Disconnecor Switch 12kv

China 
                        Disconnecor Switch 12kv
                      manufacture and supplier

Disconnecor Switch 12kv image

Get Latest Price Request a quote

Quick Details

Disconnecor Switch 12kv

IST-12/400

Oei Power

IEC IEEE

Manual

Ist

Single Throw-in

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

OEIpower

Cartons Pallets Wooden Case

IEC IEEE

China

8535309000

Product Details


 
Type IST off-load switchs are suitable for use in tropical zone, with a maximum ambient temperature of approximately 40
degrees Centigrade and an average temperature of approximately 28 degrees Centigrade with high humidity and heavy rainfall.
The preferred operational altitude is up to 1800 m above sea level.

S.No DESCRIPTION UNITS BIDDER OFFERED VALUE
1. Rated Voltage KV 12 KV
2. Frequency Hz 50 Hz
3 Rated continuous current A 630
4 Impulse withstand voltage to ground KV 95
5 Impulse withstand voltage across gaps KV 110
6 Dry one-minute power frequency withstand voltage to ground KV 35
 
7 Dry one minute power frequency withstand voltage across gap KV 45
8 Wet one minute power frequency withstand voltage to ground      KV 30
9 Limits of radio interference 10KV  and 1000 K.C/Sec   250  uV
10 Temperature rise at rated current (max.)        30oC at 50oC ambient
11 Dimensions and mechanical ,Electrical
values Of Polymer Insulator
   
12 Leaking distance  mm      508 (minimum)
13 Dry arcing distance    mm 210 (minimum)
14 Cantilever strength     kg 400 
15 Tensile strength kg 1000
16 Compressive strength  kg 5400
17 Tensile proof test load      kg 700
18 Dry power frequency flashover      KV 85 
19 Wet power frequency flashover      KV 55 
20 Dry one-minute power frequency withstand KV 70
21 Wet one-minute power frequency withstand KV 45
22 Impulse flash over positive      KV 115 
23 Impulse flashover negative      KV 140
24 Power frequency puncture voltage  KV 150  

1.0                       Scope & applications
 
1.1      The  pole-mounted Line Sectionalizer / Disconnector are open type, air insulated switch. The make and Break switching operation are performed at "zero system voltage." in "OFF LOAD"   condition, only for the isolation of the faulty circuits for the protection of 11 KV Distribution lines,   Transformers, Capacitors, Cables,  etc, from high transient lightening and surge Voltages.
 
1.2      The assembly of Gang operated three phase Pole Mounted Line Sectionalizer are supplied as a      single unit with single pole mounting arrangement. The unit are facilitate the installation of the   assembly on both sides (left or right) of the pole to operate and install the operating handle in      accordance with site conditions.    
 
2.0      System / conditions
 
i)                   Nominal system voltage                                    11 KV
ii)                 Highest system voltage                                     12 KV
iii)               Highest voltage for equipment                                 12 KV
iv)               BIL                                                     95 KV
v)                 Phases                                                 3 
vi)               Frequency                                           50 Hz
vii)             Rated Short circuit level of the system                     18 KA (1 second)
viii)           System Earthing: 11 KV Star point / Neutral solidly grounded at Pole / PMT:
 
3.0      Climatic conditions
 
i)                   Maximum ambient air temperature                          50oC
ii)                 Maximum daily average temperature                   45oC
iii)               Minimum ambient air temperature                           0oC
iv)               Maximum sun temperature on exposed Horizontal surface   60oC
v)                 Highest solar radiation intensity                               1000 W/m2
vi)               Maximum relative humidity                              95 %
vii)             Annual rain fall:                                                              20 to 60 mm in 2 to 4                                                           showers
viii)           Altitude                                                       Sea-level
ix)               Location                                                       Sea Coast (Interior is                                                   Semi-Desert).
x)                 Pollution                                           Severe marine pollution on                                                account of windblown                                                            sand and dust with salt                                                       content and salt laden                                                             spray and mist. Washing                                                 action by rain is negligible,                                                as rainfall is scanty.
 
