33kv S11 Type off-Circuit Tap Changing Electronic Transformers

China 
                        33kv S11 Type off-Circuit Tap Changing Electronic Transformers
                      manufacture and supplier

33kv S11 Type off-Circuit Tap Changing Electronic Transformers image

Get Latest Price Request a quote

Quick Details

33kv S11 Type off-Circuit Tap Changing Electronic Transformers

S11 Type Transformer

Silverstone Electric

OD

Power Frequency

Power Transformer

ISO9001-2000, ISO9001

Separated Winding Transformer

Oil-immersed Type Transformer

Core-type Transformer

Three

Power, Instrument, Lighting, Rectifier

Gray,Green or Customized

Silverstone Electric

Pallet / Wooden Case / Container

Refer to Drawings

China

8504220000

Product Details

33kV S11 Type Off-circuit Tap Changing Transformers
1. Low loss, therefore significantly energy-saving. The average no-load loss is 35% lower, and the load loss 10~20% lower, than
Prescribed by the present National standard GB/T 6451.
2. The core laminations are made up from imported high-quality cold-rolled grain-oriented silicon steel sheets with miter joints
And without punched holes, and are stacked without the upper yoke sheets in place. After stacking, the core is pressed
Integrally and finally glued together by epoxy resin on the cut edges, so that the three limbs and the upper and lower yokes are
Bonded together into a rigid, vertically straightened entity, together with the plate-type upper and lower frame.
3. Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly, thus
Reducing the temperature rise of the windings as a whole as well as the hot-spot temperature rise, prolonging the service life
Of transformers.
4. The regulating winding is a separate winding, apart from the high voltage main winding. In this way, total ampere-turn balance
Between windings can be obtained irrespective of the tapping position; And the axial electrodynamic force during short circuit
Can be much reduced, thus upgrading the short circuit withstand capability of the transformer as a whole. All the windings are
Perfectly dried before assembly. The radial clearances between windings and between low voltage winding and core are filled
With pre-dried vertical spacers and insulating cylinders in such a way that the windings are tightly together radially with
Practically ‘zero’ allowance between them.
5. The windings of one phase are assembled into an integral phase block before placing onto the core. The low voltage winding is
Wound directly on strong thick paper cylinder. Vertical spacer strips are provided in spaces between windings and outside the
Outermost winding. The radial dimensions of all windings are kept within strict tolerance, so that a rigid winding phase block
Are obtained, capable of withstanding all the radial short-circuit forces encountered in service, and the possibility of buckling
Of the inner winding is obviated. Axially, the height of all windings is kept within close tolerance. Horizontal spacers between
Discs of a winding are pre-densified. The assembled winding phase black are pressed up and down by single support and
Pressure plates after careful adjustment of the heights of individual windings. Axial pressures are co-ordinated with the
Calculated short circuit force, so that the capability of the transformer to withstand axial short-circuit force is much increased.
6. The winding manufacture, winding assembly, and core and winding assembly work are all proceeded in totally closed clean
Rooms inside workshops. The cleanliness and temperature stability requirement of the area are the same as that required for
The manufacture of 500kV class transformers. The final vapor phase drying of the core and coil assembly is practically a further
Cleaning process.
7. Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams. The core and coil
Assembly is fixed in the tank, being positioned against the tank at six sides rigidly, such that there can be no displacement of
The assembly due to impacts during transport. Three-dimensional impact recorders are installed on transformers during
Transport to detect whether or not unacceptable impact force has been experienced and displacement of the core and coil
Assembly occurred during transportation. If not, lifting of the core and coil assembly out of the tank is not necessary. Flat cover
Permits the bushings to be mounted in a vertical posi

We are China 33kv S11 Type off-Circuit Tap Changing Electronic Transformers manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Amorphous Transformer Products

Sczb10-250~2500kVA 11kv on-Load Tap-Changing Distribution Transformer

Three-Phase Two-Winding 33kv off-Circuit Tap Changing Power Transformers

132kv Three Phase Tap Changer Power Transformers

Three Phase Pad Mount Dead Front Transformer Enclosure

11kv Sz11 Type on-Load Tap Changing Transformer

Manufacturer 11kv 630~2500kVA Distribution Transformers

Popular Dry Transformer Products

Sbk-300kVA Three-Phase Isolation Transformer 380V to 480V Dry Type Transformer

630~3150kVA 11kv Dry Type Power-Cast Transformers

Laminated Transformer Core for Power Transformer, Dry Transformer, Oil Transformer Assembly, ISO Standard

Dry Type Medium Voltage Distribution Transformers

Fully Assembled Transformer Core for Power Transformer, Dry Transformer, Oil Transformer, ISO Standard

High Quality DIN Bushing Flange for Electronic Transformer, Dry Transformer

Popular Power Transformer Products

Three Phase Pad Mounted Compact Type Transformer

Quick Response Transformer Parts of 417A Nylon Clamp Bushing With High Quality

NJREC Electrical  Parts of  U70BLP Fog Type Toughened Glass Insulator

Three Phase Tap Changer Power 132kv Transformers

Amorphous Alloy Oil-Immersed Distribution Transformer

Rectifier Special Transformer 11kv 33kv

Popular silverstone-electric Products

250-2500kVA 11kv on-Load Tap-Changer Distribution Transformer

Heat Shrink Cable Joint Hv Cable Termination Kit Cable Connector

High Voltage Shunt Capacitor Bank 11kv 200kVA

Hot Dipped Galvanized DIN 741 Malleable Wire Rope Clips

110kv and Above Rectifier Special Transformer

11kv Scb10-630~3150kVA Distribution Transformer

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION