25mm2 PE Insulated ABC Cable
25mm2 PE Insulated ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
The assembled insulated conductor shall be suitable for use in a system having a standard operating voltage not exceeding 600/1000V. The cores of an aerial bundled conductor shall be laid-up with a left-hand lay. The length of lay shall be 55-75 times the diameter of a phase conductor.
Construction:
The conductors shall be stranded circular and ,except where otherwise stated,shall comply with all the requirement for class 2 compacted stranded circular conductors of IEC60502.
Workshop
Shipment
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
Specifications:
| (1)Self-supporting | |||||||||
| Phase | Phase | Phase | Approx.Overall Diameter | Max. D.C. Resistance of Conductor at 20 Centgrade | |||||
| AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||||
| No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Normal Thickness | Min. | Diameter | ||||
| No. X mm 2 | – | mm | mm | mm | mm | mm | ohm/km | ||
| 1 X 10 | 7 | 4.05 | 1 | 0.8 | 6.05 | 6.05 | 3.08 | ||
| 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.2 | 1.91 | ||
| 1 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 8.4 | 1.2 | ||
| 1 X 35 | 7 | 7 | 1.4 | 1.16 | 9.8 | 9.8 | 0.868 | ||
| 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 11.1 | 0.641 | ||
| 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 12.6 | 0.443 | ||
| 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 14.8 | 0.32 | ||
| 1 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 16.2 | 0.253 | ||
| 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.2 | 0.206 | ||
| 1 X 185 | 36 | 16.2 | 2 | 1.7 | 20.2 | 20.2 | 0.164 | ||
| 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 22.8 | 0.125 | ||
| 2 X 10 | 7 | 4.05 | 1 | 0.8 | 6.05 | 12.1 | 3.08 | ||
| 2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.4 | 1.91 | ||
| 2 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 16.8 | 1.2 | ||
| 2 X 35 | 7 | 7 | 1.4 | 1.16 | 9.8 | 19.6 | 0.868 | ||
| 2 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 22.2 | 0.641 | ||
| 2 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 25.2 | 0.443 | ||
| 2 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 29.6 | 0.32 | ||
| 2 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 32.4 | 0.253 | ||
| 2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.4 | 0.206 | ||
| 2 X 185 | 36 | 16.2 | 2 | 1.7 | 20.2 | 40.4 | 0.164 | ||
| 2 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 45.6 | 0.125 | ||
| 3 X 10 | 7 | 4.05 | 1 | 0.8 | 6.05 | 13.07 | 3.08 | ||
| 3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 1.91 | ||
| 3 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 18.14 | 1.2 | ||
| 3 X 35 | 7 | 7 | 1.4 | 1.16 | 9.8 | 21.17 | 0.868 | ||
| 3 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 23.98 | 0.641 | ||
| 3 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 27.22 | 0.443 | ||
| 3 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 31.97 | 0.32 | ||
| 3 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 34.99 | 0.253 | ||
| 3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 0.206 | ||
| 3 X 185 | 36 | 16.2 | 2 | 1.7 | 20.2 | 43.63 | 0.164 | ||
| 3 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 49.25 | 0.125 | ||
| 4 X 10 | 7 | 4.05 | 1 | 0.8 | 6.05 | 14.64 | 3.08 | ||
| 4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 1.91 | ||
| 4 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 20.33 | 1.2 | ||
| 4 X 35 | 7 | 7 | 1.4 | 1.16 | 9.8 | 23.72 | 0.868 | ||
| 4 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 26.86 | 0.641 | ||
| 4 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 30.49 | 0.443 | ||
| 4 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 35.82 | 0.32 | ||
| 4 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 39.2 | 0.253 | ||
| 4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 0.206 | ||
| 4 X 185 | 36 | 16.2 | 2 | 1.7 | 20.2 | 48.88 | 0.164 | ||
| 4 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 55.18 | 0.125 | ||
| (2) Phase + Messenger | |||||||||
| Phase | Messenger | Phase | Messenger | Approx.Overall Diameter | Max. D.C. Resistance of Conductor at 20 Centgrade | ||||