4.0     Ratings and characteristics for line Sectionalizer
 
4.1      The Gang Operated pole mounted 11 kv Line Sectionalizer have the following ratings and characteristics based on 50 deg. C ambient temperature:
 
i)                               Nominal voltage                                               11 KV
ii)                             Maximum design voltage                                                 12 KV
iii)                           Rated continuous current                                              630  Amps
iv)                           Impulse withstand voltage to ground                              95 KV
v)                             Impulse withstand voltage across gaps                              110 KV
vi)                           Dry one-minute power frequency withstand voltage to ground       35 KV
vii)                         Dry one minute power frequency withstand voltage across gap          45 KV
viii)  Wet one minute power frequency withstand voltage to ground        30 KV
ix)                           Limits of radio interference 10KV  and 1000 K.C/Sec                250  uV
x)                             Temperature rise at rated current (max.)                                      30oC at 50oC ambient
 
 
4.2      Polymer insulator
 
The mechanical and electrical characteristics of the Polymeric insulator are as under:
 
 
 
 
 
4.2.1   Dimensions and mechanical values
 
i)                   Leaking distance                                        508 mm  (minimum)
ii)                 Dry arcing distance                                    210 mm  (minimum)
iii)               Cantilever strength                                     400  kg
iv)               Tensile strength                                          1000 kg
v)                 Compressive strength                                        5400 kg
vi)               Tensile proof test load                                      700  kg
                
4.2.2   Electrical values
 
i)                   Dry power frequency flashover                               85  KV
ii)                 Wet power frequency flashover                              55  KV
iii)               Dry one-minute power frequency withstand                   70  KV
iv)               Wet one-minute power frequency withstand                  45  KV
v)                 Impulse flash over positive                                   115  KV
vi)               Impulse flashover negative                               140  KV
vii)             Power frequency puncture voltage                          150  KV
 
 
5.0      Constructional features
The three pole disconnectors are mainly designed for a vertical mounting. The following elements could be changed or incorporated:
– Fuseholder.
– Earthing connection with locking device to prevent the connection to earth when the disconnector is closed or to close the device when the earth is connected.
– The earthing disconnector can be placed in the entrance or exit of the main switch.
– The earth disconnector is operating by means of an independent control.
– The operating axis could be placed at left or  right side.
– The operating axis could be extending until 250, 420,500, 750 or 1000mm, these extensions includes a support to avoid it bend down.
– The outdoor units are provided with different drills to permit the direct fixing to a post or to a frame previously fix to a post.

We are China Disconnecor Switch 12kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

ANSI Strain Insulators for Lines

High Voltage 33kv Isolator Current 2000A with Earth Switch

High -Voltage Isolate Switch 24kv 800A

11kv Load Isolators

Outdoor 3 Phase 30kv 33kv 35kv 36kv Disconnector / Isolating Switch Model Gw4

30kv Link Stick Operated Air Break Switch Including Crossarm

Popular Isolator Products

Suspension Porcelain Insulator High Voltage Insulator U160blp

Isolating Disconnector Switch Gw19-12 Indoor 11kv 12kv Medium Voltage 400A

Glass Insulator Suspension High Voltage IEC Standard

Wholesale Electronics Electrical Fuse Cutout Switch 11kv

Polymeric 12kv 10ka Gapless Zinc Oxide Lightning Arrester with Mounting Bracket

Hangzhou High Voltage Ceramics Drop out Fuse 33kv 24kv 11kv

Popular jgtrade1 Products

Outdoor Single Pole Fused Recloser by-Pass Switches 15kv

15kv 100A-200A Electrical Porcelain Drop-out Fuse Cutout

Ball Pull

Fuse Links Mv Type J Slotted (200 AMPS)

Gang Insulator 24kv

Cross-Plate Anchors

Popular Switch Products

High Voltage Handle Rotary Isolating Switch

Gw16 Hangzhou Outdoor Substation Semi Pantograph Vertical Operation Disconnector

Low-Voltage Fuse Switch for Cable Distribution and Power Supply Systems

Knife Micro Electric Switch, Hkia Switch

End-Caps for Tubular Bus-Bar Type Mgf

Mv Fuse Unit 415V 660V 400A 80ka

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION