Quick Details
Product Details
• Designed and manufactured to meet or exceed the requirements of IEC 62271
• Accommodates many customer specific requirements where they differ from IEC
• Silicone insulators with minimum of 25mm/kV creepage
• Plated HDHC copperwork for longevity of life
• Available in 12/15.5 kV, 24 kV and 36 kV voltage ranges
• Standard current ratings of up to 1250 A
• Short time withstand current of 25 kA rms for 3 seconds with 62.5 kA peak
• Standard fault make capacity of 3 kA rms with 7.5 kA peak
• Compact and robust construction
• Suitable for horizontal and vertical mounting
• Suitable for mounting pole top (above the line) or underslung (below the line)
Accessories
• Low level operating handle, high level hookstick mechanism or Independent Manual Spring (IMS) operating mechanism
• 10k A rms 25k A peak fault make capacity when combined with IMS mechanism
• Load break devices with breaking capacity of 630 A for on-load use
• Can be fitted with motor drive/RTU for remote operation
• Earth blades rated at 25 kA 3 sec for fitting to either side
• Self-latching shootbolt on hookstick mechanism can be fitted with safety lock flap for lockoff and point of isolation
• Mounting steelwork to suit single or double pole construction
• Can be fitted with drop out expulsion fuses to form a combination switch fuse
Main Technical Specification
Sheet 1
| No. | Item | Unit | Data | |||
| 1 | Rated voltage | kV | 12 | 24 | 36 | |
| 2 | Rated frequency | Hz | 50/60 | |||
| 3 | Rated current | A | 200/400/630 | |||
| 4 | Rated short circuit withstand current (1S) | kA | 20 | |||
| 5 | Rated peak withstand current (1S) | kA | 50 | |||
| 6 | Rated making current | kA | 31.5-50 | |||
| 7 |
Rated insulation level(HV) |
lightning impulse | kV |
75/85 | 125/145 | 170/195 |
| Power frequency withstand | 45 | 55/75 | 75/100 | |||
| 8 |
Rated short circuit breaking capacity cos. Φ(0.7) Without maintenance of contacts |
—————————— | ||||
| – for active circuits |
20 breakings | A |
630 | 630 | 400 | |
| 30 breakings | 400 | 400 | 300 | |||
| 40 breakings | 300 | 300 | 250 | |||
| 50 breakings | 250 | 250 | 170 | |||
| 75 breakings | 170 | 170 | 160 | |||
| 120 breakings | 110 | 110 | 110 | |||
| 200 breakings | 65 | 65 | 65 | |||
| 280 breakings | 50 | 50 | 50 | |||
Sheet 2
| No. | Item | Unit | Data | ||
| 1 | Rated voltage | kV | 12 | 24 | 36 |
| 9 | For ring circuits breaking capacity | A | 630 | 400 | 250 |
| 10 | Rated breaking capacity of transformer | A | 50 | ||
| 11 | Rated breaking capacity of cable charging | A | 11 | ||
| 12 | Rated breaking capacity of earthing fault | A | 56 | ||
We are China Gang Operated Air Break Switches manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Air Break Switch Products
Overhead 33kv Mv Gang Opearated 630A ABS Air Break Switches
Disconnector Air Break Switch on Load Break Switch
33kv Pole Mounted Three Phase Air Break Switch with Polymer Bushing and Operation Stick
Popular Isolator Switch Products
High -Voltage Isolate Switch 24kv 1250A
Dead End Clamp for ACSR Conductor Compression Type
High -Voltage Isolate Switch 12kv 1000A
Switch Disconnector Manual Operations, Load-Break Disconnector Switches
Popular Outdoor Break Switch Products
High Voltage Outdoor Air Break Switch
Popular silverstone-electric Products
11kv Step Voltage Regulator Voltage Stabilizer
Step Voltage Regulator 11kv Voltage Transformer
Optical Fiber Post Composite Insulator
33kv Type Sc (B) 10-50~2500kVA Distribution Transformers
Cast Post Bushing Epoxy Resin Insulators
Copper Plated Steel Flat Bar Earthing Bar
Tags: Air Break Switch, Isolator Switch, Outdoor Break Switch, silverstone-electric