| AAC+UV-XLPE | AAAC | Compact Conductor | UV-XLPE Insulation | Conductor | |||||
| Phase | Messenger | ||||||||
| No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al.Wire | Overall Dia. | Normal Thickness | Min. | No./Dia. of Al Alloy Wire | |||
| No. X mm 2 | No. X mm 2 | – | mm | mm | Min. | No./mm | mm | ohm/km | ohm/km |
| 1 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.3 | 1.91 | 2.217 |
| 1 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 14.7 | 1.2 | 1.393 |
| 1 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 | 17.3 | 0.868 | 1.007 |
| 1 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.1 | 0.641 | 0.744 |
| 1 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.1 | 0.443 | 0.514 |
| 1 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.3 | 0.32 | 0.371 |
| 1 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 30.2 | 0.253 | 0.294 |
| 1 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 |
| 1 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 | 37.7 | 0.164 | 0.19 |
| 1 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0.125 | 0.145 |
| 2 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 |
| 2 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 16.63 | 1.2 | 1.393 |
| 2 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 | 19.51 | 0.868 | 1.007 |
| 2 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 |
| 2 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25.7 | 0.443 | 0.514 |
| 2 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.32 | 0.371 |
| 2 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 33.41 | 0.253 | 0.294 |
| 2 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 |
| 2 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 | 41.69 | 0.164 | 0.19 |
| 2 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0.125 | 0.145 |
| 3 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 |
| 3 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.2 | 1.393 |
| 3 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 |
| 3 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 |
| 3 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 |
| 3 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.32 | 0.371 |
| 3 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 | 37.87 | 0.253 | 0.294 |
| 3 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 |
| 3 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 | 47.25 | 0.164 | 0.19 |
| 3 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0.125 | 0.145 |
We are China 25mm2 PE Insulated ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
IEC60502 Standard High Performance Aerial Bundled Cable
0.6-1kv XLPE Insulated Service Aerial Bundled Aluminum Overhead ABC Cable
Low Voltage 4 Core 95mm2 ABC Cable for Sudan
French Standard NFC 33-209 Africa ABC Cable 3X70+54.6mm2 Aluminum Conductor XLPE Insulation
Best Popular ABC Cable for Overhead Cable 0.6/1kv LV
Low Voltage XLPE/PE Insulation 3X120mm2 ABC Aerial Bundled Electrical Cable
Popular Aerial Bundled Cable Products
3*70+70mm2 Overhead Line Cable/Aerial Bundled Cable
0.6/1kv Low Votage Overhead ABC Cable
ABC Cable, Insulated Aerial Cable, Aerial Bundled Cable (UL)
Covered Line Wire with Aluminum Conductor ABC Cable
Duplex, Triplex, Quadruplex Aerial Bundled Cable with ASTM, BS Standard
ABC Aerial Bundle Cable Aluminium Conductor for Overhead Line
Popular jpcable99 Products
High Quality Overhead Insulated Cable Covered Conductor
Cable De Fibra ó Ptica De Alto Voltaje PBT Opgw aé Reo De Alto Voltaje
12/20kv XLPE/Swa/PVC Power Cable 1*50 1*70
8.7/15kv Copper Conductor Cable XLPE Insulated Unarmoured Power Cable
Hot Seller 0.6/1kv 25mm2/ 50mm2 Aerial Bundled Cable
Low Voltage Cu/Al Core XLPE Insulated Steel Tape Armored Power Cable
Popular PE Insulated ABC Cable Products
600/1000V AAC Conductor PE Insulated Duplex Service Drop Aerial Cable
50mm2 70mm2 95mm2 Aluminum Stranded Conductor PE Insulated ABC Cable
Aluminum Stranded Conductor PE Insulated ABC Cable IEC Standard ABC Cable
AAC Conductor PE Insulated Duplex ABC Cable
AAC Phase Conductor XLPE/PE Insulated Cable Triplex ABC Overhead Cable
Aluminum Conductor Duplex Service Drop PE Insulated ABC Cable
Tags: ABC Cable, Aerial Bundled Cable, jpcable99, PE Insulated ABC Cable