All Aluminum Cable

AAC Conductor Aluminium Stranded Conductor AAC Cable AAC Wire

Overhead Cable Aluminium Conductor ABC Cable 11kv

Holding Chain for Clamp

Overhead AAC/AAAC/ACSR/ABC Stranded Aluminium Wire for Transmission Line

Popular huatongcable Products

ANSI Standard Disc Suspension Insulator (52-1) for Transmission Line

ASTM Standard Bare Conductor AAC Peachbell /Rose/Iris/Poppy/Pansy

The Alumium Conductor Alloy Reinforced Acar

IEC 60227 Copper Conductor PVC Insulation Electric Wire BV 1.0mm2

Electric Hard Drawn Aluminum Conductor AAC Cable with ISO Certificate

Overhead Triplex Service Drop Carnea Aerial Bundled Cable for Transmission Line

Popular XLPE Insulated Products

Medium Voltage Steel Wire Armoured 3 Core 25mm 70mm Power Cable

Stranded Copper Conductor XLPE Insulated Multipair Individual & Collective Screen Flame Retardant PVC Sheath Cable

Nvv (NYM) PVC Insulated Multi-Core Cables with Copper Conductor

LV Cable Al/XLPE/PVC IRAM 2178 Standard 3X70/35mm2 0.6/1kV

NFC 33-209 ABC Cable Duplex Service Drop Aluminum Conductor XLPE Insulated Cable

Flame Retardant Copper Conductor STA Armoured XLPE Insulated LV Power Cable 0.6/1kV 2X10mm2