34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer

China 
                        34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer
                      manufacture and supplier

34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer image

Get Latest Price Request a quote

Quick Details

34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer

34.5/0.433kV

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

OEI Power

Wooden Case

IEC IEEE

China Nanyang

8535309000

Product Details

Center Break Isolator and double Break Isolator

 

These disconnectors are , no load switching devices
which physically isolate the lines. They are designed for
horizontal outdoor application and can also be designed
for vertical installation. For earthing and closing of
switchyard portions of the installation, the earthing
switches are provided on disconnector. If required.

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

We are China 34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

High-Voltage Disconnector Switch 21kv

Stainless Steel Grounding Wire Barrel

33kv Outdoor Pole Mounted ABS Load Air Break Switch

36kv 1250A Load Isolators

High -Voltage Isolate Switch 12kv 630A

High Quality Cross-Arm Composite Insulator for High Voltage

Popular jgtrade1 Products

Channel Supporters Type Mgj, Group B

Dimension Test for Strain Cable Tie 3.6X300mm:

Parallel Clamp

Cut Resistance Gloves, Grade 3hppe + Dyneemagrey 7-11

Polymer Fuse Cutout, Drop out Fuses 24 Kv 100A

Polymer Fuse Cutout, Drop out Fuses 35kv 200A

Popular Rotary Switch Products

12kv 630A Load Isolators

DC Electroscope

24kv 3 Phase Outdoor Switch Disconnector

Gsy High Voltage Electroscope

Gang Operated Air Break Switches

Lug, 2 Hole 4/0

Popular Switch Disconnector Products

Outdoor High Voltage Disconnecting Switch/ Isolator Power

12kv, 1250A Disconnecting Switch with Operation Rod Which Is Fixed with Insulator

Jw-126 Outdoor Mounted Three - Poles High Voltage Isolating Switch

Disconnecor 24kv Disconnector Switch

15kv Group Operated Air Break Switch

Disconnect Switch 145 Kv, 40 Ka, 3150 a