Gang Operated Air Break Switches

China 
                        Gang Operated Air Break Switches
                      manufacture and supplier

Gang Operated Air Break Switches image

Get Latest Price Request a quote

Quick Details

Gang Operated Air Break Switches

GIA GIT

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

Carton

China

Product Details


The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

We are China Gang Operated Air Break Switches manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

Disconnector Switch 40.5kv

Overhead 33kv Mv Gang Opearated 630A ABS Air Break Switches

High-Voltage Disconnector Switch 24kv

24kv Outdoor Pole Mounted Load Disconnector Switch

High-Voltage Disconnector Switch 33kv

33kv/69kv Outdoor High Voltage Three Phase Isolator Disconnector Switch

Popular jgtrade1 Products

12kv Expilsion Fuse Fuseholders

Bolt Guardacabo Eye Angular 5/8 "X 12"

Outdoor 3 Phase 30kv 33kv 35kv 36kv Disconnector / Isolating Switch Model Gw4

High -Voltage Isolate Switch 35kv 6000A

Polymer Fuse Cutout 24kv 100A

Gw4 Outdoor High Voltage 33kv 35kv 400A 630A 1000A 1250A Three Phase Isolator

Popular Rotary Switch Products

Disconnecor 24kv Disconnector Switch

High Voltage 15 Kv Disconnect Isolator Switch /Disconnector Switch

Electroscope

12kv Load Isolators

12kv Load Isolators

High-Voltage Fuse for The Protection of Power Capacitor

Popular Switch Disconnector Products

30kv Link Stick Operated Air Break Switch Including Crossarm

12kv Load Isolators

DC Electroscope

Electrical Equipment Supplies Drop-out Types Ceramic Fuses of High Voltage

Outdoor Single Pole Fused Recloser by-Pass Switches 11kv 900A

AC System Disconnect Switch for Power System

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION